Changes realized from extended bit-depth and metal artifact reduction in CT.

Abstract:

PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. METHODS:Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc∕Dosxyz (400,000,0000 histories, 6X, 10 × 10 cm(2) beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%∕2 mm. RESULTS:For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 ± 56.6 and 13,588.5 ± 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was ∼6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit (∼10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower (∼17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. CONCLUSIONS:These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

journal_name

Med Phys

journal_title

Medical physics

authors

Glide-Hurst C,Chen D,Zhong H,Chetty IJ

doi

10.1118/1.4805102

subject

Has Abstract

pub_date

2013-06-01 00:00:00

pages

061711

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • Optical image processing with liquid-crystal display for image intensifier/television systems.

    abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596199

    authors: Lam KL,Chan HP,Doi K

    更新日期:1988-11-01 00:00:00

  • A contrast-detail analysis of diagnostic ultrasound imaging.

    abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595218

    authors: Smith SW,Lopez H

    更新日期:1982-01-01 00:00:00

  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

    abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2103447

    authors: Vences L,Wulf J,Vordermark D,Sauer O,Berlinger K,Roth M

    更新日期:2005-11-01 00:00:00

  • A voxel-based multiscale model to simulate the radiation response of hypoxic tumors.

    abstract:PURPOSE:In radiotherapy, it is important to predict the response of tumors to irradiation prior to the treatment. This is especially important for hypoxic tumors, which are known to be highly radioresistant. Mathematical modeling based on the dose distribution, biological parameters, and medical images may help to impr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903298

    authors: Espinoza I,Peschke P,Karger CP

    更新日期:2015-01-01 00:00:00

  • Effect of the first day correction on systematic setup error reduction.

    abstract::Treatment simulation is usually performed with a conventional simulator using kV X-rays or with a computed tomography (CT) simulator before the treatment course begins. The purpose is to verify patient setup under the same conditions as for treatment planning. Systematic (preparation) setup errors can be introduced by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2727299

    authors: Wu Q,Lockman D,Wong J,Yan D

    更新日期:2007-05-01 00:00:00

  • Poster - Thurs Eve-38: CT Imaging in high dose rate brachytherapy for treatment of cervical cancer: Estimation of dose to bowel.

    abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965957

    authors: Lekx-Toniolo KS,Hunter R,Patel M,Voruganti S,Johanson C,Dhamanaskar K,Farrell T

    更新日期:2008-07-01 00:00:00

  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation.

    abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2776255

    authors: Lu HM,Brett R,Engelsman M,Slopsema R,Kooy H,Flanz J

    更新日期:2007-10-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

    abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1852791

    authors: Childress NL,Salehpour M,Dong L,Bloch C,White RA,Rosen II

    更新日期:2005-02-01 00:00:00

  • A novel respiratory tracking system for smart-gated PET acquisition.

    abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523100

    authors: Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JL

    更新日期:2011-01-01 00:00:00

  • A separable quadratic surrogate total variation minimization algorithm for accelerating accurate CT reconstruction from few-views and limited-angle data.

    abstract:PURPOSE:Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstructio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12692

    authors: Hou X,Teng Y,Kang Y,Qi S

    更新日期:2018-02-01 00:00:00

  • SU-E-J-46: Use of Brainlab-ExacTrac IGRT with Dot-Decimal Electron Compensator(BolusECT) for Accurate Patient Positioning.

    abstract:PURPOSE:To Validate Brainlab-ExacTrac IGRT with Dot-Decimal electron compensator(BolusECT) for accurate patient positioning. METHODS:Dot-Decimal electron compensators(BolusECT) are used to achieve conformal dose distributions and greater sparing to normal structures for cases with varying patient contours and treated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734881

    authors: Prabhu A,Saini D,Patadiya B,Shankar R,Garthwaite T

    更新日期:2012-06-01 00:00:00

  • Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time.

    abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914863

    authors: Wild E,Bangert M,Nill S,Oelfke U

    更新日期:2015-05-01 00:00:00

  • Computational analysis and dosimetric evaluation of a commercial irregular-fields computer program.

    abstract::The proper evaluation of the accuracy of a new computer program for radiation-therapy dosimetry requires consideration of both the mathematical algorithm used in the program and the performance required in clinical applications. As an example, our evaluation of the irregular-fields dosimetry program currently marketed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594344

    authors: Hallberg JR,Ibbott GS,Carson PL,Hendee WR

    更新日期:1977-11-01 00:00:00

  • Implementing RapidArc into clinical routine: a comprehensive program from machine QA to TPS validation and patient QA.

