Abstract:
:To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and kernel hardening correction methods were also compared to the existing approaches including terma divergence correction, dose divergence correction methods, and the effective mean kernel method with no kernel hardening correction. Treatment fields of 10 x 10-40 x 40 cm2 (field size at source to axis distance (SAD)) with source to source distances (SSDs) of 60, 80, and 100 cm, and photon energies of 6, 10, and 18 MV have been studied. Our results showed that based on the relative dose errors at a depth of 15 cm along the central axis, the terma divergence correction may be used for fields smaller than 10 x 10 cm2 with a SSD larger than 80 cm; the dose divergence correction with an additional kernel hardening correction can reduce dose error and may be more applicable than the terma divergence correction. For both these methods, the dose error increased linearly with the depth in the phantom; the 90% isodose lines at the depth of 15 cm were shifted by about 2%-5% of the field width due to significant underestimation of the penumbra dose. The kernel hardening effect was less prominent than the kernel tilting effect for clinical photon beams. The dose error by using nonhardening corrected kernel is less than 2.0% at a depth of 15 cm along the central axis, yet it increased with a smaller field size and lower photon energy. The kernel hardening correction could be more important to compute dose in the fields with beam modifiers such as wedges when beam hardening is more significant. The kernel tilting correction and kernel hardening correction increased computation time by about 3 times, and 0.5-1 times, respectively. This can be justified by more accurate dose calculations for the majority of clinical treatments.
journal_name
Med Physjournal_title
Medical physicsauthors
Liu HH,Mackie TR,McCullough ECdoi
10.1118/1.597960subject
Has Abstractpub_date
1997-11-01 00:00:00pages
1729-41issue
11eissn
0094-2405issn
2473-4209journal_volume
24pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Examine the use of TomoDose for Tomotherapy quality assurance. METHODS:Baseline TomoDose profiles are acquired annually in accordance with TG-148. During monthly quality assurance, TomoDose is irradiated with a static beam and referenced to baseline. Differences between superimposed profiles are evaluated mont...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735202
更新日期:2012-06-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735792
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822621
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13958
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3271107
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:Intensity Modulated Neutron Radiotherapy (IMNRT) has been commissioned for clinical use. The number of allowable segments in IMNRT plans is limited by MLC speed. Quality and deliverability of static IMNRT treatment plans using the TG-119 test suite were evaluated to establish guidelines for the number of segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735662
更新日期:2012-06-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract::Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2975147
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773883
更新日期:2013-02-01 00:00:00
abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2201147
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:A novel 3D printing method has been developed, which employs human CT images to construct patient specific phantoms by controlling the filament extrusion rate. METHODS:An in-house software was developed comprising pixel-by-pixel (PbP) reading of the Hounsfield Units (HU) values in the original patient DICOM im...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13154
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3447727
更新日期:2010-07-01 00:00:00
abstract::The surface radio frequency (rf) power absorption in human head and torso nuclear magnetic resonance (NMR) imaging experiments is estimated. The results are expressed as a function of the NMR frequency, the rf pulse length, and the pulse duty cycle, which are varied over six orders of magnitude for general applicabili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595000
更新日期:1981-07-01 00:00:00
abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13763
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905104
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13246
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This lead...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4711753
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12672
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1002/mp.12634
更新日期:2018-01-01 00:00:00
abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594910
更新日期:1981-01-01 00:00:00
abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897567
更新日期:2014-11-01 00:00:00
abstract::When a catheter is inserted through an artery, the wall shear stress increases and the secondary flow exhibits an increased number of instantaneous vortices. These effects become more evident when the annular gap between the catheter and the artery becomes more narrow. Accordingly it is suggested that these factors ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596448
更新日期:1990-09-01 00:00:00
abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12164
更新日期:2017-05-01 00:00:00
abstract:PURPOSE:Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4890091
更新日期:2014-08-01 00:00:00
abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1992087
更新日期:2005-08-01 00:00:00
abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597654
更新日期:1995-12-01 00:00:00