Abstract:
PURPOSE:Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstruction from few-views and limited-angle data. METHOD:A new optimization algorithm based on the optimization transfer principle is proposed. The proposed algorithm uses TVM as the regularization term of the cost function that ensures the quality of the CT image reconstructed from few-views and limited-angle data. Additionally, half of the square of the difference between the original projection and the forward projection is used as the fidelity term. We then proved that the regularization term, i.e., 2-norm TV, is a convex function. Based on the convexity of the regularization and fidelity terms, a separable quadratic surrogate (SQS) function was proposed to substitute the regularization and fidelity terms. The solution of the cost function can be obtained by minimizing the SQS function and building the next SQS function at the minimum point. RESULTS:Both numerical simulations and simulations using real experimental data showed that the proposed algorithm reconstruct high-quality CT image from few-views and limited-angle data. The differences between the image reconstructed by the proposed algorithm and the images reconstructed by the previous algorithms are very small. However, the proposed algorithm required less than 1/10 time of the computational time of the previous algorithms. The image quality is not assessed in a rigorous way. CONCLUSION:The proposed algorithm can greatly accelerate the accurate CT reconstruction from few-views and limited-angle data relative to previous algorithms.
journal_name
Med Physjournal_title
Medical physicsauthors
Hou X,Teng Y,Kang Y,Qi Sdoi
10.1002/mp.12692subject
Has Abstractpub_date
2018-02-01 00:00:00pages
535-548issue
2eissn
0094-2405issn
2473-4209journal_volume
45pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736218
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892606
更新日期:2014-09-01 00:00:00
abstract::Imaging of radiation dose distribution in gel phantoms by magnetic resonance techniques has previously been reported. In this paper a method of producing gels in which the distributions of radiation dose can also be visualized as a color change is reported. The color developed depends qualitatively and quantitatively ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596676
更新日期:1991-03-01 00:00:00
abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767763
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:We report on the development of the open-source cross-platform radiation treatment planning toolkit matRad and its comparison against validated treatment planning systems. The toolkit enables three-dimensional intensity-modulated radiation therapy treatment planning for photons, scanned protons and scanned carb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12251
更新日期:2017-06-01 00:00:00
abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597041
更新日期:1993-03-01 00:00:00
abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594341
更新日期:1977-11-01 00:00:00
abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598916
更新日期:2000-03-01 00:00:00
abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12778
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829513
更新日期:2013-12-01 00:00:00
abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3062944
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734773
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14742
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760774
更新日期:2012-11-01 00:00:00
abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594910
更新日期:1981-01-01 00:00:00
abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773045
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To automatically and efficiently segment the lesion area of the colonoscopy polyp image, a polyp segmentation method has been presented. METHODS:An ensemble model of pretrained convolutional neural networks was proposed, using Unet-VGG, SegNet-VGG, and PSPNet. Firstly, the Unet-VGG is obtained by the first 10 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13865
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Traditionally, unidirectional leaf-sweeping schemes have been employed to deliver IMRT plans using the dynamic multileaf collimator (DMLC) technique. The goal of this research is to investigate the potential impact of relaxing the leaf-motion restrictions in DMLC IMRT on the beam-modulation quality and the deli...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13158
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4816656
更新日期:2013-09-01 00:00:00
abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597973
更新日期:1997-10-01 00:00:00
abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597122
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1002/mp.13518
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:Intraoperative electron radiation therapy (IOERT) involves the delivery of a high radiation dose during tumor resection in a shorter time than other radiation techniques, thus improving local control of tumors. However, a linear accelerator device is needed to produce the beam safely. Mobile linear accelerators...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12482
更新日期:2017-10-01 00:00:00
abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598293
更新日期:1998-06-01 00:00:00
abstract::We present a technique for semiautomated segmentation of human prostates using suprapubic ultrasound (US) images. In this approach, a speckle reducing anisotropic diffusion (SRAD) is applied to enhance the images and the instantaneous coefficient of variation (ICOV) is utilized for edge detection. Segmentation is acco...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809791
更新日期:2004-12-01 00:00:00
abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2919724
更新日期:2008-06-01 00:00:00
abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4805102
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measur...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12585
更新日期:2017-12-01 00:00:00
abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386424
更新日期:2001-09-01 00:00:00
abstract:PURPOSE:In our institute, the MatriXX has been used for IMRT, VMAT and dynamic arc QA. However, the small fields (<3cm) shaped by HDMLC for SRS dynamic arc (DA) present QA measurement issues when using the MatriXX due to its limited resolution (7.6 mm). A recently available portal dosimetry (PD) software tool in Eclips...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735167
更新日期:2012-06-01 00:00:00