Ray-based approach to skeletal muscle perfusion measurement on interventional x-ray systems.

Abstract:

PURPOSE:Periprocedural assessment of tissue perfusion by imaging methods could improve outcome control during treatment of peripheral vascular disease. Currently, endovascular revascularization treatments are assessed by planar angiography which only allows for qualitative inspection of blood flow in vessels. In this paper, we present a method for periprocedural perfusion estimation based on temporal attenuation curves in skeletal muscles using angiographic C-arm systems. METHODS:The proposed method tackles the loss of spatial depth information which occurs in conventional angiography by combining the acquired angiograms with two additional C-arm rotational soft tissue scans. The area subject to contrast propagation is segmented from the two images that are tomographically reconstructed from the rotational scans and is then used to estimate the spatially averaged temporal contrast attenuation along the x-ray directions from the angiograms. A segmentation method which is tailored to the estimation procedure is applied to limit inaccuracies in the estimation. The accuracy of the method in estimating tissue blood flow in muscular tissue is evaluated in a simulation study using experimental data from CT perfusion acquisitions. RESULTS:Results show that perfusion estimation accuracy is limited owing to spatial inhomogeneity of contrast in muscular tissue and to the presence of vessels along the x-ray directions. Nonetheless, the spatially averaged perfusion quantification allows for improved visual differentiation of normal and hypoperfused tissue in comparison with conventional digital subtraction angiography. CONCLUSIONS:Periprocedural assessment of muscle perfusion through digital subtraction angiography is challenging due to lack of longitudinal information in the planar projections. By including additional 3D information on the anatomy retrieved from rotational soft tissue scans, the visualization and differentiation of normal and hypoperfused areas can be improved.

journal_name

Med Phys

journal_title

Medical physics

authors

Giordano M,Vonken EJ,Bertram M,Mali W,Viergever MA,Neukirchen C

doi

10.1118/1.3679864

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

1190-206

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.

    abstract:PURPOSE:MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons is temperature dependent, the local temperature variation (relative to an initial baseline) may be calculated from time-dependent p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3309439

    authors: Viallon M,Terraz S,Roland J,Dumont E,Becker CD,Salomir R

    更新日期:2010-04-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID.

    abstract:PURPOSE:The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. METHODS:The APS has an active area of 5.4 × 5.4 cm and maximum full frame read-out rate of 20 frame s(-1),...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651632

    authors: Osmond JP,Zin HM,Harris EJ,Lupica G,Allinson NM,Evans PM

    更新日期:2011-11-01 00:00:00

  • Knowledge-based planning for intensity-modulated radiation therapy: A review of data-driven approaches.

    abstract:PURPOSE:Intensity-Modulated Radiation Therapy (IMRT), including its variations (including IMRT, Volumetric Arc Therapy (VMAT), and Tomotherapy), is a widely used and critically important technology for cancer treatment. It is a knowledge-intensive technology due not only to its own technical complexity, but also to the...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13526

    authors: Ge Y,Wu QJ

    更新日期:2019-06-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Investigation of basic imaging properties in digital radiography. 9. Effect of displayed grey levels on signal detection.

    abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595919

    authors: Giger ML,Ohara K,Doi K

    更新日期:1986-05-01 00:00:00

  • Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy.

    abstract:PURPOSE:Stray neutron radiation is of concern after radiation therapy, especially in children, because of the high risk it might carry for secondary cancers. Several previous studies predicted the stray neutron exposure from proton therapy, mostly using Monte Carlo simulations. Promising attempts to develop analytical ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829512

    authors: Pérez-Andújar A,Zhang R,Newhauser W

    更新日期:2013-12-01 00:00:00

  • Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation.

    abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2776255

    authors: Lu HM,Brett R,Engelsman M,Slopsema R,Kooy H,Flanz J

    更新日期:2007-10-01 00:00:00

  • Development of a silicon diode detector for skin dosimetry in radiotherapy.

