Sci-Fri AM: Imaging - 05: Cone-beam computed tomography for breast biopsy analysis: Simulations.

Abstract:

PURPOSE:To determine the feasibility and potential utility of cone beam CT on breast biopsies. METHODS:CBCT simulations were done with a setup which emulates an MX-20 digital specimen radiography system (Faxitron X-Ray Corporation, Chicago, IL), albeit a DQE = 1 was assumed. The phantom consisted of a 5mm diameter cylinder with a length of 5mm, made up of a homogeneous 50:50 mixture of fibrous and fatty tissue. Small cancerous spheres (lesions) with diameters ranging from 5 to 500 μm were embedded. Projections were acquired at magnification 5 using 26 kV-0.3 mA-3.8 sec beams. Images were reconstructed using a varied number of projections (50, 100, 150, 300). Values of contrast and SNR were calculated between the lesions and nearby regions. Noise was estimated by generating 10 images for each task. Scatter was found to be negligible. RESULTS:The 50 μm spheres were only visible when at least 150 projections were used, but the 100 μm ones were visible regardless of the number. SNR increased with the number of projections, whereas contrast was insensitive. For ≥100 μm spheres contrast ranged from 0.26 on the outer radial edge to 0.28 nearer the center. The SNRs for 100 μm spheres were above 5 for reconstructions composed of ≥100 projections. Cancerous lesions within a fibrous biopsy may be detectable. CONCLUSIONS:The findings from this simulation study suggest that CBCT for breast biopsy characterization via the MX-20 system could be of potential use to see structures on the order of 100 μm.

journal_name

Med Phys

journal_title

Medical physics

authors

Laamanen C,LeClair R

doi

10.1118/1.4740191

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4641

issue

7Part4

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Clinical Target Volume Segmentation for Stomach Cancer by Stochastic Width Deep Neural Network.

    abstract:PURPOSE:Precise segmentation of clinical target volume (CTV) is the key to stomach cancer radiotherapy. We proposed a novel stochastic width - deep neural network (SW-DNN) for better automatically contouring stomach CTV METHODS: SW-DNN was an end-to-end approach, of which the core component was a novel SW mechanism tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14733

    authors: Xu L,Hu J,Song Y,Bai S,Yi Z

    更新日期:2021-01-27 00:00:00

  • A beam intensity monitor for the Loma Linda cancer therapy proton accelerator.

    abstract::A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596636

    authors: Coutrakon G,Miller D,Kross BJ,Anderson DF,DeLuca P Jr,Siebers J

    更新日期:1991-07-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Direction modulated brachytherapy (DMBT) for treatment of cervical cancer: A planning study with 192 Ir, 60 Co, and 169 Yb HDR sources.

    abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12598

    authors: Safigholi H,Han DY,Mashouf S,Soliman A,Meigooni AS,Owrangi A,Song WY

    更新日期:2017-12-01 00:00:00

  • Verification of IMRT dose distributions using a water beam imaging system.

    abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1413519

    authors: Li JS,Boyer AL,Ma CM

    更新日期:2001-12-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy.

    abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598930

    authors: Zavgorodni SF

    更新日期:2000-04-01 00:00:00

  • Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system.

    abstract::A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596643

    authors: Liew SC,Hasegawa BH

    更新日期:1991-09-01 00:00:00

  • The dosimetric properties of an intraoperative radiation therapy applicator system for a Mevatron-80.

    abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596338

    authors: Nelson CE,Cook R,Rakfal S

    更新日期:1989-09-01 00:00:00

  • A 4 x 500 mm2 cloverleaf detector system for in vivo bone lead measurement.

    abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436973

    authors: Fleming DE,Mills CE

    更新日期:2007-03-01 00:00:00

  • Pulmonary nodule detection in CT images based on shape constraint CV model.

    abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4907961

    authors: Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu L

    更新日期:2015-03-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • Technical Note: ADAM PETer - An anthropomorphic, deformable and multimodality pelvis phantom with positron emission tomography extension for radiotherapy.

    abstract:OBJECTIVE:To develop an anthropomorphic, deformable and multimodal pelvis phantom with positron emission tomography extension for radiotherapy (ADAM PETer). METHODS:The design of ADAM PETer was based on our previous pelvis phantom (ADAM) and extended for compatibility with PET and use in 3T magnetic resonance imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14597

    authors: Gillmann C,Homolka N,Johnen W,Runz A,Echner G,Pfaffenberger A,Mann P,Schneider V,Hoffmann AL,Troost EGC,Koerber SA,Kotzerke J,Beuthien-Baumann B

    更新日期:2020-11-18 00:00:00

  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners.

    abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3426000

    authors: Mathieu KB,McNitt-Gray MF,Zhang D,Kim HJ,Cody DD

    更新日期:2010-08-01 00:00:00

  • On the conditioning of basis materials and its impact on multi-material decomposition based spectral imaging in photon-counting CT.

    abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14708

    authors: Tang X,Ren Y

    更新日期:2021-01-07 00:00:00

  • Prior data assisted compressed sensing: a novel MR imaging strategy for real time tracking of lung tumors.

    abstract:PURPOSE:Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4885960

    authors: Yip E,Yun J,Wachowicz K,Heikal AA,Gabos Z,Rathee S,Fallone BG

    更新日期:2014-08-01 00:00:00

  • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool.

    abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3271107

    authors: Iori M,Cagni E,Paiusco M,Munro P,Nahum AE

    更新日期:2010-01-01 00:00:00

  • MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735777

    authors: Andriole K

    更新日期:2012-06-01 00:00:00

  • Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging.

    abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595995

    authors: Röschmann P

    更新日期:1987-11-01 00:00:00

  • Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4896101

    authors: Dzyubak O,Kincaid R,Hertanto A,Hu YC,Pham H,Rimner A,Yorke E,Zhang Q,Mageras GS

    更新日期:2014-10-01 00:00:00

  • Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments.

    abstract:PURPOSE:To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. METHODS:Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729738

    authors: Mancuso GM,Fontenot JD,Gibbons JP,Parker BC

    更新日期:2012-07-01 00:00:00

  • The properties of the ultramicrocylindrical ionization chamber for small field used in stereotactic radiosurgery.

    abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350437

    authors: Vahc YW,Chung WK,Park KR,Lee JY,Lee YH,Kwon O,Kim S

    更新日期:2001-03-01 00:00:00

  • A time-domain wavelet-based approach for fluorescence diffuse optical tomography.

    abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431571

    authors: Ducros N,Da Silva A,Dinten JM,Seelamantula CS,Unser M,Peyrin F

    更新日期:2010-06-01 00:00:00

  • Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

    abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12332

    authors: Gunay G,Luu MH,Moelker A,van Walsum T,Klein S

    更新日期:2017-07-01 00:00:00

  • Estimation of organ and effective dose due to Compton backscatter security scans.

    abstract:PURPOSE:To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. METHODS:Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4718680

    authors: Hoppe ME,Schmidt TG

    更新日期:2012-06-01 00:00:00

  • Radiative transport in the delta-P1 approximation for semi-infinite turbid media.

    abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828184

    authors: Seo I,Hayakawa CK,Venugopalan V

    更新日期:2008-02-01 00:00:00

  • Four-dimensional (4D) PET/CT imaging of the thorax.

    abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1809778

    authors: Nehmeh SA,Erdi YE,Pan T,Pevsner A,Rosenzweig KE,Yorke E,Mageras GS,Schoder H,Vernon P,Squire O,Mostafavi H,Larson SM,Humm JL

    更新日期:2004-12-01 00:00:00

  • Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques.

    abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892606

    authors: Grimes J,Celler A

    更新日期:2014-09-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00