Abstract:
:Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as small as 200 and 50 microm, respectively. We used quantitative experimental and modeling techniques to investigate the optimal pixel size for imaging stents. Image quality was evaluated by the ability of subjects to perform two tasks: detect the presence of a stent and discriminate a partially deployed stent from a fully deployed one in synthetic images. With measurements at 50, 100, 200, and 300 microm, the 100 microm pixel size gave the maximum contrast sensitivity for the detection experiment with the idealized direct detector. For an idealized indirect detector with a scintillating layer, an optimal pixel size was obtained at 200 microm pixel size. A channelized human observer model predicted a peak at 150 and 170 microm, for the idealized direct and indirect detectors, respectively. With regard to the stent deployment task for both detector types, smaller pixel sizes are favored and there is a steep drop in performance with larger pixels. In general, with the increasing exposures, the model and measurements give the enhanced contrast sensitivities and a smaller optimal pixel size. The effects of electronic noise and fill factor were investigated using the model. We believe that the experimental results and human observer model predications can help guide the flat-panel detector design. In addition, the human observer model should work on the similar images and be applicable to the future model and actual flat-panel implementations.
journal_name
Med Physjournal_title
Medical physicsauthors
Jiang Y,Wilson DLdoi
10.1118/1.2169907subject
Has Abstractpub_date
2006-03-01 00:00:00pages
668-78issue
3eissn
0094-2405issn
2473-4209journal_volume
33pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539623
更新日期:2011-02-01 00:00:00
abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2044427
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:Periprocedural assessment of tissue perfusion by imaging methods could improve outcome control during treatment of peripheral vascular disease. Currently, endovascular revascularization treatments are assessed by planar angiography which only allows for qualitative inspection of blood flow in vessels. In this p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679864
更新日期:2012-03-01 00:00:00
abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288397
更新日期:2000-12-01 00:00:00
abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002308
更新日期:2008-12-01 00:00:00
abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1388219
更新日期:2001-08-01 00:00:00
abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12615
更新日期:2017-12-01 00:00:00
abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1709490
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Atherosclerosis of peripheral cerebral arteries can lead to stroke either by stenosis formation or plaque rupture. This pathology is initiated by the alteration of arterial wall mechanical properties shown to be assessable by ultrasound elastography. Recently, noninvasive vascular elastography (NIVE) was introd...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3539701
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735033
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3515458
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4772075
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735294
更新日期:2012-06-01 00:00:00
abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2134958
更新日期:2005-12-01 00:00:00
abstract::Current MRI nonuniformity correction techniques are reviewed and investigated. Many approaches are used to remedy this artifact, but it is not clear which method is the most appropriate in a given situation, as the applications have been with different MRI coils and different clinical applications. In this work four w...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.598357
更新日期:1998-09-01 00:00:00
abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595393
更新日期:1983-07-01 00:00:00
abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1844432
更新日期:2005-02-01 00:00:00
abstract:PURPOSE:In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 3...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3684952
更新日期:2012-03-01 00:00:00
abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597307
更新日期:1994-03-01 00:00:00
abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948999
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12795
更新日期:2018-04-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14433
更新日期:2020-10-01 00:00:00
abstract::The large variation of x-ray fluence at the detector in cone-beam CT (CBCT) poses a significant challenge to detectors' limited dynamic range, resulting in the loss of skinline as well as reduction of CT number accuracy, contrast-to-noise ratio, and image uniformity. The authors investigate the performance of a bowtie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3017470
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12627
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14580
更新日期:2020-11-05 00:00:00
abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792462
更新日期:2013-03-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00