Estimation of a photon energy spectrum for a computed tomography scanner.

Abstract:

:Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung photons. The second model does not include details regarding the underlying physics, but treats the spectrum as a sum of delta functions. A nonlinear regularization method is used to overcome ill conditioning in the second model. Both models fit the transmission data to an accuracy of 0.30%, which is consistent with the experimental error. A quantitative comparison of the models is made by calculating the average and variance (over the derived energy spectra) of several relevant mass attenuation coefficients. The maximum variation in the average and variance was 1.5% and 3.2%, respectively, indicating that the spectra exhibit similar attenuation and beam hardening properties. The spectra were tested with a simulation that predicts scanner CT numbers for phantom measurements consisting of dilutions of sodium iodide in a water equivalent background. The agreement between simulation and experiment ranged from 1.5% at 220 HU to 4.4% at 1700 HU.

journal_name

Med Phys

journal_title

Medical physics

authors

Ruth C,Joseph PM

doi

10.1118/1.598159

subject

Has Abstract

pub_date

1997-05-01 00:00:00

pages

695-702

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

24

pub_type

杂志文章
  • Comparison of three strategies in management of independent movement of the prostate and pelvic lymph nodes.

    abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3480505

    authors: Xia P,Qi P,Hwang A,Kinsey E,Pouliot J,Roach M 3rd

    更新日期:2010-09-01 00:00:00

  • Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain.

    abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596520

    authors: Grady MS,Howard MA 3rd,Molloy JA,Ritter RC,Quate EG,Gillies GT

    更新日期:1990-05-01 00:00:00

  • Thick phosphor screens for on-line portal imaging.

    abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597209

    authors: Wowk B,Shalev S

    更新日期:1994-08-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • The polarity effect for commercially available plane-parallel ionization chambers.

    abstract::The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-033 thin-window ionization chamber. The primary study was the polarity ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596072

    authors: Gerbi BJ,Khan FM

    更新日期:1987-03-01 00:00:00

  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

    abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477230

    authors: Siebers JV,Lauterbach M,Keall PJ,Mohan R

    更新日期:2002-06-01 00:00:00

  • Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12374

    authors: Eichmann M,Thomann B

    更新日期:2017-09-01 00:00:00

  • Sampling methods for a matrix ionization chamber system.

    abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596829

    authors: van Herk M,Bijhold J,Hoogervorst B,Meertens H

    更新日期:1992-03-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • Experimental verification of EGSnrc Monte Carlo calculated depth doses within a realistic parallel magnetic field in a polystyrene phantom.

    abstract:PURPOSE:Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Car...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12413

    authors: Ghila A,Steciw S,Fallone BG,Rathee S

    更新日期:2017-09-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion.

    abstract::Use of dynamic multileaf collimation (DMLC) for intensity modulated radiation therapy (IMRT) is accelerating. Delivery systems have the ailment of interleaf leakage (IL). This is compounded by the inefficiency of IMRT delivery, estimated to be a factor of 5 for DMLC. With IL on the order of 4%, it is possible to deliv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388216

    authors: Klein EE,Low DA

    更新日期:2001-08-01 00:00:00

  • Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy.

    abstract:PURPOSE:To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. METHODS:The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12721

    authors: Rah JE,Shin D,Manger RP,Kim TH,Oh DH,Kim DY,Kim GY

    更新日期:2018-02-01 00:00:00

  • Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

    abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3537610

    authors: Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rd

    更新日期:2011-02-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

    abstract:PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the par...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12855

    authors: Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

    更新日期:2018-05-01 00:00:00

  • An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

    abstract::An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594418

    authors: Rosen I,Smith A,Lane R,Kelsey C,Lake D,Hogstrom K,Somers J,Helland J,Kittell R,Amols H,Bradbury J,Richman C

    更新日期:1978-03-01 00:00:00

  • Experimental test of theoretical models for time-resolved reflectance.

    abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597739

    authors: Cubeddu R,Pifferi A,Taroni P,Torricelli A,Valentini G

    更新日期:1996-09-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy.

    abstract:PURPOSE:The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). METHODS:A pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788644

    authors: Yue NJ,Haffty BG,Kearney T,Kirstein L,Chen S,Goyal S

    更新日期:2013-02-01 00:00:00

  • Daily check instrument for photon and electron beam quality assurance of medical linacs.

    abstract::An instrument for daily beam checks of medical accelerators is described. Using three silicon diodes, the instrument provides information about calibration, beam symmetry, flatness, and energy variation for both photon and electron beams. Operating characteristics of the instrument and the electronic circuit design pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595756

    authors: Lutz WR,Maddox BJ,Kase KR

    更新日期:1985-07-01 00:00:00

  • The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

    abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2775667

    authors: Murphy MJ,Balter J,Balter S,BenComo JA Jr,Das IJ,Jiang SB,Ma CM,Olivera GH,Rodebaugh RF,Ruchala KJ,Shirato H,Yin FF

    更新日期:2007-10-01 00:00:00

  • Accounting for the fringe magnetic field from the bending magnet in a Monte Carlo accelerator treatment head simulation.

    abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3592640

    authors: O'Shea TP,Foley MJ,Faddegon BA

    更新日期:2011-06-01 00:00:00

  • The enhancement of radiotherapy verification images by an automated edge detection technique.

    abstract::Adaptive histogram equalization techniques are known to be effective for the enhancement of contrast in portal images acquired during radiotherapy treatments. A significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it can be remedied by separating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596807

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1992-05-01 00:00:00

  • A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

    abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12998

    authors: Harris W,Wang C,Yin FF,Cai J,Ren L

    更新日期:2018-07-01 00:00:00

  • Off-axis beam quality change in linear accelerator x-ray beams.

    abstract::The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594677

    authors: Hanson WF,Berkley LW,Peterson M

    更新日期:1980-03-01 00:00:00