SU-E-T-573: Quality and Deliverability of Intensity Modulated Neutron Radiotherapy (IMNRT) Plans.

Abstract:

PURPOSE:Intensity Modulated Neutron Radiotherapy (IMNRT) has been commissioned for clinical use. The number of allowable segments in IMNRT plans is limited by MLC speed. Quality and deliverability of static IMNRT treatment plans using the TG-119 test suite were evaluated to establish guidelines for the number of segments per plan. METHODS:Treatment plans were created and optimized to specified constraints for all cases in the TG-119 test suite using the Varian Eclipse TPS. A 4MV photon beam with similar penetration characteristics as the fast neutron beam was used as a surrogate for this optimization. Final dose calculations were performed using an in-house TPS commissioned for neutron dose calculations. Following optimization, MLC segments were created for three ranges of total plan complexity - very limited (15-23 segments), limited (24- 31 segments), and unlimited. Calculated DVHs were then compared for compliance with TG-119 dose constraints. The estimated time of delivery for plans in each range was calculated based on known delivery parameters. RESULTS:The prostate case passes all constraints for each complexity level. All other plans fail to meet at least one constraint for one or more of the complexity levels. For all cases combined, the very limited, limited, and unlimited complexity levels meet 16, 17, and 19 of 23 total dose constraints, respectively. The mean estimated delivery time for the very limited, limited, and unlimited plans is 34 minutes (range: 27-39), 40 minutes (range: 34-45), and 68 minutes (range: 53-81) respectively, neglecting any delay due to therapists entering the treatment room. CONCLUSION:IMNRT plan quality is limited by current MLC capabilities. IMNRT plans should be limited to 25 segments to ensure a reasonable treatment time of 45 minutes. Even with this small number of segments, we were able to meet most dose constraints set forth in TG-119.

journal_name

Med Phys

journal_title

Medical physics

authors

Spink R,Burmeister J,Bossenberger T,Snyder M

doi

10.1118/1.4735662

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3837

issue

6Part19

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Calculation of photon dose distributions in an inhomogeneous medium using convolutions.

    abstract::A formulation of the single energy photon transport problem is cast in the form of a series of convolutions over the primary fluence distribution with invariant kernels. A method is developed for compensating for the variant intervoxel attenuation in the scattered dose distribution by means of an invariant correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595964

    authors: Boyer AL,Mok EC

    更新日期:1986-07-01 00:00:00

  • An externally and internally deformable, programmable lung motion phantom.

    abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918581

    authors: Cheung Y,Sawant A

    更新日期:2015-05-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • Quasi real time in vivo dosimetry for VMAT.

    abstract:PURPOSE:Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875685

    authors: Fidanzio A,Porcelli A,Azario L,Greco F,Cilla S,Grusio M,Balducci M,Valentini V,Piermattei A

    更新日期:2014-06-01 00:00:00

  • Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system.

    abstract:PURPOSE:Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. METHODS:In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion dat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3254189

    authors: Marxen M,Marmurek J,Baker N,Graham SJ

    更新日期:2009-12-01 00:00:00

  • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

    abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734726

    authors: Poludniowski GG

    更新日期:2007-06-01 00:00:00

  • Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects.

    abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930798

    authors: Bouchard H,Kamio Y,Palmans H,Seuntjens J,Duane S

    更新日期:2015-10-01 00:00:00

  • Development of optical process for accessing three-dimensional patient topology.

    abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594447

    authors: Lerch IA,Barish RJ,Stern H

    更新日期:1978-11-01 00:00:00

  • Practical cone-beam lambda tomography.

    abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2348767

    authors: Yu H,Ye Y,Wang G

    更新日期:2006-10-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

    abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1598851

    authors: Liu L,Bassano DA,Prasad SC,Keshler BL,Hahn SS

    更新日期:2003-09-01 00:00:00

  • Poster - Thurs Eve-10: The accuracy of MU calculations for enhanced dynamic wedge with the Varian's anisotropic analytical algorithm.

