Fast time-of-flight camera based surface registration for radiotherapy patient positioning.

Abstract:

PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an "ICP only" strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. RESULTS:The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07° ± 0.05°, respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. CONCLUSIONS:The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the usage of a cost-effective off-the-shelf technology for surface acquisition. Further strategies to improve the registration accuracy are under development.

journal_name

Med Phys

journal_title

Medical physics

authors

Placht S,Stancanello J,Schaller C,Balda M,Angelopoulou E

doi

10.1118/1.3664006

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

4-17

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • In vivo functional chronic imaging of a small animal model using optical-resolution photoacoustic microscopy.

    abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3137572

    authors: Hu S,Maslov K,Wang LV

    更新日期:2009-06-01 00:00:00

  • SU-E-T-142: Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams.

    abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735200

    authors: Inoue T,Sugimoto S,Fukata K,Kurokawa C,Ozawa S,Sasai K

    更新日期:2012-06-01 00:00:00

  • Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

    abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3063544

    authors: Ouyang J,Zhu X,Trott CM,El Fakhri G

    更新日期:2009-02-01 00:00:00

  • Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    abstract::An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008428

    authors: Zhao W,Li D,Reznik A,Lui BJ,Hunt DC,Rowlands JA,Ohkawa Y,Tanioka K

    更新日期:2005-09-01 00:00:00

  • Contamination dose from photoneutron processes in bodily tissues during therapeutic radiation delivery.

    abstract::Dose to the total body from induced radiation resulting from primary exposure to radiotherapeutic beams is not detailed in routine treatment planning though this information is potentially important for better estimates of health risks including secondary cancers. This information can also allow better management of p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1612947

    authors: Difilippo F,Papiez L,Moskvin V,Peplow D,DesRosiers C,Johnson J,Timmerman R,Randall M,Lillie R

    更新日期:2003-10-01 00:00:00

  • Assessment of the spectral performance of hybrid photon counting x-ray detectors.

    abstract:PURPOSE:Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12323

    authors: Trueb P,Zambon P,Broennimann C

    更新日期:2017-09-01 00:00:00

  • Scattered radiation in chest radiography.

    abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595027

    authors: Niklason LT,Sorenson JA,Nelson JA

    更新日期:1981-09-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams.

    abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14054

    authors: Ito S,Araki F,Ohno T

    更新日期:2020-04-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

    abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2147744

    authors: Wendling M,Louwe RJ,McDermott LN,Sonke JJ,van Herk M,Mijnheer BJ

    更新日期:2006-02-01 00:00:00

  • Quantum noise in detectors.

    abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595393

    authors: Rimkus D,Baily NA

    更新日期:1983-07-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • A statistical approach to infer the minimum setup distance of a well chamber to the wall or to the floor for 192Ir HDR calibration.

    abstract::We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of 192Ir high dose rate (HDR). The chamber should be placed at least this distance away from any wall or from the floor in order to mitigate the effect of scatter. Three dif...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2911156

    authors: Chang L,Ho SY,Chui CS,Lee JH,Du YC,Chen T

    更新日期:2008-06-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • Fast contour propagation for MR-guided prostate radiotherapy using convolutional neural networks.

    abstract:PURPOSE:To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS:Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13994

    authors: Eppenhof KAJ,Maspero M,Savenije MHF,de Boer JCJ,van der Voort van Zyp JRN,Raaymakers BW,Raaijmakers AJE,Veta M,van den Berg CAT,Pluim JPW

    更新日期:2020-03-01 00:00:00

  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00

  • Dose distributions around cylindrical 241Am sources for a clinical intracavitary applicator.

    abstract::Encapsulated, cylindrical sources containing 2, 5, and 8 Ci of 241Am have been designed and fabricated for intracavitary irradiation of uterine cancers. Exposure rates in air and dose rates in water around these sources have been measured using an ionization chamber and a lithium fluoride thermoluminescent dosimetry s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596007

    authors: Nath R,Gray L,Park CH

    更新日期:1987-09-01 00:00:00

  • Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging.

    abstract:PURPOSE:Radiotherapy is an effective treatment for many types of cancer in clinical settings. Gel dosimetry has the potential to record three-dimensional (3D) dose distribution compared to a conventional ion chamber. As the elasticity of the gel is altered after irradiation due to gel polymerization, we aim to measure ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14020

    authors: Xie WH,Su CT,Kao YJ,Chang TH,Chang YJ,Yao CH,Hsieh BY

    更新日期:2020-03-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • Motion tracking in the liver: validation of a method based on 4D ultrasound using a nonrigid registration technique.

    abstract:PURPOSE:Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4890091

    authors: Vijayan S,Klein S,Hofstad EF,Lindseth F,Ystgaard B,Langø T

    更新日期:2014-08-01 00:00:00

  • SU-E-T-302: A Simulation Study with Geant4 Investigating the Secondary Prompt Gamma Emissions from Incident 40 MeV Protons Onto Various Materials.

    abstract:PURPOSE:This study aims to investigate the prompt secondary gamma spectrum and thedepth-dose distributions of incident 40 MeV protons onto various phantom materials.The goal is to find a relationship between the secondary prompt gamma emissions andthe range of the incident particles. METHODS:An application was constru...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735388

    authors: Lau A,Chen Y,Ahmad S

    更新日期:2012-06-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • Principles in positioning cross-projecting lasers.

    abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594960

    authors: Thomadsen BR

    更新日期:1981-05-01 00:00:00

  • Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.

    abstract:PURPOSE:When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14139

    authors: Geoghegan TJ,Nelson NP,Flynn RT,Hill PM,Rana S,Hyer DE

    更新日期:2020-07-01 00:00:00

  • Computation of energy imparted in diagnostic radiology.

    abstract::Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597939

    authors: Gkanatsios NA,Huda W

    更新日期:1997-04-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • Technical Note: Comparison of megavoltage, dual-energy, and single-energy CT-based μ-maps for a four-channel breast coil in PET/MRI.

    abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12407

    authors: Patrick JC,Terry Thompson R,So A,Butler J,Faul D,Stodilka RZ,Yartsev S,Prato FS,Gaede S

    更新日期:2017-09-01 00:00:00