Investigation of spectral performance for single-scan contrast-enhanced breast CT using photon-counting technology: A phantom study.

Abstract:

PURPOSE:Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (pcBCT) and to assess the spectral performance of a pcBCT scanner by evaluating iodine maps and virtual non-contrast (VNC) images. METHODS:We optimized the settings of a pcBCT to maximize the signal-to-noise ratio between iodinated contrast agent and breast tissue. Therefore, an electronic energy threshold dividing the x-ray spectrum used into two energy bins was swept from 23.17 keV to 50.65 keV. Validation measurements were performed by placing syringes with contrast agent (2.5 mg/ml to 40 mg/ml) in phantoms with 7.5 cm and 12 cm in diameter. Images were acquired at different tube currents and reconstructed with 300 μm isotropic voxel size. Iodine maps and VNC images were generated using image-based material decomposition. Iodine concentrations and CT values were measured for each syringe and compared to the known concentrations and reference CT values. RESULTS:Maximal signal-to-noise ratios were found at a threshold position of 32.59 keV. Accurate iodine quantification (average root mean square error of 0.56 mg/ml) was possible down to a concentration of 2.5 mg/ml for all tube currents investigated. The enhancement has been sufficiently removed in the VNC images, so they can be interpreted as unenhanced CT images. Only minor changes of CT values compared to a conventional CT scan were observed. Noise was increased by the decomposition by a factor of 2.62 and 4.87 (7.5 cm and 12 cm phantoms) but did not compromise the accuracy of the iodine quantification. CONCLUSIONS:Accurate iodine quantification and generation of VNC images can be achieved using contrast-enhanced pcBCT from a single CT scan in the absence of temporal or spatial misalignment. Using iodine maps and VNC images, pcBCT has the potential to reduce dose, shorten examination and reading time, and to increase cancer detection rates.

journal_name

Med Phys

journal_title

Medical physics

authors

Ruth V,Kolditz D,Steiding C,Kalender WA

doi

10.1002/mp.14133

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

2826-2837

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12476

    authors: Gao S,van 't Klooster R,Kitslaar PH,Coolen BF,van den Berg AM,Smits LP,Shahzad R,Shamonin DP,de Koning PJH,Nederveen AJ,van der Geest RJ

    更新日期:2017-10-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • Dosimetry for 252Cf neutron emitting brachytherapy sources: protocol, measurements, and calculations.

    abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598646

    authors: Rivard MJ

    更新日期:1999-08-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Estimation of a photon energy spectrum for a computed tomography scanner.

    abstract::Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598159

    authors: Ruth C,Joseph PM

    更新日期:1997-05-01 00:00:00

  • High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12066

    authors: Jaccard M,Petersson K,Buchillier T,Germond JF,Durán MT,Vozenin MC,Bourhis J,Bochud FO,Bailat C

    更新日期:2017-02-01 00:00:00

  • Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008428

    authors: Zhao W,Li D,Reznik A,Lui BJ,Hunt DC,Rowlands JA,Ohkawa Y,Tanioka K

    更新日期:2005-09-01 00:00:00

  • Oxygen distribution in tumors: a qualitative analysis and modeling study providing a novel Monte Carlo approach.

    abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892386

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2014-09-01 00:00:00

  • A method to estimate transmission profiles of bow-tie filters using rotating tube measurements.

    abstract:PURPOSE:The purpose of this paper was to present a method of determining the dose profile of the beam bow-tie filter (BTF) without the need for fixing the x ray tube in a position or using special instruments or dosimeters other than the ordinary types of ion chambers used for CT dosimetry (e.g., Farmer chamber). METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13203

    authors: Al-Senan R

    更新日期:2018-11-01 00:00:00

  • The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cerenkov discrimination methods.

    abstract::New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2897966

    authors: Frelin AM,Fontbonne JM,Ban G,Colin J,Labalme M,Batalla A,Vela A,Boher P,Braud M,Leroux T

    更新日期:2008-05-01 00:00:00

  • Changes realized from extended bit-depth and metal artifact reduction in CT.

    abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4805102

    authors: Glide-Hurst C,Chen D,Zhong H,Chetty IJ

    更新日期:2013-06-01 00:00:00

  • Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.

    abstract:PURPOSE:An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). METHODS:The proposed MAR algorithm followed a four-step ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947486

    authors: Côté N,Bedwani S,Carrier JF

    更新日期:2016-05-01 00:00:00

  • Reconstruction of 4-MV bremsstrahlung spectra from measured transmission data.

    abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595356

    authors: Huang PH,Kase KR,Bjärngard BE

    更新日期:1983-11-01 00:00:00

  • Assessing radiation and light field congruence with a video based electronic portal imaging device.

    abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597867

    authors: Luchka K,Chen D,Shalev S,Gluhchev G,Rajapakshe R

    更新日期:1996-07-01 00:00:00

  • Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device.

    abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4933200

    authors: Zarghami N,Jensen MD,Talluri S,Foster PJ,Chambers AF,Dick FA,Wong E

    更新日期:2015-11-01 00:00:00

  • Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

    abstract:PURPOSE:Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single pho...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4845195

    authors: Bowsher J,Yan S,Roper J,Giles W,Yin FF

    更新日期:2014-01-01 00:00:00

  • Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

    abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1774131

    authors: Zhang T,Orton NP,Mackie TR,Paliwal BR

    更新日期:2004-09-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy.

    abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598930

    authors: Zavgorodni SF

    更新日期:2000-04-01 00:00:00

  • SU-E-I-69: Magnetic Resonance Metal Artifact Evaluation with Routine Clinical Cardiac Sequences.

    abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734785

    authors: Joyner D,Rivard A,Craft D,Liu T,Callaway S,James J

    更新日期:2012-06-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • Photon dose calculation incorporating explicit electron transport.

    abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597611

    authors: Yu CX,Mackie TR,Wong JW

    更新日期:1995-07-01 00:00:00

  • ARPM-net: A novel CNN-based adversarial method with Markov random field enhancement for prostate and organs at risk segmentation in pelvic CT images.

    abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14580

    authors: Zhang Z,Zhao T,Gay H,Zhang W,Sun B

    更新日期:2020-11-05 00:00:00

  • Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

    abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1852791

    authors: Childress NL,Salehpour M,Dong L,Bloch C,White RA,Rosen II

    更新日期:2005-02-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00

  • Measurement of the replacement correction factor for parallel-plate chambers in electron fields.

    abstract::When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596740

    authors: Reft CS,Kuchnir FT

    更新日期:1991-11-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • Reconstruction of diagnostic x-ray spectra by numerical analysis of transmission data.

    abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595834

    authors: Huang PH,Chen TS,Kase KR

    更新日期:1986-09-01 00:00:00

  • SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735542

    authors: Sheth N,Chen Y,Yang J

    更新日期:2012-06-01 00:00:00