Abstract:
:Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure breast density were evaluated: the usage of monoenergetic beams and an ideal detector, and the usage of polyenergetic beams with spectra from a tungsten anode x-ray tube with a detector modeled after a digital mammography system. The simulation model calculated the mean glandular dose necessary to quantify the variability of breast density to within 1/3%. The breast was modeled as a semicircle 10 cm in radius with equal homogenous thicknesses of adipose and glandular tissues. Breast thicknesses were considered in the range of 2-10 cm and energies in the range of 10-150 keV for the two monoenergetic beams, and 20-150 kVp for spectra with a tungsten anode x-ray tube. For a 4.2 cm breast thickness, the required mean glandular doses were 0.183 microGy for two monoenergetic beams at 19 and 71 keV, and 9.85 microGy for two polyenergetic spectra from a tungsten anode at 32 and 96 kVp with beam filtrations of 50 microm Rh and 300 microm Cu for the low and high energy beams, respectively. The results suggest that for either configuration, breast density can be precisely measured with dual energy imaging requiring only a small amount of additional dose to the breast. The possibility of using a standard screening mammogram as the low energy image is also discussed.
journal_name
Med Physjournal_title
Medical physicsauthors
Ducote JL,Molloi Sdoi
10.1118/1.3002308subject
Has Abstractpub_date
2008-12-01 00:00:00pages
5411-8issue
12eissn
0094-2405issn
2473-4209journal_volume
35pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735200
更新日期:2012-06-01 00:00:00
abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2794175
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12459
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3641874
更新日期:2011-11-01 00:00:00
abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1344203
更新日期:2001-02-01 00:00:00
abstract:PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3260844
更新日期:2010-01-01 00:00:00
abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594403
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735217
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This study aims to investigate carotid plaque calcification (CPC) using two-dimensional (2D) and 3D ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences and compare T1, T2*, water concentration, and bone mineral density (BMD) of CPC with those of cortical bone. METHODS:Twelve carotid plaque sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819944
更新日期:2013-10-01 00:00:00
abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2739805
更新日期:2007-07-01 00:00:00
abstract::When a beam-modifying filter such as a wedge or a compensator is placed in an x-ray beam, scattered photons are generated in the filter material. The magnitude of the dose contribution from these photons for a 4-MV x-ray beam was measured. At a distance of 30 cm from the filter, a copper sheet of 1-cm thickness produc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595923
更新日期:1986-01-01 00:00:00
abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2804722
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948687
更新日期:2016-06-01 00:00:00
abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595546
更新日期:1984-09-01 00:00:00
abstract:PURPOSE:To quantify the inter fraction variation of spatial location of high dose regions of OARs in MR-image based cervix brachytherapy using rigid registration algorithm. METHODS:Retrospective analysis of 27 previously treated patients under EMBRACE multi-centric trial was evaluated. Each patient had two application...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735513
更新日期:2012-06-01 00:00:00
abstract::The BEAMnrc/EGSnrc Monte Carlo code system is employed to develop a model of the National Research Council of Canada primary standard of absorbed dose to tissue in a beta radiation field, comprising an extrapolation chamber and 90Sr/90Y beta source. We benchmark the model against the measured response of the chamber i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1997347
更新日期:2005-10-01 00:00:00
abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595794
更新日期:1985-01-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594310
更新日期:1977-03-01 00:00:00
abstract::We have measured the linearity, spatial resolution (MTF), noise (NPS), and signal-to-noise characteristics (DQE) of an electronic portal imaging device (EPID) based on an amorphous silicon flat-panel array. The array has a 128 x 128-pixel matrix and each pixel is 0.75 x 0.75 mm2 in dimension so the array covers an are...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598252
更新日期:1998-05-01 00:00:00
abstract:PURPOSE:Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum est...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3676740
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4864474
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:The authors describe a design for prepatient region of interest attenuators (ROIAs) to reduce dose area product (DAP) for clinical use. The authors describe a model to predict DAP values from x-ray technique parameters recorded during a clinical procedure for image sequences obtained in the presence or absence ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903898
更新日期:2015-01-01 00:00:00
abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2790586
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734756
更新日期:2012-06-01 00:00:00
abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2103447
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper des...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794495
更新日期:2013-04-01 00:00:00
abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1315317
更新日期:2000-11-01 00:00:00
abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2996288
更新日期:2008-11-01 00:00:00