Abstract:
:For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic modeling and of pharmacokinetic data reduction, leading to cumulated activities. In this paper different types of models are characterized as "empirical," "analytical," and "compartmental" pharmacokinetic models. There remains a pressing need for quantitative studies in man for a proper understanding of the pharmacokinetics of MAb. Pharmacokinetic modeling of radiolabeled MAb in vivo has relied on relatively limited studies in man and complementary detailed measurements in animals. In either case, any model chosen for analysis of such data is inevitably based on measurements of limited accuracy and precision as well as assumptions regarding human physiology. Very few macroscopic compartmental pharmacokinetic models for MAb, have been tested over a range of conditions to determine their predictive ability. Extracorporeal immunoadsorption represents one approach for drastically altering the biokinetics of antibody distribution, and may serve to validate a given pharmacokinetic model. In addition to macroscopic modeling, the microscopic evaluation of the time-dependent distribution of radiolabeled MAb in tissues is of utmost importance for a proper understanding of the kinetics and radiobiologic effect. Many tumors do not exhibit homogeneous uptake. A mathematical understanding of that distribution is thus essential for accurate tumor dosimetry estimates. This review summarizes methodologies for pharmacokinetic modeling, critically reviews specific pharmacokinetic models and demonstrates the capability of modeling for predictive calculations of altered pharmacokinetics, emphasizing its use in dosimetric calculations.
journal_name
Med Physjournal_title
Medical physicsauthors
Strand SE,Zanzonico P,Johnson TKdoi
10.1118/1.597047subject
Has Abstractpub_date
1993-03-01 00:00:00pages
515-27issue
2 Pt 2eissn
0094-2405issn
2473-4209journal_volume
20pub_type
杂志文章,评审相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12425
更新日期:2017-09-01 00:00:00
abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2161404
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13804
更新日期:2019-11-01 00:00:00
abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1533749
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813299
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3555035
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897610
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:For the past two decades, high-Z nanoparticles have been of high interest to improve the therapeutic outcomes of radiation therapy, especially for low-energy X-rays. Monte Carlo (MC) simulations have been used to evaluate the boost of dose deposition induced by Auger electrons near the nanoparticle surface, by ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14576
更新日期:2020-11-04 00:00:00
abstract::Depth dose distributions for a d(14)Be neutron beam, measured separately for total and gamma absorbed dose, are presented for nine tissue substitutes and for two field sizes. These data are used to examine methods to transform depth dose curves from one material to another. Best results are found when the local depths...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595695
更新日期:1985-05-01 00:00:00
abstract::Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were rem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3070547
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.12810
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:Texture analysis (TA) has proved to be useful to distinguish different tissues and disease states using magnetic resonance imaging (MRI). TA has been successfully applied clinically to improve identification of abnormalities in the brain, liver, and bone and, more recently, has been used to enhance the specific...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3622605
更新日期:2011-09-01 00:00:00
abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168433
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. METHODS:Eleven patients with unresectable disease at the tonsil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928485
更新日期:2015-09-01 00:00:00
abstract::A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduct...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596747
更新日期:1991-01-01 00:00:00
abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2404617
更新日期:2007-01-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595686
更新日期:1985-09-01 00:00:00
abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597725
更新日期:1996-08-01 00:00:00
abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373402
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735070
更新日期:2012-06-01 00:00:00
abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2335489
更新日期:2006-09-01 00:00:00
abstract::In proton therapy, it is important to evaluate the field irradiated with protons and the deposited dose distribution in a patient's body. Positron emitters generated through fragmentation reactions of target nuclei can be used for this purpose. By detecting the annihilation gamma rays from the positron emitters, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712572
更新日期:2007-05-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597228
更新日期:1994-12-01 00:00:00
abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597307
更新日期:1994-03-01 00:00:00
abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2825622
更新日期:2008-02-01 00:00:00