Technical Note: ADAM PETer - An anthropomorphic, deformable and multimodality pelvis phantom with positron emission tomography extension for radiotherapy.

Abstract:

OBJECTIVE:To develop an anthropomorphic, deformable and multimodal pelvis phantom with positron emission tomography extension for radiotherapy (ADAM PETer). METHODS:The design of ADAM PETer was based on our previous pelvis phantom (ADAM) and extended for compatibility with PET and use in 3T magnetic resonance imaging (MRI). The formerly manually manufactured silicon organ surrogates were replaced by three-dimensional (3D) printed organ shells. Two intraprostatic lesions, four iliac lymph node metastases and two pelvic bone metastases were added to simulate prostate cancer as multifocal and metastatic disease. Radiological properties [computed tomography (CT) and 3T MRI] of cortical bone, bone marrow and adipose tissue were simulated by heavy gypsum, a mixture of Vaseline and K2 HPO4 and peanut oil, respectively. For soft tissues, agarose gels with varying concentrations of agarose, gadolinium (Gd) and sodium fluoride (NaF) were developed. The agarose gels were doped with patient-specific activity concentrations of a Fluorine-18 labelled compound and then filled into the 3D printed organ shells of prostate lesions, lymph node and bone metastases. The phantom was imaged at a dual energy CT and a 3T PET/MRI scanner. RESULTS:The compositions of the soft tissue surrogates are the following (given as mass fractions of agarose[w%]/NaF[w%]/Gd[w%]): Muscle (4/1/0.027), prostate (1.35/4.2/0.011), prostate lesions (2.25/4.2/0.0085), lymph node and bone metastases (1.4/4.2/0.025). In all imaging modalities, the phantom simulates human contrast. Intraprostatic lesions appear hypointense as compared to the surrounding normal prostate tissue in T2-weighted MRI. The PET signal of all tumors can be localized as focal spots at their respective site. Activity concentrations of 12.0 kBq/mL (prostate lesion), 12.4 kBq/mL (lymph nodes) and 39.5 kBq/mL (bone metastases) were measured. CONCLUSION:The ADAM PETer pelvis phantom can be used as multimodal, anthropomorphic model for CT, 3T-MRI and PET measurements. It will be central to simulate and optimize the technical workflow for the integration of PET/MRI-based radiation treatment planning of prostate cancer patients.

journal_name

Med Phys

journal_title

Medical physics

authors

Gillmann C,Homolka N,Johnen W,Runz A,Echner G,Pfaffenberger A,Mann P,Schneider V,Hoffmann AL,Troost EGC,Koerber SA,Kotzerke J,Beuthien-Baumann B

doi

10.1002/mp.14597

subject

Has Abstract

pub_date

2020-11-18 00:00:00

eissn

0094-2405

issn

2473-4209

pub_type

杂志文章
  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.

    abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298010

    authors: Karnik VV,Fenster A,Bax J,Cool DW,Gardi L,Gyacskov I,Romagnoli C,Ward AD

    更新日期:2010-02-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Thermal regulation of tightly packed solid-state photodetectors in a 1 mm(3) resolution clinical PET system.

    abstract:PURPOSE:Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. P...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903889

    authors: Freese DL,Vandenbroucke A,Innes D,Lau FW,Hsu DF,Reynolds PD,Levin CS

    更新日期:2015-01-01 00:00:00

  • Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    abstract:PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938066

    authors: Liu Y,Yin FF,Rhee D,Cai J

    更新日期:2016-01-01 00:00:00

  • Are we doing any good by doing really well? (Where's the Bacon?).

    abstract::Francis Bacon, who with Rene Decartes laid the intellectual foundations for Western science in the seventeenth century, asserted that the purpose of all knowledge is "action in the production of works for ... the relief of man's estate." We assess briefly several aspects of a few of the current efforts directed to the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1555493

    authors: Herbert D

    更新日期:2003-04-01 00:00:00

  • Penumbral measurements in water for high-energy x rays.

    abstract::Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ioniza...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595963

    authors: Dawson DJ,Schroeder NJ,Hoya JD

    更新日期:1986-01-01 00:00:00

  • An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy.

    abstract::To improve beam penetration into a head allowing the treatment of deeper seated tumors, two neutron collimators were built sequentially and tested for use in the clinical boron neutron capture therapy (BNCT) program at the epithermal neutron irradiation facility of the Brookhaven Medical Research Reactor. The collimat...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.597772

    authors: Liu HB,Greenberg DD,Capala J,Wheeler FJ

    更新日期:1996-12-01 00:00:00

  • Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.

