Abstract:
:In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to correlate tumor position with external surrogate markers while simultaneously predicting the motion ahead in time, for situations in which neither the breathing pattern nor the correlation between moving anatomical elements is constant in time. One pancreatic cancer patient and two lung cancer patients with mid/upper lobe tumors were fluoroscopically imaged to observe tumor motion synchronously with the movement of external chest markers during free breathing. The external marker position was provided as input to a feed-forward neural network that correlated the marker and tumor movement to predict the tumor position up to 800 ms in advance. The predicted tumor position was compared to its observed position to establish the accuracy with which the filter could dynamically track tumor motion under nonstationary conditions. These results were compared to simplified linear versions of the filter. The two lung cancer patients exhibited complex respiratory behavior in which the correlation between surrogate marker and tumor position changed with each cycle of breathing. By automatically and continuously adjusting its parameters to the observations, the neural network achieved better tracking accuracy than the fixed and adaptive linear filters. Variability and instability in human respiration complicate the task of predicting tumor position from surrogate breathing signals. Our results show that adaptive signal-processing filters can provide more accurate tumor position estimates than simpler stationary filters when presented with nonstationary breathing motion.
journal_name
Med Physjournal_title
Medical physicsauthors
Isaksson M,Jalden J,Murphy MJdoi
10.1118/1.2134958subject
Has Abstractpub_date
2005-12-01 00:00:00pages
3801-9issue
12eissn
0094-2405issn
2473-4209journal_volume
32pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more sensitive to changes in radiological depths along the beam path than for photon fields. Respiratory motion can cause such changes for treatments sites like lung, liver...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2756602
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773866
更新日期:2013-02-01 00:00:00
abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2795832
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12477
更新日期:2017-10-01 00:00:00
abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944287
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964454
更新日期:2016-11-01 00:00:00
abstract::An applicator system for intraoperative radiation therapy has been fabricated which does not require physical docking with the accelerator. A dosimetric study has been completed which documents the properties of this system for a variety of electron beam energies, applicator sizes, collimator settings, both primary an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596338
更新日期:1989-09-01 00:00:00
abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595218
更新日期:1982-01-01 00:00:00
abstract::In this report we evaluate an image registration technique that can improve the information content of intraoperative image data by deformable matching of preoperative images. In this study, pretreatment 1.5 tesla (T) magnetic resonance (MR) images of the prostate are registered with 0.5 T intraoperative images. The m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1414009
更新日期:2001-12-01 00:00:00
abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2719363
更新日期:2007-05-01 00:00:00
abstract::DICOM format is the de facto standard for communications between therapeutic and diagnostic modalities. A plan generated by a treatment planning system (TPS) is often exported to DICOM format. BEAMnrc/DOSXYZnrc is a widely used Monte Carlo (MC) package for beam and dose simulations in radiotherapy. It has its own defi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740186
更新日期:2012-07-01 00:00:00
abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598306
更新日期:1998-07-01 00:00:00
abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597110
更新日期:1993-09-01 00:00:00
abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12066
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12615
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734820
更新日期:2012-06-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:High-intensity focused ultrasound (HIFU) has been investigated for ablative therapy and drug enhancement for gene therapy and chemotherapy. The aim of this work is to explore the feasibility of pulsed focused ultrasound (pFUS) for cancer therapy using an in vivo animal model. METHODS:A clinical HIFU system (In...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901352
更新日期:2014-12-01 00:00:00
abstract::An overall practical dosimetric study of a 10-MV photon beam produced by a Varian Clinac-18 linear accelerator is presented. In particular measurements were made to provide data which could be utilized in computerized dosage calculations using the concept of dividing the radiation beam into primary and scatter compone...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594311
更新日期:1977-03-01 00:00:00
abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1778837
更新日期:2004-09-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00
abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751251
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12742
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431573
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstructio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12692
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) is one of the most used imaging modalities for imaging both symptomatic and asymptomatic patients. However, because of the high demand for lower radiation dose during CT scans, the reconstructed image can suffer from noise and artifacts due to the trade-off between the image quality and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12523
更新日期:2017-10-01 00:00:00
abstract::The data from Meisberger et al. [Radiology 90, 953-957 (1968)] are often used as a basis for dose calculations in brachytherapy. In order to describe the absorbed dose in water around a brachytherapy point source, Meisberger provided a polynomial fit for different isotopes taking into account the effect of attenuation...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597583
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734936
更新日期:2012-06-01 00:00:00