Abstract:
PURPOSE:This study introduces a new hybrid ZTE/Dixon MR-based attenuation correction (MRAC) method including bone density estimation for PET/MRI and quantifies the effects of bone attenuation on metastatic lesion uptake in the pelvis. METHODS:Six patients with pelvic lesions were scanned using fluorodeoxyglucose (18F-FDG) in an integrated time-of-flight (TOF) PET/MRI system. For PET attenuation correction, MR imaging consisted of two-point Dixon and zero echo-time (ZTE) pulse sequences. A continuous-value fat and water pseudoCT was generated from a two-point Dixon MRI. Bone was segmented from the ZTE images and converted to Hounsfield units (HU) using a continuous two-segment piecewise linear model based on ZTE MRI intensity. The HU values were converted to linear attenuation coefficients (LAC) using a bilinear model. The bone voxels of the Dixon-based pseudoCT were replaced by the ZTE-derived bone to produce the hybrid ZTE/Dixon pseudoCT. The three different AC maps (Dixon, hybrid ZTE/Dixon, CTAC) were used to reconstruct PET images using a TOF-ordered subset expectation maximization algorithm with a point-spread function model. Metastatic lesions were separated into two classes, bone lesions and soft tissue lesions, and analyzed. The MRAC methods were compared using a root-mean-squared error (RMSE), where the registered CTAC was taken as ground truth. RESULTS:The RMSE of the maximum standardized uptake values (SUVmax ) is 11.02% and 7.79% for bone (N = 6) and soft tissue lesions (N = 8), respectively, using Dixon MRAC. The RMSE of SUVmax for these lesions is significantly reduced to 3.28% and 3.94% when using the new hybrid ZTE/Dixon MRAC. Additionally, the RMSE for PET SUVs across the entire pelvis and all patients are 8.76% and 4.18%, for the Dixon and hybrid ZTE/Dixon MRAC methods, respectively. CONCLUSION:A hybrid ZTE/Dixon MRAC method was developed and applied to pelvic regions in an integrated TOF PET/MRI, demonstrating improved MRAC. This new method included bone density estimation, through which PET quantification is improved.
journal_name
Med Physjournal_title
Medical physicsauthors
Leynes AP,Yang J,Shanbhag DD,Kaushik SS,Seo Y,Hope TA,Wiesinger F,Larson PEdoi
10.1002/mp.12122subject
Has Abstractpub_date
2017-03-01 00:00:00pages
902-913issue
3eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597768
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4962483
更新日期:2016-10-01 00:00:00
abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2825622
更新日期:2008-02-01 00:00:00
abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14208
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735747
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734680
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594312
更新日期:1977-09-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract::IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477415
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13163
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829513
更新日期:2013-12-01 00:00:00
abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596741
更新日期:1991-07-01 00:00:00
abstract::The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1494830
更新日期:2002-08-01 00:00:00
abstract::We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596512
更新日期:1990-05-01 00:00:00
abstract::In order to use negative pions for the treatment of large deep-seated tumors in radiotherapy, it is necessary to produce depth-dose distributions tailored to specific shapes. We present here a method of beam shaping which utilizes a fluid-filled piston having a programmable, computer-controlled, time-dependent thickne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594313
更新日期:1977-09-01 00:00:00
abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594755
更新日期:1980-09-01 00:00:00
abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12425
更新日期:2017-09-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13276
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-panel imagers - such as reducing the undesirable effects of electronic...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13128
更新日期:2018-10-01 00:00:00
abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935141
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921046
更新日期:2015-06-01 00:00:00
abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2937652
更新日期:2008-07-01 00:00:00
abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598325
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13887
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:The purpose of this study is to estimate the effect of edema, developed during implant procedure, on tumor cell surviving fraction(SF) and tumor control probability(TCP) in the patients of prostate cancer who underwent 131 Cs permanent seed implants. METHODS:The impact of edema on SF and TCP, was calculated us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735061
更新日期:2012-06-01 00:00:00
abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1350437
更新日期:2001-03-01 00:00:00
abstract::Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598615
更新日期:1999-07-01 00:00:00