Automation of routine elements for spot-scanning proton patient-specific quality assurance.

Abstract:

PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency. METHODS:We used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D-3D γ-index analysis comparing measurements in the plane of a two-dimensional detector array with TPS predictions in a water phantom for each acquired measurement. RESULTS:Device connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating γ-index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan. CONCLUSIONS:The automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.

journal_name

Med Phys

journal_title

Medical physics

authors

Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

doi

10.1002/mp.13246

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

5-14

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016).

    abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1002/mp.12019

    authors: Brivio D,Sajo E,Zygmanski P

    更新日期:2017-03-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • Inter- and intra-software reproducibility of computed tomography lung density measurements.

    abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14130

    authors: Kirby M,Hatt C,Obuchowski N,Humphries SM,Sieren J,Lynch DA,Fain SB,QIBA Lung Density Committee.

    更新日期:2020-07-01 00:00:00

  • Characterization of XR-RV3 GafChromic(®) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors.

    abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922132

    authors: Farah J,Trianni A,Ciraj-Bjelac O,Clairand I,De Angelis C,Delle Canne S,Hadid L,Huet C,Jarvinen H,Negri A,Novák L,Pinto M,Siiskonen T,Waryn MJ,Knežević Ž

    更新日期:2015-07-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

    abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767763

    authors: Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele P

    更新日期:2012-12-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597228

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-12-01 00:00:00

  • Oblique incidence for broad monoenergetic proton beams.

    abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3495969

    authors: Jette D,Yuan J,Chen W

    更新日期:2010-11-01 00:00:00

  • Effective point of measurement of thimble ion chambers in megavoltage photon beams.

    abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3266750

    authors: Tessier F,Kawrakow I

    更新日期:2010-01-01 00:00:00

  • Statistical analysis of dose-volume and dose-wall histograms for rectal toxicity following 3D-CRT in prostate cancer.

    abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1951427

    authors: García-Vicente F,Zapatero A,Floriano A,Cruz-Conde A,Perez L,Marín A,Mínguez C,Torres JJ

    更新日期:2005-08-01 00:00:00

  • Clinical apparatus for the reduction of dose area product for patients undergoing x-ray catheterization.

    abstract:PURPOSE:The authors describe a design for prepatient region of interest attenuators (ROIAs) to reduce dose area product (DAP) for clinical use. The authors describe a model to predict DAP values from x-ray technique parameters recorded during a clinical procedure for image sequences obtained in the presence or absence ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903898

    authors: Robert N,Watt KN,Rochette S,Desponds L,Vaillant R,Rowlands JA

    更新日期:2015-01-01 00:00:00

  • An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

    abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517613

    authors: Arnold ML,McNeill FE,Stronach IM,Pejovic-Milic A,Chettle DR,Waker A

    更新日期:2002-11-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • A Laplace transform pair model for spectral reconstruction.

    abstract::A four-parameter Laplace transform pair model, which accurately reconstructs an experimental bremsstrahlung spectrum from attenuation data, is presented. Computed spectral values with both aluminum and copper attenuators generally agree with experimental 70-kVp data to better than 2%. Reconstructed spectra at other kV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595193

    authors: Archer BR,Wagner LK

    更新日期:1982-11-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Comparison of the cobalt-60 photon beam dose distributions corrected by three shift-factors for oblique incidence.

    abstract::A new factor for shifting isodoes curves for oblique Co-60 photon beams has been deduced. Like the two other known factors, this shift factor depends on the source-to-surface distance (SSD), the depth dose (D) and the derivative of D with depth. A comparison of corrected dose distributions has been made by using the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594688

    authors: Iwasaki A,Ishito T

    更新日期:1980-05-01 00:00:00

  • Calculation of lung mean dose and quantification of error for 90 Y-microsphere radioembolization using 99m Tc-MAA SPECT/CT and diagnostic chest CT.

    abstract:PURPOSE:Current treatment planning for 90 Y radioembolization estimates lung mean dose (LMD) by measuring the lung shunt fraction (LSF) from 99m Tc-macroaggregated albumin (MAA) planar imaging and assuming a 1-kg lung mass. This methodology, however, overestimates LSF and LMD and could therefore unnecessarily limit the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13575

    authors: Lopez B,Mahvash A,Lam MGEH,Kappadath SC

    更新日期:2019-09-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • Poster - Thurs Eve-38: CT Imaging in high dose rate brachytherapy for treatment of cervical cancer: Estimation of dose to bowel.

    abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965957

    authors: Lekx-Toniolo KS,Hunter R,Patel M,Voruganti S,Johanson C,Dhamanaskar K,Farrell T

    更新日期:2008-07-01 00:00:00

  • Quantitative assessment of bone mineral by photon scattering: accuracy and precision considerations.

    abstract::A method to determine the bone mineral density of the calcaneum has been reported earlier by our laboratory. In this method, the calcaneum is irradiated by a 60-keV photon beam from 241Am source and both the coherent and Compton scattered photons are detected by a high-purity Ge detector. The bone mineral density is d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595669

    authors: Shukla SS,Karellas A,Leichter I,Craven JD,Greenfield MA

    更新日期:1985-07-01 00:00:00

  • Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy.

    abstract:PURPOSE:The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. METHODS:Balanced data according to the one-factor random effect model were assumed. RESULTS:Analysis-of-variance (anova)-based computation was ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4961397

    authors: Matsuo Y,Nakamura M,Mizowaki T,Hiraoka M

    更新日期:2016-09-01 00:00:00

  • SU-F-BRCD-09: Total Variation (TV) Based Fast Convergent Iterative CBCT Reconstruction with GPU Acceleration.

    abstract:PURPOSE:To improve image quality and reduce imaging dose in CBCT for radiation therapy applications and to realize near real-time image reconstruction based on use of a fast convergence iterative algorithm and acceleration by multi-GPUs. METHODS:An iterative image reconstruction that sought to minimize a weighted leas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735747

    authors: Xu Q,Yang D,Tan J,Anastasio M

    更新日期:2012-06-01 00:00:00

  • Large field of view distortion assessment in a low-field MR-linac.

    abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13467

    authors: Nejad-Davarani SP,Kim JP,Du D,Glide-Hurst C

    更新日期:2019-05-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00

  • Scatter transmission through an ideal grid.

    abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594877

    authors: Siddon RL

    更新日期:1981-11-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00