Abstract:
:One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor units (MU), and beam tuning for a Primus, a linear accelerator with two dose-rate ranges available for VW operation. The VWF is defined as the ratio of doses measured on the beam central axis for the wedge field to the open field; the open field dose is always measured with the nominal high dose-rate beam. When VW operates in the high dose-rate range, the VWF is independent of calibration (cGy/MU). When VW works in the low dose-rate range, the VWF varies linearly with the calibration of the low dose-rate mode. For a linear accelerator that has only one dose-rate range for VW, there is no observable dependence of VWF on the calibration. We also studied the monitor unit dependence of VWF. A discontinuity in VWF was observed at the switching point between the high and low dose-rate ranges. Working with Siemens, we have investigated causes of this discontinuity. As a result of this investigation, the discontinuity in VWF as a function monitor unit is practically removed.
journal_name
Med Physjournal_title
Medical physicsauthors
Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg THdoi
10.1118/1.1344204subject
Has Abstractpub_date
2001-02-01 00:00:00pages
174-7issue
2eissn
0094-2405issn
2473-4209journal_volume
28pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1429238
更新日期:2002-02-01 00:00:00
abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1523932
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4933200
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735033
更新日期:2012-06-01 00:00:00
abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596026
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14186
更新日期:2020-08-01 00:00:00
abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2218314
更新日期:2006-08-01 00:00:00
abstract::Accelerator-based neutron source have been considered to be practical for boron neutron capture therapy (BNCT). Based on experience with a parameters of the Brookhaven National Laboratory BMRR reactor neutron source, which has been used in treatment experiments, the future accelerator-based neutron source for BNCT sho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598299
更新日期:1998-07-01 00:00:00
abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813299
更新日期:2013-08-01 00:00:00
abstract::A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with function...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596643
更新日期:1991-09-01 00:00:00
abstract:PURPOSE:Imaging the knee under realistic load-bearing conditions can be carried out in a horizontal plane using a C-arm CT scanner. Human subjects can be scanned in a standing position and acquired data successfully reconstructed. However, reconstructing this data is a challenge due to significant artifacts that are in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736213
更新日期:2012-06-01 00:00:00
abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965910
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3602456
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract::Two experimental methods are described for obtaining average energies of neutron spectra produced by an electron accelerator in a medical treatment room. In the first method, the dose equivalent is measured by means of indium activation foils in an Andersson-Braun moderator. Fluences are determined by the usual activa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595662
更新日期:1985-11-01 00:00:00
abstract:PURPOSE:Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and applies it, for the first time, in the concept of triple-energy CT (TECT)...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12933
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222872
更新日期:2009-10-01 00:00:00
abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2890391
更新日期:2008-05-01 00:00:00
abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12893
更新日期:2018-06-01 00:00:00
abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2207212
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903292
更新日期:2015-01-01 00:00:00
abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596292
更新日期:1988-01-01 00:00:00
abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3602459
更新日期:2011-10-01 00:00:00
abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596610
更新日期:1991-09-01 00:00:00
abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598277
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735724
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3515458
更新日期:2010-12-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00