Determination of the initial beam parameters in Monte Carlo linac simulation.

Abstract:

:For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated dose distributions with the measured dose distributions through a trial and error process. This process is very time consuming and requires a lot of Monte Carlo simulation experience and computational resources. In this paper, we propose an easy, efficient, and accurate method for the determination of the initial beam parameters. We hypothesize that (1) for one type of linacs, the geometry and material of major components of the treatment head are the same; the only difference is the phase space parameters of the initial electron beam incident on the target, and (2) most linacs belong to a limited number of linac types. For each type of linacs, Monte Carlo treatment planning system (MC-TPS) vendors simulate the treatment head and calculate the three-dimensional (3D) dose distribution in water phantom for a grid of initial beam energies and radii. The simulation results (phase space files and dose distribution files) are then stored in a data library. When a MC-TPS user tries to model their linac which belongs to the same type, a standard set of measured dose data is submitted and compared with the calculated dose distributions to determine the optimal combination of initial beam energy and radius. We have applied this method to the 6 MV beam of a Varian 21EX linac. The linac was simulated using EGSNRC/BEAM code and the dose in water phantom was calculated using EGSNRC/DOSXYZ. We have also studied issues related to the proposed method. Several common cost functions were tested for comparing measured and calculated dose distributions, including chi2, mean absolute error, dose difference at the penumbra edge point, slope of the dose difference of the lateral profile, and the newly proposed Kappaalpha factor (defined as the fraction of the voxels with absolute dose difference less than alpha%). It was found that the use of the slope of the lateral profile difference or the difference of the penumbra edge points may lead to inaccurate determination of the initial beam parameters. We also found that in general the cost function value is very sensitive to the simulation statistical uncertainty, and there is a tradeoff between uncertainty and specificity. Due to the existence of statistical uncertainty in simulated dose distributions, it is practically impossible to determine the best energy/radius combination; we have to accept a group of energy/radius combinations. We have also investigated the minimum required data set for accurate determination of the initial beam parameters. We found that the percent depth dose curves along or only a lateral profile at certain depth for a large field size is not sufficient and the minimum data set should include several lateral profiles at various depths as well as the central axis percent depth dose curve for a large field size.

journal_name

Med Phys

journal_title

Medical physics

authors

Aljarrah K,Sharp GC,Neicu T,Jiang SB

doi

10.1118/1.2168433

subject

Has Abstract

pub_date

2006-04-01 00:00:00

pages

850-8

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • Model-based optoacoustic inversion with arbitrary-shape detectors.

    abstract:PURPOSE:Optoacoustic imaging enables mapping the optical absorption of biological tissue using optical excitation and acoustic detection. Although most image-reconstruction algorithms are based on the assumption of a detector with an isotropic sensitivity, the geometry of the detector often leads to a response with spa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589141

    authors: Rosenthal A,Ntziachristos V,Razansky D

    更新日期:2011-07-01 00:00:00

  • Scatter-glare correction using a convolution algorithm with variable weighting.

    abstract::Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596088

    authors: Naimuddin S,Hasegawa B,Mistretta CA

    更新日期:1987-05-01 00:00:00

  • The optimization of signal detectability in digital fluoroscopy.

    abstract::An optimization analysis of digital fluoroscopy has been carried out using (signal/noise)2/dose as a figure of merit. Three signal detection tasks have been considered: (i) small iodine-containing blood vessels; (ii) regions of fat; and (iii) microcalcifications. The effects of x-ray beam filtration and kilovoltage on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595130

    authors: Zamenhof RG

    更新日期:1982-09-01 00:00:00

  • The properties of the ultramicrocylindrical ionization chamber for small field used in stereotactic radiosurgery.

    abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350437

    authors: Vahc YW,Chung WK,Park KR,Lee JY,Lee YH,Kwon O,Kim S

    更新日期:2001-03-01 00:00:00

  • Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

    abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14421

    authors: Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

    更新日期:2020-10-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Monte Carlo based IMRT dose verification using MLC log files and R/V outputs.

    abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2208916

    authors: Luo W,Li J,Price RA Jr,Chen L,Yang J,Fan J,Chen Z,McNeeley S,Xu X,Ma CM

    更新日期:2006-07-01 00:00:00

  • Dose in the buildup region outside the primary beam.

    abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595508

    authors: Horton JL

    更新日期:1984-05-01 00:00:00

  • SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4.

    abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734794

    authors: Kapadia A,Samei E,Harrawood B,Sahbaee P,Chawla A,Tan Z,Brady D

    更新日期:2012-06-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Computer-aided diagnosis in the era of deep learning.

