Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

Abstract:

:The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction free measure of output factors but it can be challenging to obtain high quality dosimetric results using this film. We propose minimizing errors in the clinical determination of small field output factors by employing diode measurements with Monte-Carlo generated corrections for small fields ≤10 mm diameter and using small volume ion chambers for apertures >10 mm diameter with independent validation using radiochromic film. We performed patient specific quality assurance (QA) measurements for 9 patients using GAFCHROMIC® film and an A16 small volume ion chamber in a head-shaped phantom, employing this hybrid dual detector method for relative output factor measurements within the Multiplan treatment planning system. Our results suggest that consistent output factors can be determined using this method with experimental verification using GAFCHROMIC® film dosimetry. For the patient specific QA using film, we achieve good dosimetric agreement (<2σ) of the measured and calculated average dose for pixels within the 80% isodose line. For patient specific QA using the micro-ion chamber, we get good agreement (<3%) for cone sizes greater than 5 mm. The differences observed for the 5 mm cone plans are consistent with a 1 mm radial setup uncertainty for patient positioning using the Cyberknife system.

journal_name

Med Phys

journal_title

Medical physics

authors

Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

doi

10.1118/1.4740095

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4621

issue

7Part2

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3483784

    authors: Kesner AL,Kuntner C

    更新日期:2010-10-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • Thermal limits on MV x-ray production by bremsstrahlung targets in the context of novel linear accelerators.

    abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12615

    authors: Wang J,Trovati S,Borchard PM,Loo BW Jr,Maxim PG,Fahrig R

    更新日期:2017-12-01 00:00:00

  • SU-E-T-576: Investigation of Combining Modulated Electron Beams with Intensity Modulated Photons for Radiation Therapy of Breast Cases.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735665

    authors: Eldib A,Li J,Jin L,Ma C

    更新日期:2012-06-01 00:00:00

  • Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system.

    abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3656025

    authors: Diffenderfer ES,Ainsley CG,Kirk ML,McDonough JE,Maughan RL

    更新日期:2011-11-01 00:00:00

  • A multipinhole small animal SPECT system with submillimeter spatial resolution.

    abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2190332

    authors: Funk T,Després P,Barber WC,Shah KS,Hasegawa BH

    更新日期:2006-05-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling.

    abstract:PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13868

    authors: Seasons GM,Mazerolle EL,Sankar T,Martino D,Kiss ZHT,Pichardo S,Pike GB

    更新日期:2019-12-01 00:00:00

  • TU-E-BRB-01: Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiation Therapy.

    abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735950

    authors: Magome T,Arimura H,Shioyama Y,Mizoguchi A,Tokunaga C,Nakamura K,Honda H,Ohki M,Toyofuku F,Hirata H

    更新日期:2012-06-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms.

    abstract:PURPOSE:Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little inform...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12406

    authors: Ger RB,Yang J,Ding Y,Jacobsen MC,Fuller CD,Howell RM,Li H,Jason Stafford R,Zhou S,Court LE

    更新日期:2017-10-01 00:00:00

  • Transrectal ultrasound based prostate volume determination: is the frustum algorithm more accurate than planimetry?

    abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4789920

    authors: Liu D,Usmani N,Sloboda RS

    更新日期:2013-03-01 00:00:00

  • Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

    abstract::The physical factors that govern 2D and 3D imaging performance may be understood from quantitative analysis of the spatial-frequency-dependent signal and noise transfer characteristics [e.g., modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002414

    authors: Tward DJ,Siewerdsen JH

    更新日期:2008-12-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Potential of in vivo MRI-based nonlinear finite-element analysis for the assessment of trabecular bone post-yield properties.

    abstract:PURPOSE:Bone strength is the key factor impacting fracture risk. Assessment of bone strength from high-resolution (HR) images have largely relied on linear micro-finite element analysis (μFEA) even though failure always occurs beyond the yield point, which is outside the linear regime. Nonlinear μFEA may therefore be m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4802085

    authors: Zhang N,Magland JF,Rajapakse CS,Bhagat YA,Wehrli FW

    更新日期:2013-05-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00

  • The Cole relaxation frequency as a parameter to identify cancer in breast tissue.

    abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4725172

    authors: Gregory WD,Marx JJ,Gregory CW,Mikkelson WM,Tjoe JA,Shell J

    更新日期:2012-07-01 00:00:00

  • A limited-angle intrafraction verification (LIVE) system for radiation therapy.

    abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861820

    authors: Ren L,Zhang Y,Yin FF

    更新日期:2014-02-01 00:00:00

  • The x-ray light valve: a potentially low-cost, digital radiographic imaging system-concept and implementation considerations.

    abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2837288

    authors: Webster CA,Koprinarov I,Germann S,Rowlands JA

    更新日期:2008-03-01 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00

  • Use of 48Ca as a stable isotope tracer analyzed by proton activation.

    abstract::The use of the stable isotope 48Ca as a tracer in biological systems has been studied. Determination of 48Ca concentrations in samples was accomplished by proton activation via the (p,n) reaction with subsequent measurement of gamma-ray spectra from 44-h 48Sc and 4-h 44Sc. With protons of about 5.5 MeV and a Ge(Li) ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594303

    authors: Edwards FM,Kraushaar JJ,Ristinen RA,Rudolph H

    更新日期:1977-01-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation.

    abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513991

    authors: Mah D,Steckner M,Palacio E,Mitra R,Richardson T,Hanks GE

    更新日期:2002-11-01 00:00:00

  • In vivo functional chronic imaging of a small animal model using optical-resolution photoacoustic microscopy.

    abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3137572

    authors: Hu S,Maslov K,Wang LV

    更新日期:2009-06-01 00:00:00

  • SU-E-J-106: Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer.

    abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734942

    authors: Pirozzi S,Horvat M,Piper J,Nelson A

    更新日期:2012-06-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    abstract::Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3125137

    authors: Jost G,Mensing T,Golfier S,Lawaczeck R,Pietsch H,Hütter J,Cibik L,Gerlach M,Krumrey M,Fratzscher D,Arkadiev V,Wedell R,Haschke M,Langhoff N,Wust P,Lüdemann L

    更新日期:2009-06-01 00:00:00

  • Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578602

    authors: Su Z,Zhang L,Ramakrishnan V,Hagan M,Anscher M

    更新日期:2011-05-01 00:00:00

  • Technical Note: Gray tracking in medical color displays-A report of Task Group 196.

    abstract:PURPOSE:The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. METHODS:The authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953186

    authors: Badano A,Wang J,Boynton P,Le Callet P,Cheng WC,Deroo D,Flynn MJ,Matsui T,Penczek J,Revie C,Samei E,Steven PM,Swiderski S,Van Hoey G,Yamaguchi M,Hasegawa M,Nagy BV

    更新日期:2016-07-01 00:00:00