Abstract:
:In Monte Carlo simulations of light transport in tissues, a grid system is set up to score physical quantities. This study of cylindrically symmetrical problems found that the optimized radial and angular positions for the averaged physical quantities in each grid element are off-center. The error of the extrapolated physical quantities at the light-incidence point using the centered radial positions is up to 14.3%.
journal_name
Med Physjournal_title
Medical physicsauthors
Wang L,Jacques SLdoi
10.1118/1.597351subject
Has Abstractpub_date
1994-07-01 00:00:00pages
1081-3issue
7eissn
0094-2405issn
2473-4209journal_volume
21pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4863510
更新日期:2014-03-01 00:00:00
abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2989019
更新日期:2008-11-01 00:00:00
abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397458
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3355933
更新日期:2010-04-01 00:00:00
abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595393
更新日期:1983-07-01 00:00:00
abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597008
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract::Two side-by-side energy windows, one at the photopeak and one at lower energy, are sometimes employed in quantitative SPECT studies. We measured the count-rate losses at moderately high activities of 131I for two multihead Anger cameras in such a dual-window-acquisition mode by imaging a decaying source composed of tw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598162
更新日期:1998-01-01 00:00:00
abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875688
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928148
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903292
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. METHODS:A multisized imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4923172
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615059
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4823795
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. METHODS:The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3218767
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12598
更新日期:2017-12-01 00:00:00
abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598971
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735058
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Recently, brain tumor segmentation has made important progress. However, the quality of manual labels plays an important role in the performance, while in practice, it could vary greatly and in turn could substantially mislead the learning process and decrease the accuracy. We need to design a mechanism to comb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14480
更新日期:2020-09-24 00:00:00
abstract::We have previously investigated a method of high-energy x-ray spectral reconstruction from transmission data by direct resolution of a matrix system. This technique uses the spectral vectorial algebra formalism. The resolution has previously been tested on a 12 MV photon beam. To extend and to test the validity of the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597998
更新日期:1997-05-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract:PURPOSE:Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4962472
更新日期:2016-10-01 00:00:00
abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597739
更新日期:1996-09-01 00:00:00
abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598598
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12805
更新日期:2018-04-01 00:00:00
abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597768
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12944
更新日期:2018-07-01 00:00:00
abstract::The purpose of this study is to develop a 4D inverse planning strategy capable of controlling the appearance of the implanted fiducial(s) in segmented IMRT fields for cine MV or combined MV/kV image-guided IMRT. This work is focused on enhancing the visibility of the implanted fiducial(s) in 4D IMRT inverse planning, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3121425
更新日期:2009-06-01 00:00:00