Abstract:
:Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is difficult, however, because their emission energies are close. The authors previously developed a fast Monte Carlo (MC)-based joint ordered-subset expectation maximization (JOSEM) iterative reconstruction algorithm (MC-JOSEM), which simultaneously compensates for scatter and cross talk as well as detector response within the reconstruction algorithm. In this work, the authors evaluated the performance of MC-JOSEM in a realistic population of 99mTc/123I studies using cardiac phantom data on a Siemens e.cam system using a standard cardiac protocol. The authors also compared the performance of MC-JOSEM for estimation tasks to that of two other methods: standard OSEM using photopeak energy windows without scatter correction (NSC-OSEM) and standard OSEM using a Compton-scatter energy window for scatter correction (SC-OSEM). For each radionuclide the authors separately acquired high-count projections of radioactivity in the myocardium wall, liver, and soft tissue background compartments of a water-filled torso phantom, and they generated synthetic projections of various dual-radionuclide activity distributions. Images of different combinations of myocardium wall/background activity concentration ratios for each radionuclide were reconstructed by NSC-OSEM, SC-OSEM, and MC-JOSEM. For activity estimation in the myocardium wall, MC-JOSEM always produced the best relative bias and relative standard deviation compared with NSC-OSEM and SC-OSEM for all the activity combinations. On average, the relative biases after 100 iterations were 8.1% for 99mTc and 3.7% for 123I with MC-JOSEM, 39.4% for 99mTc and 23.7% for 123I with NSC-OSEM, and 20.9% for 99mTc with SC-OSEM. The relative standard deviations after 30 iterations were 0.7% for 99mTc and 1.0% for 123I with MC-JOSEM, as compared to 1.1% for 99mTc and 1.2% for 123I with NSC-OSEM and 1.3% for 99mTc with SC-OSEM. Finally, the authors compared the relative standard deviation after 30 iterations with the minimum theoretical variance on activity estimation, the Cramer-Rao lower bound (CRB), and with the biased CRB. The measured precision was larger than the biased bound values by factors of 2-4, suggesting that further improvement could be made to the method.
journal_name
Med Physjournal_title
Medical physicsauthors
Ouyang J,Zhu X,Trott CM,El Fakhri Gdoi
10.1118/1.3063544subject
Has Abstractpub_date
2009-02-01 00:00:00pages
602-11issue
2eissn
0094-2405issn
2473-4209journal_volume
36pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1445411
更新日期:2002-02-01 00:00:00
abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664006
更新日期:2012-01-01 00:00:00
abstract::In nuclear magnetic resonance (NMR) imaging by the zeugmatographic methods, there is a common and unified theoretical description. All forms of two-dimensional and three-dimensional imaging involve NMR data which trace various geometric representations, in reciprocal transform space, of the subject's spatially blurred...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595470
更新日期:1984-01-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597041
更新日期:1993-03-01 00:00:00
abstract::This paper investigates the effect of the waterproofing sleeve on the calibration of kilovoltage photon beams (50-300 kV). The sleeve effect correction factor, ps has been calculated using the Monte Carlo method as the ratios of the air kerma in an air cavity of a cylindrical chamber without the waterproofing sleeve t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598039
更新日期:1997-09-01 00:00:00
abstract::Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1493216
更新日期:2002-08-01 00:00:00
abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595878
更新日期:1986-05-01 00:00:00
abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598979
更新日期:2000-05-01 00:00:00
abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3148834
更新日期:2009-07-01 00:00:00
abstract::New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2897966
更新日期:2008-05-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2786864
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of skin dose determination for composite multibeam 3D conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) treatments using optically stimulated luminescent dosimeters (OSLDs) and Eclipse treatment planning system. METHODS:Surface doses measured by OSLDs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4890795
更新日期:2014-08-01 00:00:00
abstract:PURPOSE:The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. METHODS:Balanced data according to the one-factor random effect model were assumed. RESULTS:Analysis-of-variance (anova)-based computation was ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4961397
更新日期:2016-09-01 00:00:00
abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712042
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868693
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14130
更新日期:2020-07-01 00:00:00
abstract::The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2750966
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3481507
更新日期:2010-09-01 00:00:00
abstract::The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inh...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595739
更新日期:1985-01-01 00:00:00
abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752083
更新日期:2012-10-01 00:00:00
abstract::Spectra, yields, average energies, and kerma rates in tissue of neutrons from 21-MeV deuteron bombardment of deuterium gas targets have been calculated for target thicknesses of 1, 3.5, and 5 MeV. A high pressure gas cell was constructed and was filled with 33 atm of D2 gas (equivalent to an energy loss of 3.5 MeV for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594561
更新日期:1979-05-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3442276
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13073
更新日期:2018-06-29 00:00:00
abstract:PURPOSE:Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3213092
更新日期:2009-10-01 00:00:00
abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598804
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4811238
更新日期:2013-07-01 00:00:00