    abstract::Computer-aided diagnosis (CAD) has been a major field of research for the past few decades. CAD uses machine learning methods to analyze imaging and/or nonimaging patient data and makes assessment of the patient's condition, which can then be used to assist clinicians in their decision-making process. The recent succe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13764

    authors: Chan HP,Hadjiiski LM,Samala RK

    更新日期:2020-06-01 00:00:00

  • Development of a silicon diode detector for skin dosimetry in radiotherapy.

    abstract:PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12469

    authors: Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

    更新日期:2017-10-01 00:00:00

  • A randomization approach to handling data scaling in nuclear medicine.

    abstract:PURPOSE:In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431573

    authors: Bai C,Conwell R,Kindem J

    更新日期:2010-06-01 00:00:00

  • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

    abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1381549

    authors: Liu Y,Liu H,Wang Y,Wang G

    更新日期:2001-07-01 00:00:00

  • SU-D-BRA-02: An Extended Time-Variant Seasonal Autoregressive Model-Based Prediction for Irregular Breathing Motion Tracking.

    abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734680

    authors: Ichiji K,Homma N,Sakai M,Narita Y,Takai Y,Yoshizawa M

    更新日期:2012-06-01 00:00:00

  • "SABER": A new software tool for radiotherapy treatment plan evaluation.

    abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3497152

    authors: Zhao B,Joiner MC,Orton CG,Burmeister J

    更新日期:2010-11-01 00:00:00

  • The influence of field strength and different clinical breast MRI protocols on the outcome of texture analysis using foam phantoms.

    abstract:PURPOSE:Texture analysis (TA) has proved to be useful to distinguish different tissues and disease states using magnetic resonance imaging (MRI). TA has been successfully applied clinically to improve identification of abnormalities in the brain, liver, and bone and, more recently, has been used to enhance the specific...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3622605

    authors: Waugh SA,Lerski RA,Bidaut L,Thompson AM

    更新日期:2011-09-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • Wedge-shaped dose distributions by computer-controlled collimator motion.

    abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594440

    authors: Kijewski PK,Chin LM,Bjärngard BE

    更新日期:1978-09-01 00:00:00

  • MO-D-213CD-04: 4D X-Ray DSA and 4D Fluoroscopy.

    abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735797

    authors: Mistretta C

    更新日期:2012-06-01 00:00:00

  • Characterization of distensibility, plaque burden, and composition of the atherosclerotic carotid artery using magnetic resonance imaging.

    abstract:PURPOSE:Arterial distensibility is a marker that can measure vessel wall functional and structural changes resulting from atherosclerosis with applications including estimation of mechanical properties of the wall. We sought to assess the feasibility of using magnetic resonance imaging (MRI) to include wall distensibil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754302

    authors: Canton G,Hippe DS,Sun J,Underhill HR,Kerwin WS,Tang D,Yuan C

    更新日期:2012-10-01 00:00:00

  • SU-E-T-283: Carbon Ion Therapy Innovations in Dosimetry and Dose Delivery.

    abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735351

    authors: Cernica G,Mun S

    更新日期:2012-06-01 00:00:00

  • Validation of Monte Carlo calculated surface doses for megavoltage photon beams.

    abstract::Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1829401

    authors: Abdel-Rahman W,Seuntjens JP,Verhaegen F,Deblois F,Podgorsak EB

    更新日期:2005-01-01 00:00:00

  • Scatter rejection by electronic collimation.

    abstract::An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595940

    authors: Plenkovich D,Sorenson JA,Kruger RA

    更新日期:1986-03-01 00:00:00

  • Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

    abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12677

    authors: Shan J,An Y,Bues M,Schild SE,Liu W

    更新日期:2018-01-01 00:00:00

  • Optimized radial and angular positions in Monte Carlo modeling.

    abstract::In Monte Carlo simulations of light transport in tissues, a grid system is set up to score physical quantities. This study of cylindrically symmetrical problems found that the optimized radial and angular positions for the averaged physical quantities in each grid element are off-center. The error of the extrapolated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597351

    authors: Wang L,Jacques SL

    更新日期:1994-07-01 00:00:00

  • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

    abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207212

    authors: Tzedakis A,Perisinakis K,Raissaki M,Damilakis J

    更新日期:2006-07-01 00:00:00

  • Sci-Fri AM: Imaging - 05: Cone-beam computed tomography for breast biopsy analysis: Simulations.

    abstract:PURPOSE:To determine the feasibility and potential utility of cone beam CT on breast biopsies. METHODS:CBCT simulations were done with a setup which emulates an MX-20 digital specimen radiography system (Faxitron X-Ray Corporation, Chicago, IL), albeit a DQE = 1 was assumed. The phantom consisted of a 5mm diameter cyl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740191

    authors: Laamanen C,LeClair R

    更新日期:2012-07-01 00:00:00

  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00