Abstract:
PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the original MAGIC formulation to adjust the O/C ratio. The dose responses of the new formulations were tested with MRI transverse relaxation rate (R2) measurements. RESULTS:The new ingredients improved not only the elemental composition but also the sensitivity of the MAGIC gel. The O/C ratios of our new gels agree with that of soft tissue within 1%. The slopes of dose response curves were 1.6-2.7 times larger with glucose. The melting point also increased by 5 degrees C. Further addition of urea resulted in a similar slope but with an increased intercept and a decreased melting point. CONCLUSIONS:Our improved MAGIC gel formulations have higher sensitivity and better elemental tissue equivalency for 3D dosimetry applications involving nuclear reactions.
journal_name
Med Physjournal_title
Medical physicsauthors
Zhu X,Reese TG,Crowley EM,El Fakhri Gdoi
10.1118/1.3260844subject
Has Abstractpub_date
2010-01-01 00:00:00pages
183-8issue
1eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Scattered radiation remains to be a major cause of image quality degradation in Flat Panel Detector (FPD)-based Cone-beam computed tomography (CBCT). We have been investigating a novel two-dimensional antiscatter grid (2D-ASG) concept to reduce scatter intensity, and hence improve CBCT image quality. We present...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12724
更新日期:2018-02-01 00:00:00
abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596309
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:To quantify the inter fraction variation of spatial location of high dose regions of OARs in MR-image based cervix brachytherapy using rigid registration algorithm. METHODS:Retrospective analysis of 27 previously treated patients under EMBRACE multi-centric trial was evaluated. Each patient had two application...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735513
更新日期:2012-06-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4859295
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4953831
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773866
更新日期:2013-02-01 00:00:00
abstract::Diode sensitivity variations with temperature (SVWT) have been reported to vary from small negative values up to 0.6% per degrees C. Thus it is possible for diode calibration factors established at room temperature (approximately 20 degrees C) to yield errors in the range of -1% to +9% when diodes are placed on a pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367862
更新日期:2001-05-01 00:00:00
abstract:PURPOSE:In the context of fluorescence diffuse optical tomography, determining the optimal way to exploit the time-resolved information has been receiving much attention and different features of the time-resolved signals have been introduced. In this article, the authors revisit and generalize the notion of feature, c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431571
更新日期:2010-06-01 00:00:00
abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1852791
更新日期:2005-02-01 00:00:00
abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952359
更新日期:2008-08-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3063544
更新日期:2009-02-01 00:00:00
abstract::The Gafchromic EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2362876
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3137572
更新日期:2009-06-01 00:00:00
abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508110
更新日期:2002-10-01 00:00:00
abstract::Stereotactic Body Radiation Therapy (SBRT) is being increasingly used in the radiation oncology community to treat tumors in extra-cranial sites such as spine, lung, liver, pancreas and prostate. There are well established RTOG protocols (e.g. RTOG 0631 for spine, RTOG 0813 and 0915 for lung and RTOG 0438 for liver) t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736142
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4944501
更新日期:2016-04-01 00:00:00
abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2912178
更新日期:2008-06-01 00:00:00
abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1617550
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930798
更新日期:2015-10-01 00:00:00
abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2719363
更新日期:2007-05-01 00:00:00
abstract::The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3017470
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:This article introduces the use of low power continuous wave frequency modulated radar for medical applications, specifically for remote monitoring of vital signs in patients. METHODS:Gigahertz frequency radar measures the electromagnetic wave signal reflected from the surface of a human body and from tissue b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3267038
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735153
更新日期:2012-06-01 00:00:00
abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598459
更新日期:1998-12-01 00:00:00
abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3355933
更新日期:2010-04-01 00:00:00
abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598219
更新日期:1998-04-01 00:00:00
abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3641874
更新日期:2011-11-01 00:00:00