Abstract:
PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on two groups of patients for whom different patient setup procedures and Sentinel employment conditions were considered. For the first group of 33 patients (FG) no changes to the usual setup procedures were made and a surface extension limited to the treated region was considered. For the second group of 14 patients (SG) the reproducibility of external body surfaces, including body parts not in close proximity to the treatment site, was optimized and a wider surface was captured. In all cases the system accuracy was evaluated comparing registration results from concurrent Sentinel and cone beam CT (CBCT) acquisitions for a total of 192 occasions. External body surfaces, extracted from planning CT studies, were used as reference in both cases, but for SG also surface data captured by Sentinel system at the first treatment were employed. RESULTS:In the 90th percentile of the distributions reporting CBCT and Sentinel registration parameters, absolute differences for FG were less than 6.4 mm and 3.8°. Better performances were observed for SG (≤5.7 mm and 2°). Mean absolute differences between three translation and three rotation parameters of CBCT and Sentinel were: less than 3.5 mm and 2.1° and 3.7 mm and 1.3° in FG for thorax and pelvis, respectively, and less than 2.8 mm and 1° and 2.7 mm and 0.9° for pelvis and thorax, respectively, in SG. No advantage in considering surface data captured by Sentinel as a reference instead of the surface extracted from the planning CT was observed. CONCLUSIONS:The accuracy of Sentinel system in detecting errors is influenced by the extension and reliability of the surface used. When the reproducibility of external body surfaces was optimized differences between CBCT and Sentinel registration parameters resulted less than 5.7 mm and 2° in the 90% of the pelvis and thorax considered cases. No advantage in considering a Sentinel acquisition as reference was observed.
journal_name
Med Physjournal_title
Medical physicsauthors
Pallotta S,Simontacchi G,Marrazzo L,Ceroti M,Paiar F,Biti G,Bucciolini Mdoi
10.1118/1.4769428subject
Has Abstractpub_date
2013-01-01 00:00:00pages
011710issue
1eissn
0094-2405issn
2473-4209journal_volume
40pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477230
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:In this abstract, we discuss a biomechanical head and neck model that will be able to represent patient setup variations as well as physiologic changes and subsequently enable dose calculations on the deformed anatomy. METHODS:We selected Multi Pose MRI as the imaging modality to aid in model development and v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734893
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966704
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3609416
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13952
更新日期:2020-02-01 00:00:00
abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597008
更新日期:1993-07-01 00:00:00
abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598448
更新日期:1998-12-01 00:00:00
abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597209
更新日期:1994-08-01 00:00:00
abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3187231
更新日期:2009-09-01 00:00:00
abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1533749
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS:The device used in this study was Octavius 1000 SRS model...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870439
更新日期:2014-05-01 00:00:00
abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1428756
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734995
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13583
更新日期:2019-07-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4950722
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734975
更新日期:2012-06-01 00:00:00
abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599008
更新日期:2000-06-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13900
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4957389
更新日期:2016-08-01 00:00:00
abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596252
更新日期:1988-03-01 00:00:00
abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4933200
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. METHODS:Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were use...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14244
更新日期:2020-09-01 00:00:00
abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594458
更新日期:1978-11-01 00:00:00
abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2199987
更新日期:2006-06-01 00:00:00
abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597047
更新日期:1993-03-01 00:00:00
abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.596616
更新日期:1991-11-01 00:00:00