Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

Abstract:

PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volume, coupled with an adapted segmentation procedure and a distance map, allows us to minimize the number of boundary crossings, which slows down simulation. The method was implemented with the GEANT4 toolkit and compared to four other methods: One box per voxel, parameterized volumes, octree-based volumes, and nested parameterized volumes. For each representation, we compared dose distribution, time, and memory consumption. RESULTS:The proposed method allows us to decrease computational time by up to a factor of 15, while keeping memory consumption low, and without any modification of the transportation engine. Speeding up is related to the geometry complexity and the number of different materials used. We obtained an optimal number of steps with removal of all unnecessary steps between adjacent voxels sharing a similar material. However, the cost of each step is increased. When the number of steps cannot be decreased enough, due for example, to the large number of material boundaries, such a method is not considered suitable. CONCLUSION:This feasibility study shows that optimizing the representation of an image in memory potentially increases computing efficiency. We used the GEANT4 toolkit, but we could potentially use other Monte Carlo simulation codes. The method introduces a tradeoff between speed and geometry accuracy, allowing computational time gain. However, simulations with GEANT4 remain slow and further work is needed to speed up the procedure while preserving the desired accuracy.

journal_name

Med Phys

journal_title

Medical physics

authors

Sarrut D,Guigues L

doi

10.1118/1.2884854

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

1452-63

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • An externally and internally deformable, programmable lung motion phantom.

    abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918581

    authors: Cheung Y,Sawant A

    更新日期:2015-05-01 00:00:00

  • Calibration of 192Ir high-dose-rate afterloading systems.

    abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596649

    authors: Goetsch SJ,Attix FH,Pearson DW,Thomadsen BR

    更新日期:1991-05-01 00:00:00

  • Scan pattern optimization for uniform proton beam scanning.

    abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158731

    authors: Anferov VA

    更新日期:2009-08-01 00:00:00

  • SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4.

    abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734794

    authors: Kapadia A,Samei E,Harrawood B,Sahbaee P,Chawla A,Tan Z,Brady D

    更新日期:2012-06-01 00:00:00

  • Numerical and experimental investigation of impacts of nonlinear scattering encapsulated microbubbles on Nakagami distribution.

    abstract:PURPOSE:The Nakagami statistical model and Nakagami shape parameter m have been widely used in linear tissue characterization and preliminarily characterized the envelope distributions of nonlinear encapsulated microbubbles (EMBs). However, the Nakagami distribution of nonlinear scattering EMBs lacked a systematical in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13833

    authors: Wang D,Sang Y,Zhang X,Hu H,Lu S,Zhang Y,Fu C,Cloutier G,Wan M

    更新日期:2019-12-01 00:00:00

  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • Dosimetric properties of neutrons from 21-MeV deuteron bombardment of a deuterium gas target.

    abstract::Spectra, yields, average energies, and kerma rates in tissue of neutrons from 21-MeV deuteron bombardment of deuterium gas targets have been calculated for target thicknesses of 1, 3.5, and 5 MeV. A high pressure gas cell was constructed and was filled with 33 atm of D2 gas (equivalent to an energy loss of 3.5 MeV for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594561

    authors: Weaver KA,Eenmaa J,Bichsel H,Wootton P

    更新日期:1979-05-01 00:00:00

  • Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments.

    abstract:PURPOSE:To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. METHODS:Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729738

    authors: Mancuso GM,Fontenot JD,Gibbons JP,Parker BC

    更新日期:2012-07-01 00:00:00

  • Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.

    abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594746

    authors: Bjärngard BE,Kase KR,Rudén BI,Biggs PJ,Boyer AL,Johansson KA

    更新日期:1980-09-01 00:00:00

  • MO-F-213AB-01: Improving Dose Uniformity in Patch-Field Proton Therapy Using Beam Current Modulation.

