A new pulse sequence for determining T1 and T2 simultaneously.

Abstract:

:Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination takes place in this case pixel by pixel from the measured images. The measuring time corresponds in this case approximately to that of a normal spin-echo sequence with long repetition time and two data acquisitions. The functional dependence of the accuracy of the T1 and T2 determination upon external errors, e.g., angle of rotation errors, is discussed. The tissue contrast behavior of the individual echoes is shown and its dependence on pulse parameters is explained.

journal_name

Med Phys

journal_title

Medical physics

authors

Graumann R,Fischer H,Oppelt A

doi

10.1118/1.595867

subject

Has Abstract

pub_date

1986-09-01 00:00:00

pages

644-7

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

13

pub_type

杂志文章
  • Electromagnetic wave propagation in a fast pulse line ion accelerator.

    abstract:PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13875

    authors: Behbahani RA,Diot Q,Kavanagh B,Serkova NJ,Miften M,Westerly DC

    更新日期:2019-12-01 00:00:00

  • Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.

    abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13272

    authors: Shunhavanich P,Hsieh SS,Pelc NJ

    更新日期:2019-01-01 00:00:00

  • The effect of dose calculation uncertainty on the evaluation of radiotherapy plans.

    abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598916

    authors: Keall PJ,Siebers JV,Jeraj R,Mohan R

    更新日期:2000-03-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

    abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1487861

    authors: Kachelriess M,Sennst DA,Maxlmoser W,Kalender WA

    更新日期:2002-07-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Technical Note: Transconvolution based equalization of positron energy effects for the use of 68 Ge/68 Ga phantoms in determining 18 F PET recovery.

    abstract:PURPOSE:Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS:RCs were obtained from PET/CT measurements of seve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12330

    authors: Prenosil GA,Hentschel M,Fürstner M,Krause T,Weitzel T,Klaeser B

    更新日期:2017-07-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • Motion tracking of low-activity fiducial markers using adaptive region of interest with list-mode positron emission tomography.

    abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14206

    authors: Chamberland MJP,deKemp RA,Xu T

    更新日期:2020-08-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • The effects of motion on quantitative vessel measurements.

    abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595651

    authors: Parker DL,Clayton PD,Gustafson DE

    更新日期:1985-11-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.

    abstract:PURPOSE:to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS:A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondenc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736204

    authors: Poels K,Depuydt T,Verellen D,De Ridder M

    更新日期:2012-06-01 00:00:00

  • Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation.

    abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597672

    authors: Spirou SV,Chui CS

    更新日期:1996-01-01 00:00:00

  • Poster - Thurs Eve-10: The accuracy of MU calculations for enhanced dynamic wedge with the Varian's anisotropic analytical algorithm.

    abstract::The Anisotropic Analytical Algorithm (AAA) of the Varian Eclipse treatment planning system calculates absolute dose for a variety of beam settings including those with an enhanced dynamic wedge (EDW). This algorithm has gone through a number of version updates since it was first released in July 2005. Previous version...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965929

    authors: Salomons G,Kerr A,Mei X,Patel D

    更新日期:2008-07-01 00:00:00

  • Sci-Fri PM: Planning-03: Fundamental understanding of the inter-relation of arc range, angular dose rate and MLC leaf position optimization of Intensity Modulated Arc Therapy for a concave target.

    abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965975

    authors: Oliver M,Chen J,Wong E

    更新日期:2008-07-01 00:00:00

  • Beam properties and stability of a flattening-filter free 7 MV beam-an overview.

    abstract:PURPOSE:Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). METHODS:Dosimetric properties of the 7XU beam were measured in May a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3703835

    authors: Dzierma Y,Licht N,Nuesken F,Ruebe C

    更新日期:2012-05-01 00:00:00

  • Validating FMEA output against incident learning data: A study in stereotactic body radiation therapy.

    abstract:PURPOSE:Though failure mode and effects analysis (FMEA) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge, its output has never been validated against data on errors that actually occur. The objective of this study was to perform FMEA of a stereotactic body radiation therapy (SB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4919440

    authors: Yang F,Cao N,Young L,Howard J,Logan W,Arbuckle T,Sponseller P,Korssjoen T,Meyer J,Ford E

    更新日期:2015-06-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00

  • SU-E-T-476: GPU-Based Monte Carlo Radiotherapy Dose Calculation Using Phase- Space Sources.

    abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735565

    authors: Townson R,Jia X,Zavgorodni S,Jiang S

    更新日期:2012-06-01 00:00:00

  • Angular measurement of the cobalt-60 emitted radiation spectrum from a radiosurgery irradiator.

    abstract::The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1355305

    authors: Drzymala RE,Sohn JW,Guo C,Sobotka LG,Purdy JA

    更新日期:2001-04-01 00:00:00

  • X-ray-transmission computed tomography.

    abstract::The immediate goal of clinically based x-ray-transmission computed tomography (CT) is to provide a measurement of the x-ray linear attenuation coefficient in cross section with the ultimate goal of impacting on patient management and care. To do this with the accuracy needed for clinical goals requires the careful int...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.594381

    authors: McCullough EC,Payne JT

    更新日期:1977-03-01 00:00:00

  • Fast contour propagation for MR-guided prostate radiotherapy using convolutional neural networks.

    abstract:PURPOSE:To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS:Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13994

    authors: Eppenhof KAJ,Maspero M,Savenije MHF,de Boer JCJ,van der Voort van Zyp JRN,Raaymakers BW,Raaijmakers AJE,Veta M,van den Berg CAT,Pluim JPW

    更新日期:2020-03-01 00:00:00

  • Improving the calibration of radiochromic films by the use of uncertainties in optical density and dose.

    abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811238

    authors: Garcia LI,Azorin JF

    更新日期:2013-07-01 00:00:00

  • Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy.

    abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598479

    authors: Allen DA,Beynon TD,Green S

    更新日期:1999-01-01 00:00:00