Abstract:
PURPOSE:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. METHODS:A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0-226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. RESULTS:Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. CONCLUSIONS:For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.
journal_name
Med Physjournal_title
Medical physicsauthors
Chen CC,Chang C,Moyers MF,Gao M,Mah Ddoi
10.1118/1.4939663subject
Has Abstractpub_date
2016-02-01 00:00:00pages
777-82issue
2eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1493216
更新日期:2002-08-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4769428
更新日期:2013-01-01 00:00:00
abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3148536
更新日期:2009-07-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1812851
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803498
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14676
更新日期:2020-12-23 00:00:00
abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3442276
更新日期:2010-07-01 00:00:00
abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008428
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903299
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12615
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14557
更新日期:2020-10-28 00:00:00
abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12234
更新日期:2017-07-01 00:00:00
abstract::A new factor for shifting isodoes curves for oblique Co-60 photon beams has been deduced. Like the two other known factors, this shift factor depends on the source-to-surface distance (SSD), the depth dose (D) and the derivative of D with depth. A comparison of corrected dose distributions has been made by using the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594688
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12759
更新日期:2018-03-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4830427
更新日期:2013-12-01 00:00:00
abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1835571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3483784
更新日期:2010-10-01 00:00:00
abstract::Flat-panel imagers consisting of the first large area, self-scanning, pixelated, solid-state arrays made with hydrogenated amorphous silicon (a-Si:H) are under development by the authors for applications in diagnostic x-ray and megavoltage radiotherapy imaging. The arrays, designated by the acronym MASDA for multi-ele...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596802
更新日期:1992-11-01 00:00:00
abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813302
更新日期:2013-08-01 00:00:00
abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2795832
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:The advent of three-dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clini...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13629
更新日期:2019-09-01 00:00:00
abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1617550
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:Dynamic 18 F-FDG PET allows quantitative estimation of cerebral glucose metabolism both at the regional and local (voxel) level. Although sensitive to noise and highly computationally expensive, nonlinear least-squares (NLS) optimization stands as the reference approach for the estimation of the kinetic model p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13366
更新日期:2019-03-01 00:00:00
abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2193689
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:Real-time adaptive planning and treatment has been infeasible due in part to its high computational complexity. There have been many recent efforts to utilize graphics processing units (GPUs) to accelerate the computational performance and dose accuracy in radiation therapy. Data structure and memory access pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4895822
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12795
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00