Abstract:
:In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to the dose elsewhere in a phantom, were examined. The uncertainties on the measured dose distributions were analyzed with the emphasis on the surface dose measurement. The Monte Carlo method was used to calculate the perturbation correction factors for a photon diode and a NACP plane-parallel ionization chamber at different depths in a water phantom irradiated by 100-300 kV (2.43 mm Al-3.67 mm Cu half-value layer) x-ray beams. The depth-dose curves measured with these two detectors, after correcting for the perturbation effect (up to 15% corrections), agreed with each other to within 1.5%. Comparisons of the doses at the phantom surface and at 2 cm depth in water for photon beams of 100-300 kV tube potential obtained using the "backscatter" method and those using the "in-phantom" measurement have shown that the "in-air" method can be equally applied to this energy range if the depth-dose curve can be measured accurately. To this end, measured depth ionization curves require depth-dependent correction factors.
journal_name
Med Physjournal_title
Medical physicsauthors
Ma CM,Li XA,Seuntjens JPdoi
10.1118/1.598448subject
Has Abstractpub_date
1998-12-01 00:00:00pages
2376-84issue
12eissn
0094-2405issn
2473-4209journal_volume
25pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The quality of tomographic images is directly affected by the system model being used in image reconstruction. An accurate system matrix is desirable for high-resolution image reconstruction, but it often leads to high computation cost. In this work the authors present a maximum a posteriori reconstruction algo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284980
更新日期:2010-02-01 00:00:00
abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594341
更新日期:1977-11-01 00:00:00
abstract:PURPOSE:Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum est...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3676740
更新日期:2012-02-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595995
更新日期:1987-11-01 00:00:00
abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2216876
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13272
更新日期:2019-01-01 00:00:00
abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2794175
更新日期:2007-11-01 00:00:00
abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598389
更新日期:1998-10-01 00:00:00
abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4737025
更新日期:2012-08-01 00:00:00
abstract:PURPOSE:Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measure...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870985
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597867
更新日期:1996-07-01 00:00:00
abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1315317
更新日期:2000-11-01 00:00:00
abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735671
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14425
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:This article presents a new reconstruction method for 3D imaging using a multiple 360 degrees circular orbit cone beam CT system, specifically a way to combine 3D volumes reconstructed with each orbit. The main goal is to improve the noise performance in the combined image while avoiding cone beam artifacts. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3484058
更新日期:2010-10-01 00:00:00
abstract:PURPOSE:Precise segmentation of clinical target volume (CTV) is the key to stomach cancer radiotherapy. We proposed a novel stochastic width - deep neural network (SW-DNN) for better automatically contouring stomach CTV METHODS: SW-DNN was an end-to-end approach, of which the core component was a novel SW mechanism tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14733
更新日期:2021-01-27 00:00:00
abstract::The performance of a diode array (Profiler) was evaluated by comparing its enhanced dynamic wedge (EDW) profiles measured at various depths with point measurements using a 0.03 cm3 ionization chamber on a commercial linear accelerator. The Profiler, which covers a 22.5 cm width, was used to measure larger field widths...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598019
更新日期:1997-07-01 00:00:00
abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14721
更新日期:2021-01-13 00:00:00
abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4957389
更新日期:2016-08-01 00:00:00
abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1373401
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To quantify the inter fraction variation of spatial location of high dose regions of OARs in MR-image based cervix brachytherapy using rigid registration algorithm. METHODS:Retrospective analysis of 27 previously treated patients under EMBRACE multi-centric trial was evaluated. Each patient had two application...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735513
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This study introduces a new hybrid ZTE/Dixon MR-based attenuation correction (MRAC) method including bone density estimation for PET/MRI and quantifies the effects of bone attenuation on metastatic lesion uptake in the pelvis. METHODS:Six patients with pelvic lesions were scanned using fluorodeoxyglucose (18F-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12122
更新日期:2017-03-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4958960
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735979
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461841
更新日期:2002-04-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597412
更新日期:1994-10-01 00:00:00