    abstract:PURPOSE:The aim of in vivo skin dosimetry was to measure the absorbed dose to the skin during radiotherapy, when treatment planning calculations cannot be relied on. It is of particularly importance in hypo-fractionated stereotactic modalities, where excessive dose can lead to severe skin toxicity. Currently, commercia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12469

    authors: Vicoroski N,Espinoza A,Duncan M,Oborn BM,Carolan M,Metcalfe P,Menichelli D,Perevertaylo VL,Lerch MLF,Rosenfeld AB,Petasecca M

    更新日期:2017-10-01 00:00:00

  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • Charged particle transport in magnetic fields in EGSnrc.

    abstract:PURPOSE:To accurately and efficiently implement charged particle transport in a magnetic field in EGSnrc and validate the code for the use in phantom and ion chamber simulations. METHODS:The effect of the magnetic field on the particle motion and position is determined using one- and three-point numerical integrations...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4954318

    authors: Malkov VN,Rogers DW

    更新日期:2016-07-01 00:00:00

  • Magnetic resonance spectroscopy.

    abstract::The nuclear magnetic resonance phenomenon has given rise to both magnetic resonance imaging, which yields morphologic data, and magnetic resonance spectroscopy (MRS), which yields chemical data. In humans these data are derived principally from the resonances of the hydrogen nucleus in the low molecular weight compoun...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2975225

    authors: Prost RW

    更新日期:2008-10-01 00:00:00

  • A framework for defining FLASH dose rate for pencil beam scanning.

    abstract:PURPOSE:To develop a method of (a) calculating the dose rate of voxels within a proton field delivered using pencil beam scanning (PBS), and (b) reporting a representative dose rate for the PBS treatment field that enables correspondence between multiple treatment modalities. This method takes into account the unique s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14456

    authors: Folkerts MM,Abel E,Busold S,Perez JR,Krishnamurthi V,Ling CC

    更新日期:2020-12-01 00:00:00

  • An improved electron energy-loss straggling algorithm for Monte Carlo transport codes.

    abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595500

    authors: Weinhous MS,Nath R

    更新日期:1984-05-01 00:00:00

  • Computerized detection of lung nodules through radiomics.

    abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12331

    authors: Ma J,Zhou Z,Ren Y,Xiong J,Fu L,Wang Q,Zhao J

    更新日期:2017-08-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00

  • Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment.

    abstract:PURPOSE:The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13511

    authors: Ding GX,Zhang Y,Ren L

    更新日期:2019-06-01 00:00:00

  • The effects of the imaging system on the validity limits of the ray-optical approach to phase contrast imaging.

    abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2126207

    authors: Peterzol A,Olivo A,Rigon L,Pani S,Dreossi D

    更新日期:2005-12-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • An anthropomorphic torso section phantom for ultrasonic imaging.

    abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594657

    authors: Madsen EL,Zagzebski JA,Ghilardi-Netto T

    更新日期:1980-01-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • Four-dimensional (4D) PET/CT imaging of the thorax.

    abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1809778

    authors: Nehmeh SA,Erdi YE,Pan T,Pevsner A,Rosenzweig KE,Yorke E,Mageras GS,Schoder H,Vernon P,Squire O,Mostafavi H,Larson SM,Humm JL

    更新日期:2004-12-01 00:00:00

  • Assessing radiation and light field congruence with a video based electronic portal imaging device.

    abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597867

    authors: Luchka K,Chen D,Shalev S,Gluhchev G,Rajapakshe R

    更新日期:1996-07-01 00:00:00

  • Technical Note: Spot characteristic stability for proton pencil beam scanning.

    abstract:PURPOSE:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939663

    authors: Chen CC,Chang C,Moyers MF,Gao M,Mah D

    更新日期:2016-02-01 00:00:00

  • Magnetic cell delivery for peripheral arterial disease: A theoretical framework.

    abstract:PURPOSE:Our aim was to compare different magnet arrangements for magnetic cell delivery to human lower leg arteries and investigate the theoretical targeting efficiency under realistic flow conditions as a possible treatment after angioplasty. Additionally the potential of scaling down or translating the magnetic actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3593363

    authors: Riegler J,Lau KD,Garcia-Prieto A,Price AN,Richards T,Pankhurst QA,Lythgoe MF

    更新日期:2011-07-01 00:00:00