Abstract:
:Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference phenomena in optics and is known as the Gibbs phenomenon in engineering. Present techniques to cope with this problem include filtering and regularization schemes based on minimum norm or maximum entropy constraints. In this paper, a new technique based on object modeling and estimation is developed to achieve superresolution reconstruction from partial Fourier transform data. The nonlinear parameters of the object model are obtained using the singular value decomposition (SVD)-based all-pole model framework, and the linear parameters are determined using a standard least squares estimation method. This technique is capable, in principle, of unlimited resolution and is robust with respect to Gaussian white noise perturbation to the measured data and with respect to systematic modeling errors. Reconstruction results from simulated data and real magnetic resonance data are presented to illustrate the performance of the proposed method.
journal_name
Med Physjournal_title
Medical physicsauthors
Haacke EM,Liang ZP,Izen SHdoi
10.1118/1.596427subject
Has Abstractpub_date
1989-05-01 00:00:00pages
388-97issue
3eissn
0094-2405issn
2473-4209journal_volume
16pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598228
更新日期:1998-04-01 00:00:00
abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198307
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:The primary feasibility steps of demonstrating the ability of microwave-induced thermoacoustic (TA) in phantoms have been previously reported. However, none were shown to target a diseased site in living subjects in thermoacoustic tomography (TAT) field so far. To determine the expressions of oncogenic surface ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3466696
更新日期:2010-08-01 00:00:00
abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735274
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The local depth dose gradient and the displacement correction factor for Farmer-type ionization chambers are quantified for reference dosimetry at shallow depth in single-layer scanned proton fields. METHOD:Integrated radial profiles as a function of depth (IRPDs) measured at three proton therapy centers were ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14554
更新日期:2020-12-01 00:00:00
abstract::Spectra, yields, average energies, and kerma rates in tissue of neutrons from 21-MeV deuteron bombardment of deuterium gas targets have been calculated for target thicknesses of 1, 3.5, and 5 MeV. A high pressure gas cell was constructed and was filled with 33 atm of D2 gas (equivalent to an energy loss of 3.5 MeV for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594561
更新日期:1979-05-01 00:00:00
abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594746
更新日期:1980-09-01 00:00:00
abstract:PURPOSE:In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not appl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3598442
更新日期:2011-07-01 00:00:00
abstract::The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-033 thin-window ionization chamber. The primary study was the polarity ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596072
更新日期:1987-03-01 00:00:00
abstract:PURPOSE:Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS:RCs were obtained from PET/CT measurements of seve...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12330
更新日期:2017-07-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00
abstract:PURPOSE:In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914158
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3495969
更新日期:2010-11-01 00:00:00
abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1408620
更新日期:2001-11-01 00:00:00
abstract::The authors describe a method for directly digitizing optical images with a photostimulable phosphor (PSP) system. A PSP plate is initially charged with an exposure to a uniform x-ray field, and is then exposed to an optical image which discharges the plate in relation to the amount of incident light. Two applications...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596917
更新日期:1992-07-01 00:00:00
abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615059
更新日期:2011-08-01 00:00:00
abstract::Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598159
更新日期:1997-05-01 00:00:00
abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2103447
更新日期:2005-11-01 00:00:00
abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597425
更新日期:1995-10-01 00:00:00
abstract::Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the na...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163247
更新日期:2006-02-01 00:00:00
abstract::A single-field rotational total skin electron irradiation technique has recently been developed at the McGill University for treatment of skin malignancies. The dose received by a given surface point during rotation in a uniform large electron field depends on the radius of rotation of the surface point, on the local ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595524
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14208
更新日期:2020-08-01 00:00:00
abstract::Computer algorithms for rotational therapy beams, in most cases, perform dose calculations by summing stored fixed beam data at finite angular steps. Such an algorithm, based on the Bentley beam model, was evaluated by comparing calculations with measured data for an 18-MV x-ray beam. Measurements were made in a speci...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595985
更新日期:1987-11-01 00:00:00
abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2335490
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14377
更新日期:2020-09-01 00:00:00
abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595508
更新日期:1984-05-01 00:00:00
abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735058
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. METHODS:Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4929555
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734654
更新日期:2012-06-01 00:00:00