Isotope specific resolution recovery image reconstruction in high resolution PET imaging.

Abstract:

PURPOSE:Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. METHODS:In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. RESULTS:The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. CONCLUSIONS:Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

journal_name

Med Phys

journal_title

Medical physics

authors

Kotasidis FA,Angelis GI,Anton-Rodriguez J,Matthews JC,Reader AJ,Zaidi H

doi

10.1118/1.4870985

subject

Has Abstract

pub_date

2014-05-01 00:00:00

pages

052503

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • An introduction to molecular imaging in radiation oncology: a report by the AAPM Working Group on Molecular Imaging in Radiation Oncology (WGMIR).

    abstract::Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acqui...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4819818

    authors: Munley MT,Kagadis GC,McGee KP,Kirov AS,Jang S,Mutic S,Jeraj R,Xing L,Bourland JD

    更新日期:2013-10-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • A water phantom controller for automated acquisition of linac beam parameters.

    abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596414

    authors: Schmid MG,Morris RL

    更新日期:1989-01-01 00:00:00

  • Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

    abstract:PURPOSE:Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13031

    authors: Ghammraoui B,Badal A,Glick SJ

    更新日期:2018-06-03 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00

  • Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

    abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477415

    authors: Shepard DM,Earl MA,Li XA,Naqvi S,Yu C

    更新日期:2002-06-01 00:00:00

  • Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.

    abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3355933

    authors: Balocco S,Camara O,Vivas E,Sola T,Guimaraens L,Gratama van Andel HA,Majoie CB,Pozo JM,Bijnens BH,Frangi AF

    更新日期:2010-04-01 00:00:00

  • High-speed photography during ultrasound illustrates potential therapeutic applications of microbubbles.

    abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2133718

    authors: Postema M,van Wamel A,ten Cate FJ,de Jong N

    更新日期:2005-12-01 00:00:00

  • Study of dosimetry consistency for kilovoltage x-ray beams.

    abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598448

    authors: Ma CM,Li XA,Seuntjens JP

    更新日期:1998-12-01 00:00:00

  • High-resolution fiber-optic dosimeters for microbeam radiation therapy.

    abstract:PURPOSE:A high resolution, water equivalent, optical and passive x-ray dosimeter has been constructed using plastic scintillator and optical fiber. This dosimeter has a peak edge-on spatial resolution of 100 μm in one dimension, with a 10 μm resolution dosimeter under investigation. The dosimeter design has a potential...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12209

    authors: Archer J,Li E,Petasecca M,Lerch M,Rosenfeld A,Carolan M

    更新日期:2017-05-01 00:00:00

  • Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

    abstract::In this paper, the authors review the field of resolution modeling in positron emission tomography (PET) image reconstruction, also referred to as point-spread-function modeling. The review includes theoretical analysis of the resolution modeling framework as well as an overview of various approaches in the literature...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4800806

    authors: Rahmim A,Qi J,Sossi V

    更新日期:2013-06-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597800

    authors: Xu Z,Li H,Almond PR,Guan TY

    更新日期:1996-03-01 00:00:00

  • Response of tissue-equivalent ionization chamber to 15-MeV neutrons.

    abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594310

    authors: Barschall HH,Goldberg E

    更新日期:1977-03-01 00:00:00

  • ALTIS: A fast and automatic lung and trachea CT-image segmentation method.

    abstract:PURPOSE:The automated segmentation of each lung and trachea in CT scans is commonly taken as a solved problem. Indeed, existing approaches may easily fail in the presence of some abnormalities caused by a disease, trauma, or previous surgery. For robustness, we present ALTIS (implementation is available at http://lids....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13773

    authors: Sousa AM,Martins SB,Falcão AX,Reis F,Bagatin E,Irion K

    更新日期:2019-11-01 00:00:00

  • Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion.

    abstract::Use of dynamic multileaf collimation (DMLC) for intensity modulated radiation therapy (IMRT) is accelerating. Delivery systems have the ailment of interleaf leakage (IL). This is compounded by the inefficiency of IMRT delivery, estimated to be a factor of 5 for DMLC. With IL on the order of 4%, it is possible to deliv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388216

    authors: Klein EE,Low DA

    更新日期:2001-08-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597412

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-10-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • A method for physically based radiotherapy optimization with intelligent tissue weight determination.

    abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1428756

    authors: Jones L,Hoban P

    更新日期:2002-01-01 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.

    abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14433

    authors: Burger K,Urban T,Dombrowsky AC,Dierolf M,Günther B,Bartzsch S,Achterhold K,Combs SE,Schmid TE,Wilkens JJ,Pfeiffer F

    更新日期:2020-10-01 00:00:00

  • The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.

    abstract:PURPOSE:Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12295

    authors: Contijoch F,Stayman JW,McVeigh ER

    更新日期:2017-07-01 00:00:00

  • SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735542

    authors: Sheth N,Chen Y,Yang J

    更新日期:2012-06-01 00:00:00

  • An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.

    abstract::We have developed a new method for optimization in intensity modulated radiation therapy (IMRT) that makes use of simulated dynamics in a classical system of interacting particles. An analogy is drawn between intensity profile optimization in IMRT and relaxation to the equilibrium configuration in a dynamic system. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1528179

    authors: Hou Q,Wang J,Chen Y,Galvin JM

    更新日期:2003-01-01 00:00:00

  • Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12318

    authors: Fatnassi C,Boucenna R,Zaidi H

    更新日期:2017-07-01 00:00:00

  • Photon dose calculation incorporating explicit electron transport.

    abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597611

    authors: Yu CX,Mackie TR,Wong JW

    更新日期:1995-07-01 00:00:00

  • Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl.

    abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3036117

    authors: Arvanitis CD,Bohndiek SE,Blakesley J,Olivo A,Speller RD

    更新日期:2009-01-01 00:00:00

  • The properties of the ultramicrocylindrical ionization chamber for small field used in stereotactic radiosurgery.

    abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350437

    authors: Vahc YW,Chung WK,Park KR,Lee JY,Lee YH,Kwon O,Kim S

    更新日期:2001-03-01 00:00:00