Abstract:
:We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have been derived for calculating the area and the uncertainty. Assuming that the underlying ellipse has limited ellipticity (major/minor axis ratio less than five), it is shown that the average uncertainty in the area is less than 14%. When more than two views are available, we suggest using a least-squares fit method to extract all available information from the data.
journal_name
Med Physjournal_title
Medical physicsauthors
Lee PL,Selzer RHdoi
10.1118/1.596296subject
Has Abstractpub_date
1988-07-01 00:00:00pages
576-80issue
4eissn
0094-2405issn
2473-4209journal_volume
15pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13763
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928148
更新日期:2015-09-01 00:00:00
abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2731034
更新日期:2007-06-01 00:00:00
abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595834
更新日期:1986-09-01 00:00:00
abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597170
更新日期:1994-04-01 00:00:00
abstract::Total body photon irradiation (TBI) may be delivered with a number of standard techniques, typically using extended SSD geometries to obtain large field sizes. Since 1982 we have treated over 620 patients (adult and pediatric) mostly in the floor-located prone/supine treatment position with AP/PA beams using a column ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740139
更新日期:2012-07-01 00:00:00
abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595218
更新日期:1982-01-01 00:00:00
abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1289375
更新日期:2000-09-01 00:00:00
abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595582
更新日期:1984-11-01 00:00:00
abstract:PURPOSE:The appearance of parenchymal∕stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736422
更新日期:2012-08-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740172
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4955121
更新日期:2016-08-01 00:00:00
abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2779862
更新日期:2007-10-01 00:00:00
abstract::The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598167
更新日期:1998-01-01 00:00:00
abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3656025
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963213
更新日期:2016-10-01 00:00:00
abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1800712
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222732
更新日期:2009-10-01 00:00:00
abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594392
更新日期:1977-05-01 00:00:00
abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3250907
更新日期:2009-12-01 00:00:00
abstract:PURPOSE:Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964456
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734756
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide (R) and implant duration (T). This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position (P), prescription dose, R, an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735548
更新日期:2012-06-01 00:00:00
abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1381549
更新日期:2001-07-01 00:00:00
abstract::System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598072
更新日期:1997-02-01 00:00:00
abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906129
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Given its sensitivity to anatomical variations, proton therapy is expected to benefit greatly from integration with magnetic resonance imaging for online anatomy monitoring during irradiation. Such an integration raises several challenges, as both systems mutually interact. The proton beam will experience quasi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12961
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13287
更新日期:2019-01-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426000
更新日期:2010-08-01 00:00:00