Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

Abstract:

:The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various depths and field sizes (5 × 5, 10 × 10, 15 × 15, 20 × 20 and 30 × 30 cm2 ) using a PTW 31006 ionization chamber and a scanning water tank. By comparing the calculated and measured PDD results, it was seen that for larger field sizes the deviation between the calculated and measured PDD was smaller. Deviations between the calculated and measured results were found to be higher in the build-up regions of the 6 and 15 MV photon beams. For the statistical analyses, t-tests were performed using the measured and calculated PDDs for each field size but showed insignificant deviations for the 6 and 15 MV photon beams. The mean t-test values are 0.952 and 0.970 for the 6 and 15 MV photon beams, respectively. The difference between the calculated and measured PDD is within the acceptable range according to the ICRU reports (ICRU Report No. 24, 1976). We conclude that accurate calculation of the PDD using the measured TMR data is possible, which is useful as the PDD cannot be measured directly.

journal_name

Med Phys

journal_title

Medical physics

authors

Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

doi

10.1118/1.4740131

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4628-4629

issue

7Part3

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Correcting TG 119 confidence limits.

    abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12759

    authors: Kearney V,Solberg T,Jensen S,Cheung J,Chuang C,Valdes G

    更新日期:2018-03-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • SU-E-I-32: Sterile Radiation Reduction Gloves May Be Contraindicated in Fluoroscopically Guided Interventions.

    abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734747

    authors: Pasciak A,Neveu M,Sriharan A,Balius A,Jones A

    更新日期:2012-06-01 00:00:00

  • A general algorithm for calculation of recombination losses in ionization chambers exposed to ion beams.

    abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962483

    authors: Christensen JB,Tölli H,Bassler N

    更新日期:2016-10-01 00:00:00

  • Accuracy of Dose-Volume Metric Calculation for Small Volume Radiosurgery Targets.

    abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14645

    authors: Stanley DN,Covington E,Liu H,Alexandrian A,Cardan R,Bridges D,Thomas EM,Fiveash JB,Popple R

    更新日期:2020-12-09 00:00:00

  • Cumulative sum quality control for calibrated breast density measurements.

    abstract:PURPOSE:Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3250842

    authors: Heine JJ,Cao K,Beam C

    更新日期:2009-12-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom.

    abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13952

    authors: Siewerdsen JH,Uneri A,Hernandez AM,Burkett GW,Boone JM

    更新日期:2020-02-01 00:00:00

  • Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

    abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4951732

    authors: Pogue BW,Paulsen KD,Samkoe KS,Elliott JT,Hasan T,Strong TV,Draney DR,Feldwisch J

    更新日期:2016-06-01 00:00:00

  • Simple design for a Styrofoam cutter.

    abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594206

    authors: Sorensen A,Goshaw L

    更新日期:1975-11-01 00:00:00

  • SU-E-T-582: Assessment of Improved Critical Structure Sparing Using Biologically- Based Optimization for Volumetric Modulated Arc Therapy of Head and Neck Cancer.

    abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735671

    authors: Dogan N,Wu Y

    更新日期:2012-06-01 00:00:00

  • The value of nodal information in predicting lung cancer relapse using 4DPET/4DCT.

    abstract:PURPOSE:There is evidence that computed tomography (CT) and positron emission tomography (PET) imaging metrics are prognostic and predictive in nonsmall cell lung cancer (NSCLC) treatment outcomes. However, few studies have explored the use of standardized uptake value (SUV)-based image features of nodal regions as pre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4926755

    authors: Li H,Becker N,Raman S,Chan TC,Bissonnette JP

    更新日期:2015-08-01 00:00:00

  • Development and evaluation of a case-based reasoning classifier for prediction of breast biopsy outcome with BI-RADS lexicon.

    abstract::Approximately 70-85% of breast biopsies are performed on benign lesions. To reduce this high number of biopsies performed on benign lesions, a case-based reasoning (CBR) classifier was developed to predict biopsy results from BI-RADS findings. We used 1433 (931 benign) biopsy-proven mammographic cases. CBR similarity ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1501140

    authors: Bilska-Wolak AO,Floyd CE Jr

    更新日期:2002-09-01 00:00:00

  • Technical note: development of a tidal volume surrogate that replaces spirometry for physiological breathing monitoring in 4D CT.

    abstract:PURPOSE:Spirometry exhibits baseline drift and frequent measurement errors so it cannot be used by itself to provide tidal volume-based image sorting or breathing motion modeling. Other breathing surrogates, in this study an abdominal bellows system, are drift free but do not measure tidal volume. Simultaneously using ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284282

    authors: Werner R,White B,Handels H,Lu W,Low DA

    更新日期:2010-02-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735184

    authors: Chofor N,Poppe B,Harder D

    更新日期:2012-06-01 00:00:00

  • Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.

    abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14326

    authors: Son J,Shin D,Kim T,Park S,Rah JE

    更新日期:2020-09-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • Combined use of transverse and scout computed tomography scans to localize radioactive seeds in an interstitial brachytherapy implant.

    abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598548

    authors: Yue N,Chen Z,Bond JE,Son YH,Nath R

    更新日期:1999-04-01 00:00:00

  • SU-E-J-106: Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer.

    abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734942

    authors: Pirozzi S,Horvat M,Piper J,Nelson A

    更新日期:2012-06-01 00:00:00

  • SU-E-T-159: Sensitivity of in Line Real Time Scintillating Fiber Detectors for External Beam Treatment Verification and Patient Safety.

    abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735217

    authors: Izaguirre EW,Price SG,Smajlovic S,Yaddanapudi S,Wooten H,Mutic S

    更新日期:2012-06-01 00:00:00

  • Pharmacokinetic modeling.

    abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597047

    authors: Strand SE,Zanzonico P,Johnson TK

    更新日期:1993-03-01 00:00:00

  • Automated lung segmentation of diseased and artifact-corrupted magnetic resonance sections.

    abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2214165

    authors: Sensakovic WF,Armato SG 3rd,Starkey A,Caligiuri P

    更新日期:2006-09-01 00:00:00

  • Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.

    abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3355933

    authors: Balocco S,Camara O,Vivas E,Sola T,Guimaraens L,Gratama van Andel HA,Majoie CB,Pozo JM,Bijnens BH,Frangi AF

    更新日期:2010-04-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • Advanced statistical techniques applied to comprehensive FTIR spectra on human colonic tissues.

    abstract:PURPOSE:Colon cancer is a major public health problem due to its high disease rate and death toll worldwide. The use of FTIR microscopy in the field of cancer diagnosis has become attractive over the past 20 years. In the present study, the authors investigated the potential of FTIR microscopy to define spectral change...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298013

    authors: Zwielly A,Mordechai S,Sinielnikov I,Salman A,Bogomolny E,Argov S

    更新日期:2010-03-01 00:00:00

  • Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification.

    abstract:PURPOSE:The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS:A 100 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3476459

    authors: Hyer DE,Hintenlang DE

    更新日期:2010-09-01 00:00:00