Abstract:
PURPOSE:The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. METHODS:The authors present data regarding the capability of color measurement instruments with respect to their abilities to measure a target white point corresponding to the CIE Standard Illuminant D65 at different luminance values within the grayscale palette of a medical display. The authors then discuss evidence of significant differences in performance among color measurement instruments currently available for medical physicists to perform calibrations and image quality checks for the consistent representation of color in medical displays. In addition, the authors introduce two metrics for quantifying grayscale chromaticity consistency of gray tracking. RESULTS:The authors' findings show that there is an order of magnitude difference in the accuracy of field and reference instruments. The gray tracking metrics quantify how close the grayscale chromaticity is to the chromaticity of the full white point (equal amounts of red, green, and blue at maximum level) or to consecutive levels (equal values for red, green, and blue), with a lower value representing an improved grayscale tracking performance. An illustrative example of how to calculate and report the gray tracking performance according to the Task Group definitions is provided. CONCLUSIONS:The authors' proposed methodology for characterizing the grayscale degradation in chromaticity for color monitors that can be used to establish standards and procedures aiding in the quality control testing of color displays and color measurement instrumentation.
journal_name
Med Physjournal_title
Medical physicsauthors
Badano A,Wang J,Boynton P,Le Callet P,Cheng WC,Deroo D,Flynn MJ,Matsui T,Penczek J,Revie C,Samei E,Steven PM,Swiderski S,Van Hoey G,Yamaguchi M,Hasegawa M,Nagy BVdoi
10.1118/1.4953186subject
Has Abstractpub_date
2016-07-01 00:00:00pages
4017issue
7eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1823571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:To develop an automated treatment planning strategy for external beam intensity-modulated radiation therapy (IMRT), including a deep learning-based three-dimensional (3D) dose prediction and a dose distribution-based plan generation algorithm. METHODS AND MATERIALS:A residual neural network-based deep learning...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13271
更新日期:2019-01-01 00:00:00
abstract::When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596740
更新日期:1991-11-01 00:00:00
abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508110
更新日期:2002-10-01 00:00:00
abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734975
更新日期:2012-06-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00
abstract:PURPOSE:In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. St...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881515
更新日期:2014-07-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13579
更新日期:2019-07-01 00:00:00
abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1315317
更新日期:2000-11-01 00:00:00
abstract::The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1494830
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.4794925
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:Arterial distensibility is a marker that can measure vessel wall functional and structural changes resulting from atherosclerosis with applications including estimation of mechanical properties of the wall. We sought to assess the feasibility of using magnetic resonance imaging (MRI) to include wall distensibil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754302
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812431
更新日期:2013-08-01 00:00:00
abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598510
更新日期:1999-02-01 00:00:00
abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597307
更新日期:1994-03-01 00:00:00
abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596296
更新日期:1988-07-01 00:00:00
abstract::This investigation contains the results of exposure measurements on two types of clinical I-125 seeds: a model 6702 no-marker seed, and a model 6711 silver wire seed. Measurements were made locally with a parallel-plate mammography chamber, traceable to the National Bureau of Standards (NBS) calibration. The same seed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595784
更新日期:1985-03-01 00:00:00
abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1449876
更新日期:2002-03-01 00:00:00
abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2896070
更新日期:2008-05-01 00:00:00
abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598753
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4747261
更新日期:2012-10-01 00:00:00
abstract::A method to correct for geometric image distortion in the x-ray imaging chain, so-called dewarping, has been developed. A global two-dimensional polynomial model of which the degree is optimized is used. The performance of the method has been tested in a number of experiments using images of a plate with a 1 cm spaced...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598101
更新日期:1997-12-01 00:00:00
abstract:PURPOSE:Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstructio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12692
更新日期:2018-02-01 00:00:00
abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3095777
更新日期:2009-04-01 00:00:00
abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1809778
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242304
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:This study aims to investigate the prompt secondary gamma spectrum and thedepth-dose distributions of incident 40 MeV protons onto various phantom materials.The goal is to find a relationship between the secondary prompt gamma emissions andthe range of the incident particles. METHODS:An application was constru...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735388
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4830427
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916802
更新日期:2015-05-01 00:00:00