Accuracy of a 3D laser∕camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments.

Abstract:

PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on two groups of patients for whom different patient setup procedures and Sentinel employment conditions were considered. For the first group of 33 patients (FG) no changes to the usual setup procedures were made and a surface extension limited to the treated region was considered. For the second group of 14 patients (SG) the reproducibility of external body surfaces, including body parts not in close proximity to the treatment site, was optimized and a wider surface was captured. In all cases the system accuracy was evaluated comparing registration results from concurrent Sentinel and cone beam CT (CBCT) acquisitions for a total of 192 occasions. External body surfaces, extracted from planning CT studies, were used as reference in both cases, but for SG also surface data captured by Sentinel system at the first treatment were employed. RESULTS:In the 90th percentile of the distributions reporting CBCT and Sentinel registration parameters, absolute differences for FG were less than 6.4 mm and 3.8°. Better performances were observed for SG (≤5.7 mm and 2°). Mean absolute differences between three translation and three rotation parameters of CBCT and Sentinel were: less than 3.5 mm and 2.1° and 3.7 mm and 1.3° in FG for thorax and pelvis, respectively, and less than 2.8 mm and 1° and 2.7 mm and 0.9° for pelvis and thorax, respectively, in SG. No advantage in considering surface data captured by Sentinel as a reference instead of the surface extracted from the planning CT was observed. CONCLUSIONS:The accuracy of Sentinel system in detecting errors is influenced by the extension and reliability of the surface used. When the reproducibility of external body surfaces was optimized differences between CBCT and Sentinel registration parameters resulted less than 5.7 mm and 2° in the 90% of the pelvis and thorax considered cases. No advantage in considering a Sentinel acquisition as reference was observed.

journal_name

Med Phys

journal_title

Medical physics

authors

Pallotta S,Simontacchi G,Marrazzo L,Ceroti M,Paiar F,Biti G,Bucciolini M

doi

10.1118/1.4769428

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

011710

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

    abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477230

    authors: Siebers JV,Lauterbach M,Keall PJ,Mohan R

    更新日期:2002-06-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00

  • SU-E-J-58: Patient-Specific Biomechanical Head and Neck Models for Interfraction Dose Accumulation.

    abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734893

    authors: Santhanam A,Ennis D,Low D,Kupelian P

    更新日期:2012-06-01 00:00:00

  • A novel approach to evaluate spatial resolution of MRI clinical images for optimization and standardization of breast screening protocols.

    abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966704

    authors: Borri M,Scurr ED,Richardson C,Usher M,Leach MO,Schmidt MA

    更新日期:2016-12-01 00:00:00

  • Optimized knot placement for B-splines in deformable image registration.

    abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3609416

    authors: Jacobson TJ,Murphy MJ

    更新日期:2011-08-01 00:00:00

  • Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom.

    abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13952

    authors: Siewerdsen JH,Uneri A,Hernandez AM,Burkett GW,Boone JM

    更新日期:2020-02-01 00:00:00

  • Dead time of an anger camera in dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597008

    authors: Zasadny KR,Koral KF,Swailem FM

    更新日期:1993-07-01 00:00:00

  • Study of dosimetry consistency for kilovoltage x-ray beams.

    abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598448

    authors: Ma CM,Li XA,Seuntjens JP

    更新日期:1998-12-01 00:00:00

  • Thick phosphor screens for on-line portal imaging.

    abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597209

    authors: Wowk B,Shalev S

    更新日期:1994-08-01 00:00:00

  • On the speckle-free nature of photoacoustic tomography.

    abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3187231

    authors: Guo Z,Li L,Wang LV

    更新日期:2009-09-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    abstract:PURPOSE:The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS:The device used in this study was Octavius 1000 SRS model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870439

    authors: Markovic M,Stathakis S,Mavroidis P,Jurkovic IA,Papanikolaou N

    更新日期:2014-05-01 00:00:00

  • A method for physically based radiotherapy optimization with intelligent tissue weight determination.

    abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1428756

    authors: Jones L,Hoban P

    更新日期:2002-01-01 00:00:00

  • SU-E-J-157: Simulation and Design of a Real-Time 6D Head Motion Compensation Platform Based on a Stewart Platform Approach.

    abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734995

    authors: Belcher AH,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • Projection-domain scatter correction for cone beam computed tomography using a residual convolutional neural network.

    abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13583

    authors: Nomura Y,Xu Q,Shirato H,Shimizu S,Xing L

    更新日期:2019-07-01 00:00:00

  • Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy.

    abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1489044

    authors: Narayanan S,Cho PS,Marks RJ 2nd

    更新日期:2002-07-01 00:00:00

  • Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs.

    abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4950722

    authors: Zhang H,Wang L,Li L,Cai A,Hu G,Yan B

    更新日期:2016-06-01 00:00:00

  • SU-E-J-139: Feasibility of Using EPID for Real-Time Target Localization during Treatment.

    abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734975

    authors: Xu Q,Lin M,Chen X,Tong X,Fan J,Dong Z,Chen L,Ma C

    更新日期:2012-06-01 00:00:00

  • Stereomammography: evaluation of depth perception using a virtual 3D cursor.

    abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599008

    authors: Goodsitt MM,Chan HP,Hadjiiski L

    更新日期:2000-06-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

    abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13900

    authors: Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang G

    更新日期:2020-01-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Correlation between physical measurements and observer evaluations of image quality in digital chest radiography.

    abstract:PURPOSE:The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. METHODS:Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14244

    authors: Yalcin A,Olgar T,Sancak T,Atac GK,Akyar S

    更新日期:2020-09-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.

    abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2199987

    authors: Melhus CS,Rivard MJ

    更新日期:2006-06-01 00:00:00

  • Pharmacokinetic modeling.

    abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597047

    authors: Strand SE,Zanzonico P,Johnson TK

    更新日期:1993-03-01 00:00:00

  • Elements of microdosimetry.

    abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.596616

    authors: Rossi HH,Zaider M

    更新日期:1991-11-01 00:00:00