Development of a silicon diode detector for skin dosimetry in radiotherapy.

Abstract:

PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercial diodes for such applications are with water equivalent depths ranging from 0.5 to 0.8 mm. In this study, we investigate a new detector for skin dosimetry based on a silicon epitaxial diode, referred to as the skin diode. METHOD:The skin diode is manufactured on a thin epitaxial layer and packaged using the "drop-in" technology. It was characterized in terms of percentage depth dose, dose linearity, and dose rate dependence, and benchmarked against the Attix ionization chamber. The response of the skin diode in the build-up region of the percentage depth dose (PDD) curve of a 6 MV clinical photon beam was investigated. Geant4 radiation transport simulations were used to model the PDD in order to estimate the water equivalent measurement depth (WED) of the skin diode. Measured output factors using the skin diode were compared with the MOSkin detector and EBT3 film at 10 cm depth and at surface at isocenter of a water equivalent phantom. The intrinsic angular response of the skin diode was also quantified in charge particle equilibrium conditions (CPE) and at the surface of a solid water phantom. Finally, the radiation hardness of the skin diode up to an accumulated dose of 80 kGy using photons from a Co-60 gamma source was evaluated. RESULTS:The PDD curve measured with the skin diode was within 0.5% agreement of the equivalent Geant4 simulated curve. When placed at the phantom surface, the WED of the skin diode was estimated to be 0.075 ± 0.005 mm from Geant4 simulations and was confirmed using the response of a corrected Attix ionization chamber placed at water equivalent depth of 0.075 mm, with the measurement agreement to within 0.3%. The output factor measurements at 10 cm depth were within 2% of those measured with film and the MOSkin detector down to a field size of 2 × 2 cm2 . The dose-response for all detector samples was linear and with a repeatability within 0.2%. The skin diode intrinsic angular response showed a maximum deviation of 8% at 90 degrees and from 0 to 60 degree is less than 5%. The radiation sensitivity reduced by 25% after an accumulated dose of 20 kGy but after was found to stabilize. At 60 kGy total accumulated dose the response was within 2% of that measured at 20 kGy total accumulated dose. CONCLUSIONS:This work characterizes an innovative detector for in vivo and real-time skin dose measurements that is based on an epitaxial silicon diode combined with the Centre for Medical Radiation Physics (CMRP) "drop-in" packaging technology. The skin diode proved to have a water equivalent depth of measurement of 0.075 ± 0.005 mm and the ability to measure doses accurately relative to reference detectors.

journal_name

Med Phys

journal_title

Medical physics

authors

Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

doi

10.1002/mp.12469

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

5402-5412

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

44

pub_type

杂志文章
  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Combined use of transverse and scout computed tomography scans to localize radioactive seeds in an interstitial brachytherapy implant.

    abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598548

    authors: Yue N,Chen Z,Bond JE,Son YH,Nath R

    更新日期:1999-04-01 00:00:00

  • SU-E-I-57: CT Dose Metrics: What Are We Tracking.

    abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734773

    authors: Guild J,Arbique G,Blackburn T,Gallet J,Anderson J

    更新日期:2012-06-01 00:00:00

  • High-speed photography during ultrasound illustrates potential therapeutic applications of microbubbles.

    abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2133718

    authors: Postema M,van Wamel A,ten Cate FJ,de Jong N

    更新日期:2005-12-01 00:00:00

  • A general model of microcirculatory blood flow effects in gradient sensitized MRI.

    abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597170

    authors: Kennan RP,Gao JH,Zhong J,Gore JC

    更新日期:1994-04-01 00:00:00

  • The tracks of the Compton effect.

    abstract::The observation of scattered radiations of larger wavelength than the primary had been repeatedly rejected or explained away by many researchers, including Compton. After years of vacillations, he recognized the effect named after him and was the first to develop a quantal equation predicting the wavelength of scatter...

    journal_title:Medical physics

    pub_type: 传,历史文章,杂志文章

    doi:10.1118/1.595046

    authors: del Regato JA

    更新日期:1981-11-01 00:00:00

  • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

    abstract::The purpose of this study is to develop a 4D inverse planning strategy capable of controlling the appearance of the implanted fiducial(s) in segmented IMRT fields for cine MV or combined MV/kV image-guided IMRT. This work is focused on enhancing the visibility of the implanted fiducial(s) in 4D IMRT inverse planning, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3121425

    authors: Ma Y,Lee L,Keshet O,Keall P,Xing L

    更新日期:2009-06-01 00:00:00

  • An inexpensive kVp penetrameter.

    abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595716

    authors: Netto TG,Cameron JR

    更新日期:1985-03-01 00:00:00

  • An investigation into the robustness of dynamically collimated proton therapy treatments.

    abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14208

    authors: Smith BR,Hyer DE,Culberson WS

    更新日期:2020-08-01 00:00:00

  • Poster - Thurs Eve-32: Dose errors related to the treatment couch.

    abstract::Modern radiotherapy linacs often use carbon fibre for their couch tops due to its radio translucent properties. Beam attenuation by the couches is often ignored during planning and MU calculation. This work examines beam attenuation and loss of "skin sparing" (dose build up region) when various photon beams transit ei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965951

    authors: Niedbala M,Nyiri B,Gerig L

    更新日期:2008-07-01 00:00:00

  • Magnetic resonance spectroscopy.

