Abstract:
:A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of 50 microm. Two devices were evaluated with differing crystalline quality. Incomplete charge collection was a source of reduction in DQE. This occurs in both devices due to characteristically low mobility-lifetime products for CdZnTe, with the greatest losses demonstrated by the multicrystalline sample. The mobility-lifetime products for the multicrystalline device were found to be 2.4 x 10(-4) and 4.0 x 10(-7) cm2/V for electrons and holes, respectively. The device constructed with higher quality single crystal CdZnTe demonstrated mobility-lifetime products of 1.0 x 10(-4) and 4.4 x 10(-6) cm2/V for electrons and holes. The MTF and DQE for the device were measured at several exposures and results were compared to predictions from a linear systems model of signal and noise propagation. The MTF at a spatial frequency of 10 mm(-1) exceeded 0.18 and 0.56 along the scan and slot directions, respectively. Scanning motion and CCD design limited the resolution along the scan direction. For an x-ray beam from a tungsten target tube with 40 microm molybdenum filtration operated at 26 kV, the single crystal device demonstrated a DQE(0) of 0.70 +/- 0.02 at 7.1 x 10(-6) C/kg (27 mR) exposure to the detector, despite its relatively poor charge collection efficiency.
journal_name
Med Physjournal_title
Medical physicsauthors
Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJdoi
10.1118/1.1523932subject
Has Abstractpub_date
2002-12-01 00:00:00pages
2767-81issue
12eissn
0094-2405issn
2473-4209journal_volume
29pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Anatomical variations occur during head and neck (H&N) radiotherapy treatment. kV cone-beam computed tomography (CBCT) images can be used for daily dose monitoring to assess dose variations owing to anatomic changes. Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) from CBCT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14387
更新日期:2020-10-01 00:00:00
abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596971
更新日期:1993-07-01 00:00:00
abstract::The physical factors that govern 2D and 3D imaging performance may be understood from quantitative analysis of the spatial-frequency-dependent signal and noise transfer characteristics [e.g., modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002414
更新日期:2008-12-01 00:00:00
abstract::System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598072
更新日期:1997-02-01 00:00:00
abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598259
更新日期:1998-05-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract::Postoperative beta-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that beta-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure beta-irradiation using a 90Sr/Y applicator has...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2896076
更新日期:2008-05-01 00:00:00
abstract:PURPOSE:Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Car...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12413
更新日期:2017-09-01 00:00:00
abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595807
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13807
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:For almost four decades bead and wire ramps have been used in the evaluation of slice width as part of QA testing for CT scanners. While each of these approaches have been recognized and accepted as reliable, in this paper we investigate the differences, advantages and limitations of these tools. Moreover, we s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734753
更新日期:2012-06-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596192
更新日期:1988-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12407
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:Colon cancer is a major public health problem due to its high disease rate and death toll worldwide. The use of FTIR microscopy in the field of cancer diagnosis has become attractive over the past 20 years. In the present study, the authors investigated the potential of FTIR microscopy to define spectral change...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298013
更新日期:2010-03-01 00:00:00
abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598306
更新日期:1998-07-01 00:00:00
abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679856
更新日期:2012-02-01 00:00:00
abstract::Adaptive histogram equalization techniques are known to be effective for the enhancement of contrast in portal images acquired during radiotherapy treatments. A significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it can be remedied by separating the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596807
更新日期:1992-05-01 00:00:00
abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2739805
更新日期:2007-07-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13002
更新日期:2018-05-28 00:00:00
abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735656
更新日期:2012-06-01 00:00:00
abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740105
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734668
更新日期:2012-06-01 00:00:00
abstract::Part III (oral exam) is the final part of ABR board exam for Diagnostic Medical Physics. In this exam, each of five oral examiners questions the candidate in each of five question categories. Oral exam has unique challenges to the candidate compared with the written exams. The candidate is expected to have not only ad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736136
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Intraoperative electron radiation therapy (IOERT) involves the delivery of a high radiation dose during tumor resection in a shorter time than other radiation techniques, thus improving local control of tumors. However, a linear accelerator device is needed to produce the beam safely. Mobile linear accelerators...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12482
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736420
更新日期:2012-08-01 00:00:00
abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868757
更新日期:2008-04-01 00:00:00
abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595794
更新日期:1985-01-01 00:00:00
abstract::We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1359245
更新日期:2001-04-01 00:00:00