    abstract::The Anisotropic Analytical Algorithm (AAA) of the Varian Eclipse treatment planning system calculates absolute dose for a variety of beam settings including those with an enhanced dynamic wedge (EDW). This algorithm has gone through a number of version updates since it was first released in July 2005. Previous version...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965929

    authors: Salomons G,Kerr A,Mei X,Patel D

    更新日期:2008-07-01 00:00:00

  • On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA.

    abstract:PURPOSE:To investigate using 3D γ analysis for IMRT and VMAT QA. METHODS:We explored and studied 3D γ-analysis by comparing TPS computed and EPID back-projection reconstructed doses in patient's CT images. Two 3D γ quantities, γ(PTV) and γ(10), were proposed and studied for evaluating the QA results, and compared to 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4711755

    authors: Wu C,Hosier KE,Beck KE,Radevic MB,Lehmann J,Zhang HH,Kroner A,Dutton SC,Rosenthal SA,Bareng JK,Logsdon MD,Asche DR

    更新日期:2012-06-01 00:00:00

  • Sci-Fri AM: Imaging - 05: Cone-beam computed tomography for breast biopsy analysis: Simulations.

    abstract:PURPOSE:To determine the feasibility and potential utility of cone beam CT on breast biopsies. METHODS:CBCT simulations were done with a setup which emulates an MX-20 digital specimen radiography system (Faxitron X-Ray Corporation, Chicago, IL), albeit a DQE = 1 was assumed. The phantom consisted of a 5mm diameter cyl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740191

    authors: Laamanen C,LeClair R

    更新日期:2012-07-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

    abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388219

    authors: Olivo A,Arfelli F,Cantatore G,Longo R,Menk RH,Pani S,Prest M,Poropat P,Rigon L,Tromba G,Vallazza E,Castelli E

    更新日期:2001-08-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method for concave targets.

    abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3173815

    authors: Hoegele W,Loeschel R,Zygmanski P

    更新日期:2009-08-01 00:00:00

  • Evaluation of video gray-scale display.

    abstract::Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596846

    authors: Nawfel RD,Chan KH,Wagenaar DJ,Judy PF

    更新日期:1992-05-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • "Battered data"--some clinical effects of the abuse of multiple regression methods: the NSD.

    abstract::The NSD equation, D = 1850 x T0.11 x N0.24, is a celebrated transmogrification of Cohen's two well-known collations of data on response to clinical irradiations (3 degrees erythema and 0.90 ablation of skin cancer) in which the relation of D and T is fixed by the data selected by Cohen and the additional constraint th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595034

    authors: Herbert DE Jr

    更新日期:1981-11-01 00:00:00

  • Accelerated helium-ion beams for radiotherapy and stereotactic radiosurgery.

    abstract::A new beam line for radiotherapy and radiosurgery with accelerated helium-ion beams has been set up at the Bevalac. The new treatment room has been equipped with a very precise patient positioner in order to utilize the superior dose localization properties of light-ion beams. The beam spreading and shaping system is ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596696

    authors: Ludewigt BA,Chu WT,Phillips MH,Renner TR

    更新日期:1991-01-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • Accuracy of EGSnrc calculations at 60Co energies for the response of ion chambers configured with various wall materials and cavity dimensions.

    abstract::In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at 60Co energies. Calculations of the ratios of response per unit mass of air as a function of cav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3013701

    authors: La Russa DJ,Rogers DW

    更新日期:2008-12-01 00:00:00

  • Effect of patient support pads on image quality and dose in fluoroscopy.

    abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597906

    authors: Geiser WR,Huda W,Gkanatsios NA

    更新日期:1997-03-01 00:00:00

  • Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function.

    abstract::The assessment of differential left and right lung function is important for patients under consideration for lung resection procedures such as single lung transplantation. We developed an automated, knowledge-based segmentation algorithm for purposes of deriving functional information from dynamic computed tomography...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598898

    authors: Brown MS,Goldin JG,McNitt-Gray MF,Greaser LE,Sapra A,Li KT,Sayre JW,Martin K,Aberle DR

    更新日期:2000-03-01 00:00:00