Planning strategies in volumetric modulated are therapy for breast.

Abstract:

PURPOSE:In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated are therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. METHODS:RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (0) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. RESULTS:I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, Dv = 98% [%]= 92.5 +/- 0.9 and 68.5 +/- 3.1, respectively, for EO and OO. Minor changes were registered in organs at risk sparing for both EO and OO. III. From dose distributions and DVHs, EO approach allowed to irradiate at near to prescription levels also the expanded fraction of the target: this would account also for residual intrafraction movements. CONCLUSIONS:The proposed plan strategy could represent a robust approach to account for moderate changes in target or body volume during the course of breast radiotherapy and to account for residual intrafractional respiratory motion in volumetric modulated are therapy. The strategy, logistically simple to implement requiring only modifications to the standard planning workflow was routinely implemented at author's institute for treatment of breast patients with RapidArc.

journal_name

Med Phys

journal_title

Medical physics

authors

Giorgia N,Antonella F,Alessandro C,Eugenio V,Luca C

doi

10.1118/1.3598442

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

4025-31

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

38

pub_type

杂志文章
  • Electron backscatter corrections for parallel-plate chambers.

    abstract::The wall of an ionization chamber is commonly assumed to have a negligible effect on chamber response in electron beams. For cylindrical chambers with thin walls this assumption is valid. However, parallel-plate chambers commonly possess large mechanical supports which may affect chamber response in a manner not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596165

    authors: Hunt MA,Kutcher GJ,Buffa A

    更新日期:1988-01-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • Verification of IMRT dose distributions using a water beam imaging system.

    abstract::A water beam imaging system (WBIS) has been developed and used to verify dose distributions for intensity modulated radiotherapy using dynamic multileaf collimator. This system consisted of a water container, a scintillator screen, a charge-coupled device camera, and a portable personal computer. The scintillation ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1413519

    authors: Li JS,Boyer AL,Ma CM

    更新日期:2001-12-01 00:00:00

  • Carpal tunnel syndrome diagnosis by a self-normalization process and ultrasound compound imaging.

    abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767754

    authors: Liao YY,Wu CC,Kuo TT,Chen JP,Hsu YW,Yeh CK

    更新日期:2012-12-01 00:00:00

  • Fourier-based approach to interpolation in single-slice helical computed tomography.

    abstract::It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal dire...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350583

    authors: La Rivière PJ,Pan X

    更新日期:2001-03-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory.

    abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596166

    authors: Jette D

    更新日期:1988-03-01 00:00:00

  • The NMR blood flowmeter--applications.

    abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594989

    authors: Salles-Cunha SX,Halbach RE,Battocletti JH,Sances A Jr

    更新日期:1981-07-01 00:00:00

  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

    abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2739805

    authors: Liu X,Shaw CC

    更新日期:2007-07-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Smoothing intensity-modulated treatment delivery under hardware constraints.

    abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1521121

    authors: Ma L

    更新日期:2002-12-01 00:00:00

  • 3D modeling of effects of increased oxygenation and activity concentration in tumors treated with radionuclides and antiangiogenic drugs.

    abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615164

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2011-08-01 00:00:00

  • A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations.

    abstract:PURPOSE:To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. METHODS:A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932364

    authors: Li X,Shi JQ,Zhang D,Singh S,Padole A,Otrakji A,Kalra MK,Xu XG,Liu B

    更新日期:2015-11-01 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID.

    abstract:PURPOSE:The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. METHODS:The APS has an active area of 5.4 × 5.4 cm and maximum full frame read-out rate of 20 frame s(-1),...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651632

    authors: Osmond JP,Zin HM,Harris EJ,Lupica G,Allinson NM,Evans PM

    更新日期:2011-11-01 00:00:00

  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs.

    abstract::Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103Pd, 125I, and 131Cs radionuclides, respectively, were modeled and benchmarked against previously published ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2940604

    authors: Melhus CS,Rivard MJ

    更新日期:2008-07-01 00:00:00

  • Technical note: development of a tidal volume surrogate that replaces spirometry for physiological breathing monitoring in 4D CT.

    abstract:PURPOSE:Spirometry exhibits baseline drift and frequent measurement errors so it cannot be used by itself to provide tidal volume-based image sorting or breathing motion modeling. Other breathing surrogates, in this study an abdominal bellows system, are drift free but do not measure tidal volume. Simultaneously using ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284282

    authors: Werner R,White B,Handels H,Lu W,Low DA

    更新日期:2010-02-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • A new framework of image reconstruction from fan beam projections.

    abstract::In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577252

    authors: Chen GH

    更新日期:2003-06-01 00:00:00

  • Dependence of virtual wedge factor on dose calibration and monitor units.

    abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344204

    authors: Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg TH

    更新日期:2001-02-01 00:00:00

  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy.

    abstract:PURPOSE:To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. METHODS:The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12721

    authors: Rah JE,Shin D,Manger RP,Kim TH,Oh DH,Kim DY,Kim GY

    更新日期:2018-02-01 00:00:00

  • Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.

    abstract:PURPOSE:This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18-46.5 keV. METHODS:Pieces of XR-QA2 films were irradiated, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939063

    authors: Di Lillo F,Mettivier G,Sarno A,Tromba G,Tomic N,Devic S,Russo P

    更新日期:2016-01-01 00:00:00

  • Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies.

    abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664003

    authors: Konstantinidis AC,Olivo A,Speller RD

    更新日期:2011-12-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • DCE-MRI defined subvolumes of a brain metastatic lesion by principle component analysis and fuzzy-c-means clustering for response assessment of radiation therapy.

    abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4842556

    authors: Farjam R,Tsien CI,Lawrence TS,Cao Y

    更新日期:2014-01-01 00:00:00

  • Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

    abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3641874

    authors: Audet C,Poffenbarger BA,Chang P,Jackson PS,Lundahl RE,Ryu SI,Ray GR

    更新日期:2011-11-01 00:00:00

  • Effect of patient support pads on image quality and dose in fluoroscopy.

    abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597906

    authors: Geiser WR,Huda W,Gkanatsios NA

    更新日期:1997-03-01 00:00:00