Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation.

Abstract:

:An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam profile or to simultaneously determine the scanning beam profile and the leaf motions required to generate the desired intensity profile, which minimize the total treatment time. The limitations imposed by the physics of an elementary beam are taken into account. The algorithm is an iterative one, with typical calculation times being of the order of a few milliseconds.

journal_name

Med Phys

journal_title

Medical physics

authors

Spirou SV,Chui CS

doi

10.1118/1.597672

subject

Has Abstract

pub_date

1996-01-01 00:00:00

pages

1-8

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

23

pub_type

杂志文章
  • MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735777

    authors: Andriole K

    更新日期:2012-06-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • Poster - Thur Eve - 77: Coordinate transformation from DICOM to DOSXYZnrc.

    abstract::DICOM format is the de facto standard for communications between therapeutic and diagnostic modalities. A plan generated by a treatment planning system (TPS) is often exported to DICOM format. BEAMnrc/DOSXYZnrc is a widely used Monte Carlo (MC) package for beam and dose simulations in radiotherapy. It has its own defi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740186

    authors: Zhan L,Jiang R,Osei EK

    更新日期:2012-07-01 00:00:00

  • WE-G-BRB-03: On the Detectability of Jaw Decalibrations with the DAVID System.

    abstract:PURPOSE:To evaluate if the recently described problems with the calibration of jaws at Varian linear accelerators can be detected with the DAVID system. METHODS:Recently Varian Clinac field size issues resulted in a widespread medical device correction notice, stating that incorrect jaw positioning due to excessive co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736189

    authors: Poppe B,Looe H,Harder D

    更新日期:2012-06-01 00:00:00

  • Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies.

    abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598268

    authors: Wickman G,Johansson B,Bahar-Gogani J,Holmström T,Grindborg JE

    更新日期:1998-06-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • A piecewise-focused high DQE detector for MV imaging.

    abstract:PURPOSE:Electronic portal imagers (EPIDs) with high detective quantum efficiencies (DQEs) are sought to facilitate the use of the megavoltage (MV) radiotherapy treatment beam for image guidance. Potential advantages include high quality (treatment) beam's eye view imaging, and improved cone-beam computed tomography (CB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927786

    authors: Star-Lack J,Shedlock D,Swahn D,Humber D,Wang A,Hirsh H,Zentai G,Sawkey D,Kruger I,Sun M,Abel E,Virshup G,Shin M,Fahrig R

    更新日期:2015-09-01 00:00:00

  • Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching.

    abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597344

    authors: van Herk M,Kooy HM

    更新日期:1994-07-01 00:00:00

  • Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

    abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3312435

    authors: Le Huy Q,Ducote JL,Molloi S

    更新日期:2010-03-01 00:00:00

  • Comparison of breast density measured on MR images acquired using fat-suppressed versus nonfat-suppressed sequences.

    abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3646756

    authors: Chang DH,Chen JH,Lin M,Bahri S,Yu HJ,Mehta RS,Nie K,Hsiang DJ,Nalcioglu O,Su MY

    更新日期:2011-11-01 00:00:00

  • SU-E-J-186: CT Textures Can be Predictive for Tumor Shrinkage.

    abstract:PURPOSE:To determine if NSCLC GTV CT textures can be predictive for tumor shrinkage after proton therapy with concurrent chemotherapy. METHODS:Simulation and weekly 4DCTs were obtained from 25 patients with locally advanced NSCLC treated by proton therapy at a 74 Gy dose level with concurrent chemotherapy. In-house de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735027

    authors: Hunter L,Chen Y,Zhang L,Liao Z,Dong L,Court L

    更新日期:2012-06-01 00:00:00

  • The use of a priori information in the detection of mammographic microcalcifications to improve their classification.

    abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1559884

    authors: Salfity MF,Nishikawa RM,Jiang Y,Papaioannou J

    更新日期:2003-05-01 00:00:00

  • Computational analysis and dosimetric evaluation of a commercial irregular-fields computer program.

    abstract::The proper evaluation of the accuracy of a new computer program for radiation-therapy dosimetry requires consideration of both the mathematical algorithm used in the program and the performance required in clinical applications. As an example, our evaluation of the irregular-fields dosimetry program currently marketed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594344

    authors: Hallberg JR,Ibbott GS,Carson PL,Hendee WR

    更新日期:1977-11-01 00:00:00

  • A pencil beam algorithm for magnetic resonance image-guided proton therapy.

    abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12854

    authors: Padilla-Cabal F,Georg D,Fuchs H

    更新日期:2018-05-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams.

    abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597960

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-11-01 00:00:00

  • Transrectal ultrasound based prostate volume determination: is the frustum algorithm more accurate than planimetry?

    abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4789920

    authors: Liu D,Usmani N,Sloboda RS

    更新日期:2013-03-01 00:00:00

  • SU-E-T-217: Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans.

    abstract:PURPOSE:To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS:We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735279

    authors: Atwood T,Xing L,Hristov D

    更新日期:2012-06-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • Evaluation of edge effect due to phase contrast imaging for mammography.

    abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1992087

    authors: Matsuo S,Katafuchi T,Tohyama K,Morishita J,Yamada K,Fujita H

    更新日期:2005-08-01 00:00:00

  • SU-E-T-619: A Network-Flow Solution Approach to VMAT Treatment Plan Optimization.

    abstract:PURPOSE:To add mathematical rigor to the merging phase of the recently published two-stage VMAT optimization method called VMERGE. Using an exact merging method, we are able to better characterize the tradeoff between delivery efficiency and dose quality. METHODS:VMERGE begins with an IMRT plan that uses 180 equi-spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735709

    authors: Salari E,Craft D

    更新日期:2012-06-01 00:00:00

  • Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    abstract:PURPOSE:X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12997

    authors: Vernekohl D,Tzoumas S,Zhao W,Xing L

    更新日期:2018-05-25 00:00:00

  • Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.

    abstract:PURPOSE:When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14139

    authors: Geoghegan TJ,Nelson NP,Flynn RT,Hill PM,Rana S,Hyer DE

    更新日期:2020-07-01 00:00:00

  • Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography.

    abstract:PURPOSE:Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658738

    authors: Nowak T,Hupfer M,Brauweiler R,Eisa F,Kalender WA

    更新日期:2011-12-01 00:00:00

  • Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.

    abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4893278

    authors: Altunbas C,Lai CJ,Zhong Y,Shaw CC

    更新日期:2014-09-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Technical Note: Gray tracking in medical color displays-A report of Task Group 196.

    abstract:PURPOSE:The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. METHODS:The authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953186

    authors: Badano A,Wang J,Boynton P,Le Callet P,Cheng WC,Deroo D,Flynn MJ,Matsui T,Penczek J,Revie C,Samei E,Steven PM,Swiderski S,Van Hoey G,Yamaguchi M,Hasegawa M,Nagy BV

    更新日期:2016-07-01 00:00:00

  • Four-dimensional computed tomography: image formation and clinical protocol.

    abstract::Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1869852

    authors: Rietzel E,Pan T,Chen GT

    更新日期:2005-04-01 00:00:00