On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA.

Abstract:

PURPOSE:To investigate using 3D γ analysis for IMRT and VMAT QA. METHODS:We explored and studied 3D γ-analysis by comparing TPS computed and EPID back-projection reconstructed doses in patient's CT images. Two 3D γ quantities, γ(PTV) and γ(10), were proposed and studied for evaluating the QA results, and compared to 2D γ (MapCheck composite: γ(MC)). RESULTS:It was found that when 3%(global)/3 mm criteria was used, all IMRT and 90% of VMAT plans passed QA with a γ pass rate ≥90%. A significant statistical correlation was observed between 3D and 2D γ-analysis results for IMRT QA if γ(10) and γ(MC) are concerned, but no significant relation is found between γ(PTV) and γ(MC). CONCLUSIONS:3D γ analysis based on EPID dose back-projection may provide a feasible tool for IMRT and VMAT pretreatment plan QA.

journal_name

Med Phys

journal_title

Medical physics

authors

Wu C,Hosier KE,Beck KE,Radevic MB,Lehmann J,Zhang HH,Kroner A,Dutton SC,Rosenthal SA,Bareng JK,Logsdon MD,Asche DR

doi

10.1118/1.4711755

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3051-9

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Dosimetry of a thyroid uptake detected in seed migration survey following a patient's iodine-125 prostate implant and in vitro measurements of intentional seed leakages.

    abstract::As a quality control procedure, a post-implant seed migration survey has been accomplished on 340 prostate cancer patients since November 2001. Pulmonary seed embolization and intracardiac seed embolization have been detected. A case of thyroid uptake due to leaking iodine-125 (I-125) sources was also seized. In order...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207319

    authors: Chen QS,Russell JL Jr,Macklis RR,Weinhous MS,Blair HF

    更新日期:2006-07-01 00:00:00

  • Evaluations of magnetic resonance imaging parameters with simple phantoms.

    abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595894

    authors: Brateman L,Jennings LW,Nunnally RL,Vaughan JT

    更新日期:1986-07-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories.

    abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13887

    authors: MacDonald RL,Syme A,Little B,Ward L,Thomas CG

    更新日期:2020-02-01 00:00:00

  • Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera.

    abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596838

    authors: Manglos SH,Capone RB,Bassano DA

    更新日期:1992-03-01 00:00:00

  • Quantification of breast density with dual energy mammography: a simulation study.

    abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002308

    authors: Ducote JL,Molloi S

    更新日期:2008-12-01 00:00:00

  • SU-E-T-635: Effect of Planning Parameters on Tomotherapy Dosimetric Quality and Treatment Efficiency.

    abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735724

    authors: Lian J,Burkhardt K,Chera B,Chang S

    更新日期:2012-06-01 00:00:00

  • Beam shaper with optimized dose utility for helical cone-beam CT.

    abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577766

    authors: Köhler T,Brendel B,Proksa R

    更新日期:2011-07-01 00:00:00

  • Determination of primary dose in 60Co gamma beam using a small attenuator.

    abstract::A measurement technique previously proposed for determining dose from primary radiation has been tested using 60Co gamma rays. It is shown that the dose from primary radiation is reliably determined for field sizes of 10 X 10 and 20 X 20 cm2 at depths of 0.5, 5, and 10 cm in water. With further development this techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596534

    authors: Nizin PS,Kase KR

    更新日期:1990-01-01 00:00:00

  • Automated matching and segmentation of lymphoma on serial CT examinations.

    abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2404617

    authors: Yan J,Zhao B,Curran S,Zelenetz A,Schwartz LH

    更新日期:2007-01-01 00:00:00

  • Semiautomated four-dimensional computed tomography segmentation using deformable models.

    abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929207

    authors: Ragan D,Starkschall G,McNutt T,Kaus M,Guerrero T,Stevens CW

    更新日期:2005-07-01 00:00:00

  • Dosimetric aspects of a 3.3-MV linear accelerator.

    abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596487

    authors: Steidley KD,Rosen CW

    更新日期:1990-05-01 00:00:00

  • The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.

    abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822736

    authors: Espinoza A,Beeksma B,Petasecca M,Fuduli I,Porumb C,Cutajar D,Corde S,Jackson M,Lerch ML,Rosenfeld AB

    更新日期:2013-11-01 00:00:00

  • Image-based iterative compensation of motion artifacts in computed tomography.

    abstract:PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3244035

    authors: Schretter C,Rose G,Bertram M

    更新日期:2009-11-01 00:00:00

  • Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber.

    abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1709490

    authors: Hakanen AT,Sipilä PM,Kosunen A

    更新日期:2004-05-01 00:00:00

  • A deep feature fusion methodology for breast cancer diagnosis demonstrated on three imaging modality datasets.

    abstract:BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12453

    authors: Antropova N,Huynh BQ,Giger ML

    更新日期:2017-10-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008428

    authors: Zhao W,Li D,Reznik A,Lui BJ,Hunt DC,Rowlands JA,Ohkawa Y,Tanioka K

    更新日期:2005-09-01 00:00:00

  • Temporal and spectral imaging with micro-CT.

    abstract:PURPOSE:Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with du...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736809

    authors: Johnston SM,Johnson GA,Badea CT

    更新日期:2012-08-01 00:00:00

  • A data-mining framework for large scale analysis of dose-outcome relationships in a database of irradiated head and neck cancer patients.

    abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922686

    authors: Robertson SP,Quon H,Kiess AP,Moore JA,Yang W,Cheng Z,Afonso S,Allen M,Richardson M,Choflet A,Sharabi A,McNutt TR

    更新日期:2015-07-01 00:00:00

  • Evaluation of a compact multicontrast and multiresolution X-ray phase contrast edge illumination system for small animal imaging.

    abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14553

    authors: Massimi L,Meganck JA,Towns R,Olivo A,Endrizzi M

    更新日期:2020-10-27 00:00:00

  • Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578602

    authors: Su Z,Zhang L,Ramakrishnan V,Hagan M,Anscher M

    更新日期:2011-05-01 00:00:00

  • Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.

    abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13272

    authors: Shunhavanich P,Hsieh SS,Pelc NJ

    更新日期:2019-01-01 00:00:00

  • Comparison of two independent exposure measurement techniques for clinical I-125 seeds.

    abstract::This investigation contains the results of exposure measurements on two types of clinical I-125 seeds: a model 6702 no-marker seed, and a model 6711 silver wire seed. Measurements were made locally with a parallel-plate mammography chamber, traceable to the National Bureau of Standards (NBS) calibration. The same seed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595784

    authors: Kubo H

    更新日期:1985-03-01 00:00:00

  • Poster - Thur Eve - 64: Evaluation of SmartArc and RapidArc for lung SBRT treatment planning and delivery.

    abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740172

    authors: Fakir H,Hoover D,Chen JZ

    更新日期:2012-07-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • Benchmarking brachydose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.

    abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2400843

    authors: Taylor RE,Yegin G,Rogers DW

    更新日期:2007-02-01 00:00:00

  • Estimation of organ and effective dose due to Compton backscatter security scans.

    abstract:PURPOSE:To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. METHODS:Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4718680

    authors: Hoppe ME,Schmidt TG

    更新日期:2012-06-01 00:00:00