Abstract:
PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radiologists are busy fighting the coronavirus disease. Furthermore, it is hard to compare current COVID-19 CT segmentation methods as they are developed on different datasets, trained in different settings, and evaluated with different metrics. METHODS:To promote the development of data-efficient deep learning methods, in this paper, we built three benchmarks for lung and infection segmentation based on 70 annotated COVID-19 cases, which contain current active research areas, for example, few-shot learning, domain generalization, and knowledge transfer. For a fair comparison among different segmentation methods, we also provide standard training, validation and testing splits, evaluation metrics and, the corresponding code. RESULTS:Based on the state-of-the-art network, we provide more than 40 pretrained baseline models, which not only serve as out-of-the-box segmentation tools but also save computational time for researchers who are interested in COVID-19 lung and infection segmentation. We achieve average dice similarity coefficient (DSC) scores of 97.3%, 97.7%, and 67.3% and average normalized surface dice (NSD) scores of 90.6%, 91.4%, and 70.0% for left lung, right lung, and infection, respectively. CONCLUSIONS:To the best of our knowledge, this work presents the first data-efficient learning benchmark for medical image segmentation, and the largest number of pretrained models up to now. All these resources are publicly available, and our work lays the foundation for promoting the development of deep learning methods for efficient COVID-19 CT segmentation with limited data.
journal_name
Med Physjournal_title
Medical physicsauthors
Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang Xdoi
10.1002/mp.14676subject
Has Abstractpub_date
2020-12-23 00:00:00eissn
0094-2405issn
2473-4209pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::We applied Monte Carlo methods for the simulation of x-ray scattering in water phantoms. The phantom thickness was varied from 5 to 20 cm, and the monoenergetic incident x rays were varied from 15 to 100 keV. Eight screen pairs and a total absorption system were used as x-ray receptors. We determined the angular, spec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595771
更新日期:1985-03-01 00:00:00
abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597688
更新日期:1996-04-01 00:00:00
abstract:PURPOSE:Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4762814
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966704
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:Cardiac motion is typically not accounted for during pretreatment imaging for central lung and mediastinal tumors. However, cardiac induced tumor motion averages 5.8 mm for esophageal tumors and 3-5 mm for some lung tumors, which can result in positioning errors. Our aim is to reduce both cardiac- and respirato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13670
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12778
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not appl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3598442
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for bot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3319498
更新日期:2010-05-01 00:00:00
abstract::Tissue absorbed dose (D) is a computed result for internal emitters. For fixed geometries, D is calculated by a matrix (S) multiplication of the integrated activity vector (Ã). The last quantity is usually measured by nuclear imaging of activity in various source organs and performing a temporal integration. Ã is the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735750
更新日期:2012-06-01 00:00:00
abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1481520
更新日期:2002-06-01 00:00:00
abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597511
更新日期:1995-07-01 00:00:00
abstract::The NSD equation, D = 1850 x T0.11 x N0.24, is a celebrated transmogrification of Cohen's two well-known collations of data on response to clinical irradiations (3 degrees erythema and 0.90 ablation of skin cancer) in which the relation of D and T is fixed by the data selected by Cohen and the additional constraint th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595034
更新日期:1981-11-01 00:00:00
abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4926551
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS:A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondenc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736204
更新日期:2012-06-01 00:00:00
abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3063544
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:To evaluate dosimetric variations of planning target volume (PTV) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (VMAT). METHODS:Three patients with small (32.0 cm3 ), medium (48.4 cm3 ) and large (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735610
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system. METHODS:A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12767
更新日期:2018-03-01 00:00:00
abstract::Francis Bacon, who with Rene Decartes laid the intellectual foundations for Western science in the seventeenth century, asserted that the purpose of all knowledge is "action in the production of works for ... the relief of man's estate." We assess briefly several aspects of a few of the current efforts directed to the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1555493
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum est...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3676740
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734936
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4831757
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735033
更新日期:2012-06-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1823571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4958677
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905116
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00
abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596495
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12426
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13892
更新日期:2020-01-01 00:00:00