Abstract:
PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the full range of clinical field sizes and patient positions. Recently, disassembly of the treatment head of a linear accelerator has been used to refine the simulation of the electron beam, setting tightly measured constraints on source and geometry parameters used in simulation. The simulation did not explicitly include the known deflection of the electron beam by a fringe magnetic field from the bending magnet, which extended into the treatment head. Instead, the secondary scattering foil and monitor chamber were unrealistically laterally offset to account for the beam deflection. This work is focused on accounting for this fringe magnetic field in treatment head simulation. METHODS:The magnetic field below the exit window of a Siemens Oncor linear accelerator was measured with a Tesla-meter from 0 to 12 cm from the exit window and 1-3 cm off-axis. Treatment head simulation was performed with the EGSnrc/BEAMnrc code, modified to incorporate the effect of the magnetic field on charged particle transport. Simulations were used to analyze the sensitivity of dose profiles to various sources of asymmetry in the treatment head. This included the lateral spot offset and beam angle at the exit window, the fringe magnetic field and independent lateral offsets of the secondary scattering foil and electron monitor chamber. Simulation parameters were selected within the limits imposed by measurement uncertainties. Calculated dose distributions were then compared with those measured in water. RESULTS:The magnetic field was a maximum at the exit window, increasing from 0.006 T at 6 MeV to 0.020 T at 21 MeV and dropping to approximately 5% of the maximum at the secondary scattering foil. It was up to three times higher in the bending plane, away from the electron gun, and symmetric within measurement uncertainty in the transverse plane. Simulations showed the magnetic field resulted in an offset of the electron beam of 0.80 cm (mean) at the machine isocenter for the exit window only configuration. The fringe field resulted in a 3.5%-7.6% symmetry and 0.25-0.35 cm offset of the clinical beam R(max) profiles. With the magnetic field included in simulations, a single (realistic) position of the secondary scattering foil and monitor chamber was selected. Measured and simulated dose profiles showed agreement to an average of 2.5%/0.16 cm (maximum: 3%/0.2 cm), which is a better match than previously achieved without incorporating the magnetic field in the simulation. The undulations from the 3 stepped layers of the secondary scattering foil, evident in the measured profiles of the higher energy beams, are now aligned with those in the simulated beam. The simulated fringe magnetic field had negligible effect on the central axis depth dose curves and cross-plane dose profiles. CONCLUSIONS:The fringe magnetic field is a significant contributor to the electron beam in-plane asymmetry. With the magnetic field included explicitly in the simulation, realistic monitor chamber and secondary scattering foil positions have been achieved, and the calculated fluence and dose distributions are more accurate.
journal_name
Med Physjournal_title
Medical physicsauthors
O'Shea TP,Foley MJ,Faddegon BAdoi
10.1118/1.3592640subject
Has Abstractpub_date
2011-06-01 00:00:00pages
3260-9issue
6eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The scattered-photon part of pencil-beam dose kernels for high-energy x-ray beams can be derived experimentally by differentiating the broad-beam scatter-to-primary dose ratio as a function of radius. Formally, this requires a uniform and parallel beam, and the procedure is complicated by the nonideal, actual beam con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597884
更新日期:1996-09-01 00:00:00
abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3560428
更新日期:2011-04-01 00:00:00
abstract::Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination take...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595867
更新日期:1986-09-01 00:00:00
abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2432404
更新日期:2007-02-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3442276
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:This study aims to investigate carotid plaque calcification (CPC) using two-dimensional (2D) and 3D ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences and compare T1, T2*, water concentration, and bone mineral density (BMD) of CPC with those of cortical bone. METHODS:Twelve carotid plaque sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819944
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for bot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3319498
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615059
更新日期:2011-08-01 00:00:00
abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3173815
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3595112
更新日期:2011-07-01 00:00:00
abstract::A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value la...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1608498
更新日期:2003-10-01 00:00:00
abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596648
更新日期:1991-09-01 00:00:00
abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597303
更新日期:1994-03-01 00:00:00
abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594403
更新日期:1978-01-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13391
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4747261
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To simplify the often complex and user-dependent manual region of interest (ROI) selection process for head motion monitoring, an automatic ROI selection method was developed. METHODS:The automatic ROI selection algorithm calculated the displacements and velocities of 3D surface points between a temporally cor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4711805
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract::Computer-aided diagnosis (CAD) has been a major field of research for the past few decades. CAD uses machine learning methods to analyze imaging and/or nonimaging patient data and makes assessment of the patient's condition, which can then be used to assist clinicians in their decision-making process. The recent succe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13764
更新日期:2020-06-01 00:00:00
abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1413519
更新日期:2001-12-01 00:00:00
abstract::Purpose To investigate narrow, elongated magnetically focused proton beams and compare their properties with passively collimated beams using Monte Carlo simulation. METHODS:We performed Geant4 Monte Carlo simulations involving a single quadrapole focusing magnet, thereby creating a flattened beam with an elongated e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735386
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868693
更新日期:2014-04-01 00:00:00
abstract::A calculation is described that enables the rapid assessment of dose rate at various points of interest within the eye (lens, optic nerve, etc.) for the treatment of choroidal melanoma by plaque therapy. 125I seeds are used as the radiation source. The location of the plaque and its associated seeds relative to the ey...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596234
更新日期:1988-05-01 00:00:00
abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1523932
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948687
更新日期:2016-06-01 00:00:00
abstract::This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1634482
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945414
更新日期:2016-05-01 00:00:00
abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1869652
更新日期:2005-04-01 00:00:00