Abstract:
PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules based on a shape constraint Chan-Vese (CV) model combined with calculation of the number of blood branches adhered to nodule candidates is proposed to reduce false positive (FP) nodules from candidate nodules. METHODS:The proposed scheme consists of three major stages: (1) Segmentation of lung parenchyma from computed tomography images. (2) Extraction of candidate nodules. (3) Reduction of FP nodules. A gray level enhancement combined with a spherical shape enhancement filter is introduced to extract the candidate nodules and their sphere-like contour regions. FPs are removed by analysis of the typical shape features of nodule candidates based on the CV model using spherical constraint and by investigating the number of blood branches adhered to the candidate nodules. The constrained shapes of CV model are automatically achieved from the extracted candidate nodules. RESULTS:The detection performance was evaluated on 127 nodules of 103 cases including three types of challenging nodules, which are juxta-pleural nodules, juxta-vascular nodules, and ground glass opacity nodules. The free-receiver operating characteristic (FROC) curve shows that the proposed method is able to detect 88% of all the nodules in the data set with 4 FPs per case. CONCLUSIONS:Evaluation shows that the authors' method is feasible and effective for detection of three types of nodules in this study.
journal_name
Med Physjournal_title
Medical physicsauthors
Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu Ldoi
10.1118/1.4907961subject
Has Abstractpub_date
2015-03-01 00:00:00pages
1241-54issue
3eissn
0094-2405issn
2473-4209journal_volume
42pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Intraoperative three-dimensional reconstruction of seed locations during prostate brachytherapy for purposes of immediate computation of radiation dosimetry is an active area of current investigation, including methods which use multiple fluoroscopic projections. A simulation study using seed locations extracted from ...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1707740
更新日期:2004-05-01 00:00:00
abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1949750
更新日期:2005-08-01 00:00:00
abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1470205
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose q...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3561508
更新日期:2011-04-01 00:00:00
abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1869652
更新日期:2005-04-01 00:00:00
abstract::Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measure...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1352579
更新日期:2001-04-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373402
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875688
更新日期:2014-06-01 00:00:00
abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2919724
更新日期:2008-06-01 00:00:00
abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1624755
更新日期:2003-12-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract::The number of intensity modulated radiation therapy (IMRT) procedures is continuously growing worldwide and it is necessary to develop tools for patient specific quality assurance (QA) that avoid using machine time that could be employed in treating additional patients. One way of achieving this goal is to perform a m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2815359
更新日期:2008-01-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for bot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3319498
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:Periprocedural assessment of tissue perfusion by imaging methods could improve outcome control during treatment of peripheral vascular disease. Currently, endovascular revascularization treatments are assessed by planar angiography which only allows for qualitative inspection of blood flow in vessels. In this p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679864
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810940
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of a three-plenoptic camera projection, scintillation-based dosimetry system for measuring three-dimensional (3D) dose distributions of static photon radiation fields. METHODS:Static x-ray photon beams were delivered to a cubic plastic scintillator volume embedded within acrylic ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14213
更新日期:2020-08-01 00:00:00
abstract::Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598606
更新日期:1999-06-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596610
更新日期:1991-09-01 00:00:00
abstract:PURPOSE:Anatomical variations occur during head and neck (H&N) radiotherapy treatment. kV cone-beam computed tomography (CBCT) images can be used for daily dose monitoring to assess dose variations owing to anatomic changes. Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) from CBCT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14387
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:Stray neutron radiation is of concern after radiation therapy, especially in children, because of the high risk it might carry for secondary cancers. Several previous studies predicted the stray neutron exposure from proton therapy, mostly using Monte Carlo simulations. Promising attempts to develop analytical ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829512
更新日期:2013-12-01 00:00:00
abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598219
更新日期:1998-04-01 00:00:00
abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803498
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735665
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431999
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595716
更新日期:1985-03-01 00:00:00