Abstract:
PURPOSE:Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper describes an extension of the CSA approach to incorporate coherent and incoherent interactions, important for low-Z detectors such as silicon and selenium. METHODS:A parallel-cascade approach is used to describe the three types of x-ray interactions. The description of incoherent scatter required developing expressions for signal and noise transfer through an "energy-labeled reabsorption" process where the parameters describing reabsorption are random functions of the scatter photon energy. The description of coherent scatter requires the use of scatter form factors that may not be accurate for some crystalline detector materials. The model includes the effects of scatter reabsorption and escape, charge collection, secondary quantum sinks, noise aliasing, and additive noise. Model results are validated by Monte Carlo calculations for Si and Se detectors assuming free-atom atomic form factors. RESULTS:The new signal and noise transfer expressions were validated by showing agreement with Monte Carlo results. Coherent and incoherent scatter can degrade the DQE of Si and sometimes Se detectors depending on detector thickness and incident-photon energy. Incoherent scatter can produce a substantial low-frequency drop in the modulation transfer function and DQE. CONCLUSIONS:A generally useful CSA model of the DQE is described that is believed valid for any single-Z material up to 10 cycles/mm at both mammographic and radiographic energies within the limitations of Fourier-based linear-systems models and the use of coherent-scatter form factors. The model describes a substantial low-frequency drop in the DQE of Si systems due to incoherent scatter above 20-40 keV.
journal_name
Med Physjournal_title
Medical physicsauthors
Yun S,Tanguay J,Kim HK,Cunningham IAdoi
10.1118/1.4794495subject
Has Abstractpub_date
2013-04-01 00:00:00pages
041916issue
4eissn
0094-2405issn
2473-4209journal_volume
40pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. METHODS:A 100 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3476459
更新日期:2010-09-01 00:00:00
abstract::Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598615
更新日期:1999-07-01 00:00:00
abstract:PURPOSE:To investigate the critical structure sparing achievable by biological optimization for modulated volumetric arc (VMAT) of head and neck (H&N) cancer. METHODS:Ten H&N VMAT patients who were originally planned and treated with simultaneous integrated boost technique using dose-volume based optimization, were se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735671
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13517
更新日期:2019-06-01 00:00:00
abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595407
更新日期:1983-09-01 00:00:00
abstract:PURPOSE:It is important to enhance image quality for low-dose CT acquisitions to push the ALARA boundary. Current state-of-the-art block-matching three-dimensional (BM3D) denoising scheme assumes white Gaussian noise (WGN) model. This study proposes a novel filtering module to be incorporated into the BM3D framework fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13252
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. METHODS:Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4729738
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894817
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14208
更新日期:2020-08-01 00:00:00
abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596296
更新日期:1988-07-01 00:00:00
abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3081414
更新日期:2009-04-01 00:00:00
abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.3002314
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914863
更新日期:2015-05-01 00:00:00
abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596063
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905104
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14557
更新日期:2020-10-28 00:00:00
abstract:PURPOSE:Potential collision between the patient∕couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760988
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). METHODS:Seventy-five kilovoltage cone beam CTs (KV-CBCT) from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803499
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928148
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4722746
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14580
更新日期:2020-11-05 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14696
更新日期:2020-12-31 00:00:00
abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12554
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications wh...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4729837
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914398
更新日期:2015-04-01 00:00:00
abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594310
更新日期:1977-03-01 00:00:00
abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734794
更新日期:2012-06-01 00:00:00