    abstract:PURPOSE:To improve the dose homogeneity in patch-field proton therapy using beam current modulation. METHODS:MCNPX simulations were performed for various configurations of the Mevion S250 beamline. Spread-out Bragg peak (SOBP) dose distributions were calculated, and lateral and distal dose profiles were extracted for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735806

    authors: Hill P,Klein E,Bloch C

    更新日期:2012-06-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Determining the energy spectrum of clinical linear accelerator using an optimized photon beam transmission protocol.

    abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13569

    authors: Choi HJ,Park H,Yi CY,Kim BC,Shin WG,Min CH

    更新日期:2019-07-01 00:00:00

  • 3D image-guided robotic needle positioning system for small animal interventions.

    abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4771958

    authors: Bax JS,Waring CS,Sherebrin S,Stapleton S,Hudson TJ,Jaffray DA,Lacefield JC,Fenster A

    更新日期:2013-01-01 00:00:00

  • 3D modeling of effects of increased oxygenation and activity concentration in tumors treated with radionuclides and antiangiogenic drugs.

    abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615164

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2011-08-01 00:00:00

  • Penalized likelihood fluence optimization with evolutionary components for intensity modulated radiation therapy treatment planning.

    abstract::A novel iterative penalized likelihood algorithm with evolutionary components for the optimization of beamlet fluences for intensity modulated radiation therapy (IMRT) is presented. This algorithm is designed to be flexible in terms of the objective function and automatically escalates dose, as long as the objective f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1773631

    authors: Baydush AH,Marks LB,Das SK

    更新日期:2004-08-01 00:00:00

  • Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

    abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826159

    authors: Nelson G,Yoon S,Krishna G,Wilfley B,Fahrig R

    更新日期:2013-11-01 00:00:00

  • Dose sculpting with generalized equivalent uniform dose.

    abstract::With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1897464

    authors: Wu Q,Djajaputra D,Liu HH,Dong L,Mohan R,Wu Y

    更新日期:2005-05-01 00:00:00

  • Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries.

    abstract:PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limitin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14185

    authors: Lim-Reinders S,Keller BM,Sahgal A,Chugh B,Kim A

    更新日期:2020-07-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    abstract::Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1328081

    authors: Seuntjens JP,Ross CK,Shortt KR,Rogers DW

    更新日期:2000-12-01 00:00:00

  • Combined mixed approach algorithm for in-line phase-contrast x-ray imaging.

    abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3447727

    authors: De Caro L,Scattarella F,Giannini C,Tangaro S,Rigon L,Longo R,Bellotti R

    更新日期:2010-07-01 00:00:00

  • Evaluation of the Gafchromic(®) EBT2 film for the dosimetry of radiosurgical beams.

    abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752211

    authors: Larraga-Gutierrez JM,Garcia-Hernandez D,Garcia-Garduno OA,Galvan de la Cruz OO,Ballesteros-Zebadua P,Esparza-Moreno KP

    更新日期:2012-10-01 00:00:00

  • Diagnostic efficacy of computer extracted image features in optical coherence tomography of the precancerous cervix.

    abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523098

    authors: Kang W,Qi X,Tresser NJ,Kareta M,Belinson JL,Rollins AM

    更新日期:2011-01-01 00:00:00

  • A clinically feasible method for the detection of potential collision in proton therapy.

    abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760988

    authors: Zou W,Lin H,Plastaras JP,Wang H,Bui V,Vapiwala N,McDonough J,Tochner Z,Both S

    更新日期:2012-11-01 00:00:00

  • Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

    abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12425

    authors: Fung GSK,Ciuffo L,Ashikaga H,Taguchi K

    更新日期:2017-09-01 00:00:00

  • Effective point of measurement of thimble ion chambers in megavoltage photon beams.

    abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3266750

    authors: Tessier F,Kawrakow I

    更新日期:2010-01-01 00:00:00

  • Novel methods of measuring single scan dose profiles and cumulative dose in CT.

    abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1835571

    authors: Nakonechny KD,Fallone BG,Rathee S

    更新日期:2005-01-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00