SU-E-T-144: Daily and Monthly Quality Assurance with TomoDose.

Abstract:

PURPOSE:Examine the use of TomoDose for Tomotherapy quality assurance. METHODS:Baseline TomoDose profiles are acquired annually in accordance with TG-148. During monthly quality assurance, TomoDose is irradiated with a static beam and referenced to baseline. Differences between superimposed profiles are evaluated monthly. TomoDose is further utilized in verifying transverse laser alignment. The TomoDose is aligned to virtual isocenter lasers and statically irradiated with a 40cm × 5.02cm treatment beam. Next, the TomoDose's internal diodes are imaged using the MVCT. Transverse laser, imaging beam, and treatment beam field center are verified to less than 1mm coincidence difference. For daily TomoDose irradiation the couch is set to a fixed height and irradiated. The dose to the central axis and dose rate is recorded. To check energy, the measurement is repeated with an aluminum block placed centrally on the TomoDose. The output reading relative to the dose rate is compared to the baseline determined at the time of monthly verification. A ratio of the output and energy readings serves as a daily energy constancy check. RESULTS:Over 28 months, for nominal field sizes of 1.05, 2.50, and 5.02cm, TomoDose measured an average field size of 1.10, 2.51, and 5.02cm with maximum deviations of 0.09, 0.09, and 0.10cm, respectively. For transverse laser alignment, TomoDose software calculates beam center location. We have found the alignment to be sensitive to sub-millimeter changes. Our nominal daily energy ratio is 0.689. We have observed a decline from an estimated 0.693 to 0.680 with target wear, providing a good indicator of degradation. CONCLUSIONS:TomoDose serves as a reliable constancy device with added benefits of verifying transverse laser alignment and predicting target health. I own common stock in Accuray (Tomotherapy).

journal_name

Med Phys

journal_title

Medical physics

authors

Terrell J

doi

10.1118/1.4735202

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3736

issue

6Part11

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • Phantoms with 10BF3 detectors for boron neutron capture therapy applications.

    abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598354

    authors: Alburger DE,Raparia D,Zucker MS

    更新日期:1998-09-01 00:00:00

  • Direction modulated brachytherapy (DMBT) for treatment of cervical cancer: A planning study with 192 Ir, 60 Co, and 169 Yb HDR sources.

    abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12598

    authors: Safigholi H,Han DY,Mashouf S,Soliman A,Meigooni AS,Owrangi A,Song WY

    更新日期:2017-12-01 00:00:00

  • The Cole relaxation frequency as a parameter to identify cancer in breast tissue.

    abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4725172

    authors: Gregory WD,Marx JJ,Gregory CW,Mikkelson WM,Tjoe JA,Shell J

    更新日期:2012-07-01 00:00:00

  • Experimental verification of a technique for predicting scattered radiation transfer: application to low photon energies.

    abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595807

    authors: Bernstein H,Muntz EP

    更新日期:1986-11-01 00:00:00

  • Validating FMEA output against incident learning data: A study in stereotactic body radiation therapy.

    abstract:PURPOSE:Though failure mode and effects analysis (FMEA) is becoming more widely adopted for risk assessment in radiation therapy, to our knowledge, its output has never been validated against data on errors that actually occur. The objective of this study was to perform FMEA of a stereotactic body radiation therapy (SB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4919440

    authors: Yang F,Cao N,Young L,Howard J,Logan W,Arbuckle T,Sponseller P,Korssjoen T,Meyer J,Ford E

    更新日期:2015-06-01 00:00:00

  • Introduction of a novel dose saving acquisition mode for the PortalVision aS500 EPID to facilitate on-line patient setup verification.

    abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1668391

    authors: Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini R

    更新日期:2004-04-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • A method for physically based radiotherapy optimization with intelligent tissue weight determination.

    abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1428756

    authors: Jones L,Hoban P

    更新日期:2002-01-01 00:00:00

  • Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    abstract:PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938066

    authors: Liu Y,Yin FF,Rhee D,Cai J

    更新日期:2016-01-01 00:00:00

  • WE-G-217BCD-10: Shading Correction in Image Domain for Cone-Beam CT Without Prior Information.

    abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736218

    authors: Fan Q,Niu T,Zhu L

    更新日期:2012-06-01 00:00:00

  • A regional convolution kernel algorithm for scatter correction in dual-energy images: comparison to single-kernel algorithms.

    abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597297

    authors: Kruger DG,Zink F,Peppler WW,Ergun DL,Mistretta CA

    更新日期:1994-02-01 00:00:00

  • TU-D-213AB-01: How You Can Be the Speaker and Communicator Everyone Wants You to Be.

    abstract::Effectiveness of an oral presentation depends on the ability of the speaker to communicate with the audience. An important part of this communication is focusing on two to five key points and emphasizing those points during the presentation. Every aspect of the presentation should be purposeful and directed at facilit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735944

    authors: Collins J,Aydogan B

    更新日期:2012-06-01 00:00:00

  • Measured electron energy and angular distributions from clinical accelerators.

    abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597817

    authors: Deasy JO,Almond PR,McEllistrem MT

    更新日期:1996-05-01 00:00:00

  • Characterizing the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations.

    abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4819816

    authors: Seco J,Oumano M,Depauw N,Dias MF,Teixeira RP,Spadea MF

    更新日期:2013-09-01 00:00:00

  • SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

    abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2937652

    authors: Li D,Zhao W

    更新日期:2008-07-01 00:00:00

  • Wedge-shaped dose distributions by computer-controlled collimator motion.

    abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594440

    authors: Kijewski PK,Chin LM,Bjärngard BE

    更新日期:1978-09-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT).

    abstract:PURPOSE:To develop a novel aperture-based algorithm for volumetric modulated are therapy (VMAT) treatment plan optimization with high quality and high efficiency. METHODS:The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3491675

    authors: Men C,Romeijn HE,Jia X,Jiang SB

    更新日期:2010-11-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • Dose optimization in pediatric cardiac x-ray imaging.

    abstract:PURPOSE:The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488911

    authors: Gislason AJ,Davies AG,Cowen AR

    更新日期:2010-10-01 00:00:00

  • SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4.

    abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734794

    authors: Kapadia A,Samei E,Harrawood B,Sahbaee P,Chawla A,Tan Z,Brady D

    更新日期:2012-06-01 00:00:00

  • Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles.

    abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12893

    authors: Dunning CAS,Bazalova-Carter M

    更新日期:2018-06-01 00:00:00

  • Calculation of the radiological depth.

    abstract::The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595739

    authors: Siddon RL

    更新日期:1985-01-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.

    abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14347

    authors: Harms J,Lei Y,Wang T,McDonald M,Ghavidel B,Stokes W,Curran WJ,Zhou J,Liu T,Yang X

    更新日期:2020-09-01 00:00:00

  • A comparison of reconstruction algorithms for C-arm mammography tomosynthesis.

    abstract::Digital tomosynthesis is an imaging technique to produce a tomographic image from a series of angular digital images in a manner similar to conventional focal plane tomography. Unlike film focal plane tomography, the acquisition of the data in a C-arm geometry causes the image receptor to be positioned at various angl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2219090

    authors: Rakowski JT,Dennis MJ

    更新日期:2006-08-01 00:00:00