    abstract::The nuclear magnetic resonance phenomenon has given rise to both magnetic resonance imaging, which yields morphologic data, and magnetic resonance spectroscopy (MRS), which yields chemical data. In humans these data are derived principally from the resonances of the hydrogen nucleus in the low molecular weight compoun...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2975225

    authors: Prost RW

    更新日期:2008-10-01 00:00:00

  • On the conditioning of basis materials and its impact on multi-material decomposition based spectral imaging in photon-counting CT.

    abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14708

    authors: Tang X,Ren Y

    更新日期:2021-01-07 00:00:00

  • Measurements of magnetism-related forces and torque moments affecting medical instruments, implants, and foreign objects during magnetic resonance imaging at all degrees of freedom.

    abstract::We designed a novel force/torque moment transducer with six degrees of freedom. This new sensor is used for measuring the forces and torque moments exerted by static magnetic resonance imaging (MRI) fields on various medical implants, instruments, and ballistic shell fragments. To determine the location of strongest e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597853

    authors: Planert J,Modler H,Vosshenrich R

    更新日期:1996-06-01 00:00:00

  • Quantification of body-torso-wide tissue composition on low-dose CT images via automatic anatomy recognition.

    abstract:PURPOSE:Quantification of body composition plays an important role in many clinical and research applications. Radiologic imaging techniques such as Dual-energy X-ray absorptiometry (DXA), magnetic resonance imaging (MRI), and computed tomography (CT) imaging make accurate quantification of the body composition possibl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13373

    authors: Liu T,Udupa JK,Miao Q,Tong Y,Torigian DA

    更新日期:2019-03-01 00:00:00

  • SU-E-T-619: A Network-Flow Solution Approach to VMAT Treatment Plan Optimization.

    abstract:PURPOSE:To add mathematical rigor to the merging phase of the recently published two-stage VMAT optimization method called VMERGE. Using an exact merging method, we are able to better characterize the tradeoff between delivery efficiency and dose quality. METHODS:VMERGE begins with an IMRT plan that uses 180 equi-spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735709

    authors: Salari E,Craft D

    更新日期:2012-06-01 00:00:00

  • Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning.

    abstract:PURPOSE:To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. METHODS:Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using pena...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12146

    authors: Engberg L,Forsgren A,Eriksson K,Hårdemark B

    更新日期:2017-06-01 00:00:00

  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00

  • Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy.

    abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4917481

    authors: van de Ven WJ,Hu Y,Barentsz JO,Karssemeijer N,Barratt D,Huisman HJ

    更新日期:2015-05-01 00:00:00

  • A restricted angular scattering model for electron penetration in dense media.

    abstract::A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596747

    authors: McLellan J,Sandison GA,Papiez L,Huda W

    更新日期:1991-01-01 00:00:00

  • Measurement of primary bremsstrahlung spectrum from an 8-MeV linear accelerator.

    abstract::The bremsstrahlung spectrum from an 8-MeV linear accelerator has been measured using a NaI(T1) spectrometer system. The spectrum shows a low-energy cutoff at 0.4 MeV and the maximum photon energy to be approximately 6% greater than the nominal energy. The maximum emission of energy fluence was 1.6 and 1.8 MeV for meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594221

    authors: Levy LB,Waggener RG,Wright AE

    更新日期:1976-05-01 00:00:00

  • SU-E-T-462: Calculation of Prescribed Dose for Permanent Implant with Cs-131 Using LQ Equation including Resensitization.

    abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735551

    authors: Luo W,Aryal P,Randall M

    更新日期:2012-06-01 00:00:00

  • Fast IMRT with narrow high energy scanned photon beams.

    abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615059

    authors: Andreassen B,Strååt SJ,Holmberg R,Näfstadius P,Brahme A

    更新日期:2011-08-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • Sampling methods for a matrix ionization chamber system.

    abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596829

    authors: van Herk M,Bijhold J,Hoogervorst B,Meertens H

    更新日期:1992-03-01 00:00:00

  • Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation.

    abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597672

    authors: Spirou SV,Chui CS

    更新日期:1996-01-01 00:00:00

  • ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy.

    abstract:PURPOSE:New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863482

    authors: Hanlon J,Chell E,Firpo M,Koruga I

    更新日期:2014-02-01 00:00:00

  • Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

    abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1869652

    authors: Cho Y,Moseley DJ,Siewerdsen JH,Jaffray DA

    更新日期:2005-04-01 00:00:00

  • SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

    abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734816

    authors: Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

    更新日期:2012-06-01 00:00:00

  • A doorless entry system for high-energy radiation therapy rooms.

    abstract::A doorless entry system has been designed for use in high-energy radiation therapy rooms. The doorless entry improves patient access, safety and throughput, increases the physical safety for the radiation therapists, and avoids the significant cost of heavy shielding doors. The design meets concerns relating to radiat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598181

    authors: Dawson DJ,Wissing WW,Tonks RE

    更新日期:1998-02-01 00:00:00