    abstract:PURPOSE:To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905116

    authors: Ubeda C,Miranda P,Vano E

    更新日期:2015-02-01 00:00:00

  • Recent progress in x-ray stereoscopes.

    abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595365

    authors: Zhang S,King PH,Pang XD

    更新日期:1983-09-01 00:00:00

  • A fast double template convolution isocenter evaluation algorithm with subpixel accuracy.

    abstract:PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imagi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524227

    authors: Winey B,Sharp G,Bussière M

    更新日期:2011-01-01 00:00:00

  • Current status and future perspective of flattening filter free photon beams.

    abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3554643

    authors: Georg D,Knöös T,McClean B

    更新日期:2011-03-01 00:00:00

  • Analysis of generalized rosette trajectory for compressed sensing MRI.

    abstract:PURPOSE:The application of compressed sensing (CS) technology in magnetic resonance imaging (MRI) is to accelerate the MRI scan speed by incoherent undersampling of k-space data and nonlinear iterative reconstruction of MRI images. This paper generalizes the existing rosette trajectories to configure the sampling patte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928152

    authors: Li Y,Yang R,Zhang C,Zhang J,Jia S,Zhou Z

    更新日期:2015-09-01 00:00:00

  • Estimation of the axial wall strains induced by an arterial stenosis at peak flow.

    abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1844432

    authors: Doriot PA,Dorsaz PA

    更新日期:2005-02-01 00:00:00

  • Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.

    abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12944

    authors: Zhang H,Xie J,Xiao S,Zhao X,Zhang M,Shi L,Wang K,Wu G,Sun X,Ye C,Zhou X

    更新日期:2018-07-01 00:00:00

  • Static multileaf collimator for fast-neutron therapy.

    abstract::This paper describes a multileaf collimator, designed to obtain irregularly shaped neutron fields, that fits into an existing fixed field-size collimator system. The shape of the desired portal field is obtained by appropriately setting the position of each leaf of the collimator. The collimator consists of 40 polyeth...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596084

    authors: Chu JC,Bloch P

    更新日期:1987-03-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • SU-E-T-450: An Evaluation Study of Dose Calculation Algorithms for Stereotactic Body Radiation Therapy in Heterogeneous Phantom.

    abstract:PURPOSE:In Stereotactic body radiation therapy (SBRT) higher dose per fraction is delivered to patients and thus the need for an accurate dose computation is further elevated. However under such conditions of small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735539

    authors: Shosha M,Deiab N,Eldib A,Tohamy K

    更新日期:2012-06-01 00:00:00

  • Cascaded systems analysis of noise reduction algorithms in dual-energy imaging.

    abstract::An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general ana...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2826556

    authors: Richard S,Siewerdsen JH

    更新日期:2008-02-01 00:00:00

  • Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction.

    abstract::Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2163247

    authors: Taguchi K,Chiang BS,Hein IA

    更新日期:2006-02-01 00:00:00

  • Dosimetry for 252Cf neutron emitting brachytherapy sources: protocol, measurements, and calculations.

    abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598646

    authors: Rivard MJ

    更新日期:1999-08-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.

    abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2199987

    authors: Melhus CS,Rivard MJ

    更新日期:2006-06-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00

  • SU-E-T-264: New Concrete Designed and Evaluation for Megavoltage X Radiotherapy Facilities (CONTEK-RFH2).

    abstract:PURPOSE:The most common material for shielding is concrete, which can be made using various materials of different densities as aggregates. New techniques in radiotherapy, as IMRT and VMAT, require more monitor units and it is important to develop specifically designed shielding materials. METHODS:Arraela S.L. has dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735331

    authors: Mera M,Pereira L,Mera M,Pereira L,Meilán E,Moral FD,Teijeiro A,Salgado M,Andrade B,Gomez F,Fuentes-Vázquez V,Caruncho J,Medina A

    更新日期:2012-06-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • A correction-based dose calculation algorithm for kilovoltage x rays.

    abstract::Frequent and repeated imaging procedures such as those performed in image-guided radiotherapy (IGRT) programs may add significant dose to radiosensitive organs of radiotherapy patients. It has been shown that kV-CBCT results in doses to bone that are up to a factor of 3-4 higher than those in surrounding soft tissue. ...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3014197

    authors: Ding GX,Pawlowski JM,Coffey CW

    更新日期:2008-12-01 00:00:00

  • Correction of microwave-induced thermistor sensor errors.

    abstract::Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic lea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595261

    authors: Samaras GM,Rosenbloom S,Cheung AY

    更新日期:1983-05-01 00:00:00