Fast contour propagation for MR-guided prostate radiotherapy using convolutional neural networks.

Abstract:

PURPOSE:To quickly and automatically propagate organ contours from pretreatment to fraction images in magnetic resonance (MR)-guided prostate external-beam radiotherapy. METHODS:Five prostate cancer patients underwent 20 fractions of image-guided external-beam radiotherapy on a 1.5 T MR-Linac system. For each patient, a pretreatment T2-weighted three-dimensional (3D) MR imaging (MRI) scan was used to delineate the clinical target volume (CTV) contours. The same scan was repeated during each fraction, with the CTV contour being manually adapted if necessary. A convolutional neural network (CNN) was trained for combined image registration and contour propagation. The network estimated the propagated contour and a deformation field between the two input images. The training set consisted of a synthetically generated ground truth of randomly deformed images and prostate segmentations. We performed a leave-one-out cross-validation on the five patients and propagated the prostate segmentations from the pretreatment to the fraction scans. Three variants of the CNN, aimed at investigating supervision based on optimizing segmentation overlap, optimizing the registration, and a combination of the two were compared to results of the open-source deformable registration software package Elastix. RESULTS:The neural networks trained on segmentation overlap or the combined objective achieved significantly better Hausdorff distances between predicted and ground truth contours than Elastix, at the much faster registration speed of 0.5 s. The CNN variant trained to optimize both the prostate overlap and deformation field, and the variant trained to only maximize the prostate overlap, produced the best propagation results. CONCLUSIONS:A CNN trained on maximizing prostate overlap and minimizing registration errors provides a fast and accurate method for deformable contour propagation for prostate MR-guided radiotherapy.

journal_name

Med Phys

journal_title

Medical physics

authors

Eppenhof KAJ,Maspero M,Savenije MHF,de Boer JCJ,van der Voort van Zyp JRN,Raaymakers BW,Raaijmakers AJE,Veta M,van den Berg CAT,Pluim JPW

doi

10.1002/mp.13994

subject

Has Abstract

pub_date

2020-03-01 00:00:00

pages

1238-1248

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • "SABER": A new software tool for radiotherapy treatment plan evaluation.

    abstract:PURPOSE:Both spatial and biological information are necessary in order to perform true optimization of a treatment plan and for predicting clinical outcome. The goal of this work is to develop an enhanced treatment plan evaluation tool which incorporates biological parameters and retains spatial dose information. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3497152

    authors: Zhao B,Joiner MC,Orton CG,Burmeister J

    更新日期:2010-11-01 00:00:00

  • A sparse representation-based radiomics for outcome prediction of higher grade gliomas.

    abstract:PURPOSE:Accurately predicting outcome (i.e., overall survival (OS) time) for higher grade glioma (HGG) has great clinical value and would provide optimized guidelines for treatment planning. Radiomics focuses on revealing underlying pathophysiological information in biomedical images for disease analysis and demonstrat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13288

    authors: Wu G,Shi Z,Chen Y,Wang Y,Yu J,Lv X,Chen L,Ju X,Chen Z

    更新日期:2019-01-01 00:00:00

  • Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters.

    abstract:PURPOSE:To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4803466

    authors: Giaddui T,Cui Y,Galvin J,Yu Y,Xiao Y

    更新日期:2013-06-01 00:00:00

  • Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4719962

    authors: Lundh O,Rechatin C,Faure J,Ben-Ismaïl A,Lim J,De Wagter C,De Neve W,Malka V

    更新日期:2012-06-01 00:00:00

  • Sensitivity of amorphous selenium to x rays from 40 kVp to 18 MV: measurements and implications for portal imaging.

    abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598219

    authors: Mah D,Rowlands JA,Rawlinson JA

    更新日期:1998-04-01 00:00:00

  • Dosimetric characterization of Ir-192 LDR elongated sources.

    abstract::Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2839102

    authors: van der Laarse R,Granero D,Pérez-Calatayud J,Meigooni AS,Ballester F

    更新日期:2008-03-01 00:00:00

  • Transverse axial film tomography with a therapy simulator.

    abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594662

    authors: Kessaris ND,Harisiadis L

    更新日期:1980-03-01 00:00:00

  • Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach.

    abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4739195

    authors: Fredenberg E,Danielsson M,Stayman JW,Siewerdsen JH,Aslund M

    更新日期:2012-09-01 00:00:00

  • Quantum noise in detectors.

    abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595393

    authors: Rimkus D,Baily NA

    更新日期:1983-07-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Volumetric breast density evaluation from ultrasound tomography images.

    abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2964092

    authors: Glide-Hurst CK,Duric N,Littrup P

    更新日期:2008-09-01 00:00:00

  • The effect of dose calculation uncertainty on the evaluation of radiotherapy plans.

    abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598916

    authors: Keall PJ,Siebers JV,Jeraj R,Mohan R

    更新日期:2000-03-01 00:00:00

  • Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

    abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736420

    authors: Gang GJ,Zbijewski W,Webster Stayman J,Siewerdsen JH

    更新日期:2012-08-01 00:00:00

  • TU-G-BRB-01: Continuous Path Optimization for Non-Coplanar Variant SAD IMRT Delivery Using C-Arm Machines.

    abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735996

    authors: Ruan D,Dong P,Low D,Sheng K

    更新日期:2012-06-01 00:00:00

  • Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties.

    abstract:PURPOSE:Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. METHODS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4852875

    authors: Tadayyon H,Sadeghi-Naini A,Wirtzfeld L,Wright FC,Czarnota G

    更新日期:2014-01-01 00:00:00

  • Potential of in vivo MRI-based nonlinear finite-element analysis for the assessment of trabecular bone post-yield properties.

    abstract:PURPOSE:Bone strength is the key factor impacting fracture risk. Assessment of bone strength from high-resolution (HR) images have largely relied on linear micro-finite element analysis (μFEA) even though failure always occurs beyond the yield point, which is outside the linear regime. Nonlinear μFEA may therefore be m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4802085

    authors: Zhang N,Magland JF,Rajapakse CS,Bhagat YA,Wehrli FW

    更新日期:2013-05-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Dose buildup for obliquely incident photon beams.

    abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596055

    authors: Gerbi BJ,Meigooni AS,Khan FM

    更新日期:1987-05-01 00:00:00

  • Comparative assessment of linear least-squares, nonlinear least-squares, and Patlak graphical method for regional and local quantitative tracer kinetic modeling in cerebral dynamic 18 F-FDG PET.

    abstract:PURPOSE:Dynamic 18 F-FDG PET allows quantitative estimation of cerebral glucose metabolism both at the regional and local (voxel) level. Although sensitive to noise and highly computationally expensive, nonlinear least-squares (NLS) optimization stands as the reference approach for the estimation of the kinetic model p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13366

    authors: Ben Bouallègue F,Vauchot F,Mariano-Goulart D

    更新日期:2019-03-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00

  • Technical Note: A proposal of air ventilation system design criteria for a clinical room in a heavy-ion medical facility.

    abstract:PURPOSE:An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. METHODS:Optimized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12914

    authors: Kum O

    更新日期:2018-06-01 00:00:00

  • Monte Carlo dosimetry for I125 and Pd103 eye plaque brachytherapy.

    abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002412

    authors: Thomson RM,Taylor REP,Rogers DWO

    更新日期:2008-12-01 00:00:00

  • Monte Carlo simulations on the water-to-air stopping power ratio for carbon ion dosimetry.

    abstract::Many papers discussed the I value for water given by the ICRU, concluding that a value of about 80 +/- 2 eV instead of 67.2 eV would reproduce measured ion depth-dose curves. A change in the I value for water would have an effect on the stopping power and, hence, on the water-to-air stopping power ratio, which is impo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3085877

    authors: Henkner K,Bassler N,Sobolevsky N,Jäkel O

    更新日期:2009-04-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • An accurate method for direct dual-energy calibration and decomposition.

    abstract::We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596512

    authors: Cardinal HN,Fenster A

    更新日期:1990-05-01 00:00:00

  • Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.

    abstract:PURPOSE:The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. METHODS:The device used in this study was Octavius 1000 SRS model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870439

    authors: Markovic M,Stathakis S,Mavroidis P,Jurkovic IA,Papanikolaou N

    更新日期:2014-05-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery.

    abstract::In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, whil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1751252

    authors: Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Colombo F,Perini S

    更新日期:2004-06-01 00:00:00

  • Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions.

    abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14116

    authors: Shono N,Ninni B,King F,Kato T,Tokuda J,Fujimoto T,Tuncali K,Hata N

    更新日期:2020-06-01 00:00:00