    abstract:PURPOSE:With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3622672

    authors: Van Esch A,Huyskens DP,Behrens CF,Samsoe E,Sjolin M,Bjelkengren U,Sjostrom D,Clermont C,Hambach L,Sergent F

    更新日期:2011-09-01 00:00:00

  • Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system.

    abstract::A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computeriz...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2955751

    authors: Vinci JP,Hogstrom KR,Neck DW

    更新日期:2008-08-01 00:00:00

  • Soft-tissue detectability in cone-beam CT: evaluation by 2AFC tests in relation to physical performance metrics.

    abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2790586

    authors: Tward DJ,Siewerdsen JH,Daly MJ,Richard S,Moseley DJ,Jaffray DA,Paul NS

    更新日期:2007-11-01 00:00:00

  • Mammogram synthesis using a three-dimensional simulation. III. Modeling and evaluation of the breast ductal network.

    abstract::A method is proposed for realistic simulation of the breast ductal network as part of a computer three-dimensional (3-D) breast phantom. The ductal network is simulated using tree models. Synthetic trees are generated based upon a description of ductal branching by ramification matrices (R matrices), whose elements re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1586453

    authors: Bakic PR,Albert M,Brzakovic D,Maidment AD

    更新日期:2003-07-01 00:00:00

  • High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.

    abstract:PURPOSE:Patient-specific QA of highly conformal radiotherapy treatments are usually conducted using 2D or 3D dosimetry of the incident dose distribution in a water-equivalent phantom. However, dosimeters typically used for this task usually lack in either spatial resolution or dose accuracy. The purpose of this work is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736526

    authors: Goulet M,Archambault L,Beaulieu L,Gingras L

    更新日期:2012-08-01 00:00:00

  • Radionuclide photon dose kernels for internal emitter dosimetry.

    abstract::Photon point dose kernels and absorbed fractions were generated in water for the full photon emission spectrum of each radionuclide of interest in nuclear medicine, by simulating the transport of particles using Monte Carlo. The kernels were then fitted to a mathematical expression. Absorbed fractions for point source...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597670

    authors: Furhang EE,Sgouros G,Chui CS

    更新日期:1996-05-01 00:00:00

  • Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.

    abstract:PURPOSE:Radioembolization with yttrium-90 microspheres may be optimized with patient-specific pretherapy treatment planning. Dose verification and validation of treatment planning methods require quantitative imaging of the post-therapy distribution of yttrium-90 (Y-90). Methods for quantitative imaging of Y-90 using b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962472

    authors: Yue J,Mauxion T,Reyes DK,Lodge MA,Hobbs RF,Rong X,Dong Y,Herman JM,Wahl RL,Geschwind JH,Frey EC

    更新日期:2016-10-01 00:00:00

  • Analytic microdosimetry for radioimmunotherapeutic alpha emitters.

    abstract::Analytic microdosimetry using Fourier transform techniques has been applied to internal alpha emitters. These techniques need revision and simplification for use with short-lived radionuclides such as those which may be useful for radioimmunotherapy. Analytic methods may have advantages over Monte Carlo methods in som...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596770

    authors: Stinchcomb TG,Roeske JC

    更新日期:1992-11-01 00:00:00

  • Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes.

    abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14729

    authors: Domínguez-Jiménez DY,Alva-Sánchez H

    更新日期:2021-01-21 00:00:00

  • Investigation of spectral performance for single-scan contrast-enhanced breast CT using photon-counting technology: A phantom study.

    abstract:PURPOSE:Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (pcBCT) and to assess the spectral performance of a pcBCT scanner by eva...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14133

    authors: Ruth V,Kolditz D,Steiding C,Kalender WA

    更新日期:2020-07-01 00:00:00

  • Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID.

    abstract:PURPOSE:The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. METHODS:The APS has an active area of 5.4 × 5.4 cm and maximum full frame read-out rate of 20 frame s(-1),...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651632

    authors: Osmond JP,Zin HM,Harris EJ,Lupica G,Allinson NM,Evans PM

    更新日期:2011-11-01 00:00:00

  • A water phantom controller for automated acquisition of linac beam parameters.

    abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596414

    authors: Schmid MG,Morris RL

    更新日期:1989-01-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

    abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/mp.12634

    authors: Yamamoto T,Kabus S

    更新日期:2018-01-01 00:00:00