Automated segmentation of lungs with severe interstitial lung disease in CT.

Abstract:

PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lungs with severe ILD in multidetector CT scans. METHODS:Our database consisted of 76 CT scans, including 31 normal cases and 45 abnormal cases with moderate or severe ILD. The lungs in three selected slices for each CT scan were first manually delineated by a medical physicist, and then confirmed or revised by an expert chest radiologist, and they were used as the reference standard for lung segmentation. To segment the lungs, we first employed a CT value thresholding technique to obtain an initial lung estimate, including normal and mild ILD lung parenchyma. We then used texture-feature images derived from the co-occurrence matrix to further identify abnormal lung regions with severe ILD. Finally, we combined the identified abnormal lung regions with the initial lungs to generate the final lung segmentation result. The overlap rate, volume agreement, mean absolute distance (MAD), and maximum absolute distance (dmax) between the automatically segmented lungs and the reference lungs were employed to evaluate the performance of the segmentation method. RESULTS:Our segmentation method achieved a mean overlap rate of 96.7%, a mean volume agreement of 98.5%, a mean MAD of 0.84 mm, and a mean dmax of 10.84 mm for all the cases in our database; a mean overlap rate of 97.7%, a mean volume agreement of 99.0%, a mean MAD of 0.66 mm, and a mean dmax of 9.59 mm for the 31 normal cases; and a mean overlap rate of 96.1%, a mean volume agreement of 98.1%, a mean MAD of 0.96 mm, and a mean dmax of 11.71 mm for the 45 abnormal cases with ILD. CONCLUSIONS:Our lung segmentation method provided accurate segmentation results for abnormal CT scans with severe ILD and would be useful for developing CAD systems for quantification, detection, and diagnosis of ILD.

journal_name

Med Phys

journal_title

Medical physics

authors

Wang J,Li F,Li Q

doi

10.1118/1.3222872

subject

Has Abstract

pub_date

2009-10-01 00:00:00

pages

4592-9

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

    abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939808

    authors: Ahmad SB,Sarfehnia A,Paudel MR,Kim A,Hissoiny S,Sahgal A,Keller B

    更新日期:2016-02-01 00:00:00

  • Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

    abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3537610

    authors: Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rd

    更新日期:2011-02-01 00:00:00

  • A filtering method for signal equalization in region-of-interest fluoroscopy.

    abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1470205

    authors: Robert N,Komljenovic PT,Rowlands JA

    更新日期:2002-05-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.

    abstract::The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3078045

    authors: De Beenhouwer J,Staelens S,Vandenberghe S,Verhaeghe J,Van Holen R,Rault E,Lemahieu I

    更新日期:2009-04-01 00:00:00

  • Comparison of breast density measured on MR images acquired using fat-suppressed versus nonfat-suppressed sequences.

    abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3646756

    authors: Chang DH,Chen JH,Lin M,Bahri S,Yu HJ,Mehta RS,Nie K,Hsiang DJ,Nalcioglu O,Su MY

    更新日期:2011-11-01 00:00:00

  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system.

    abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760774

    authors: Ford EC,Smith K,Harris K,Terezakis S

    更新日期:2012-11-01 00:00:00

  • Characteristics of an OSLD in the diagnostic energy range.

    abstract:PURPOSE:Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602456

    authors: Al-Senan RM,Hatab MR

    更新日期:2011-07-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.

    abstract::Stereotactic X-ray mammography (SM) and ultrasound (US) guidance are both commonly used for breast biopsy. While SM provides three-dimensional (3D) targeting information and US provides real-time guidance, both have limitations. SM is a long and uncomfortable procedure and the US guided procedure is inherently two dim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2794175

    authors: Surry KJ,Mills GR,Bevan K,Downey DB,Fenster A

    更新日期:2007-11-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking.

    abstract:PURPOSE:The spatial and temporal tracking performance of a commercially available 3D optical surface imaging system is evaluated for its potential use in frameless stereotactic radiosurgery head tracking applications. METHODS:Both 3D surface and infrared (IR) marker tracking were performed simultaneously on a head pha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823757

    authors: Wiersma RD,Tomarken SL,Grelewicz Z,Belcher AH,Kang H

    更新日期:2013-11-01 00:00:00

  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Localization of cochlear implant electrodes in radiographs.

    abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598940

    authors: Yang S,Wang G,Skinner MW,Rubinstein JT,Vannier MW

    更新日期:2000-04-01 00:00:00

  • A computer simulation of wavelet noise reduction in computed tomography.

    abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598654

    authors: Harpen MD

    更新日期:1999-08-01 00:00:00

  • SU-E-T-264: New Concrete Designed and Evaluation for Megavoltage X Radiotherapy Facilities (CONTEK-RFH2).

    abstract:PURPOSE:The most common material for shielding is concrete, which can be made using various materials of different densities as aggregates. New techniques in radiotherapy, as IMRT and VMAT, require more monitor units and it is important to develop specifically designed shielding materials. METHODS:Arraela S.L. has dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735331

    authors: Mera M,Pereira L,Mera M,Pereira L,Meilán E,Moral FD,Teijeiro A,Salgado M,Andrade B,Gomez F,Fuentes-Vázquez V,Caruncho J,Medina A

    更新日期:2012-06-01 00:00:00

  • Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.

    abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863510

    authors: Ren L,Wu D,Li Y,Wang G,Wu X,Liu H

    更新日期:2014-03-01 00:00:00

  • Dead time of an anger camera in dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows are sometimes employed in quantitative single photon emission computed tomography (SPECT) studies. The count-rate losses at high activities for a GE400AT camera were measured in such a dual-window-acquisition mode by imaging a decaying source composed of a hot sphere within a warm cylin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597008

    authors: Zasadny KR,Koral KF,Swailem FM

    更新日期:1993-07-01 00:00:00

  • SU-E-I-32: Sterile Radiation Reduction Gloves May Be Contraindicated in Fluoroscopically Guided Interventions.

    abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734747

    authors: Pasciak A,Neveu M,Sriharan A,Balius A,Jones A

    更新日期:2012-06-01 00:00:00

  • Effects of protocol and obesity on dose conversion factors in adult body CT.

    abstract:PURPOSE:In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients vary across scanner models, scan parameters, and patient size. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754584

    authors: Li X,Samei E,Williams CH,Segars WP,Tward DJ,Miller MI,Ratnanather JT,Paulson EK,Frush DP

    更新日期:2012-11-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • Reconstruction of electron spectra from depth doses with adaptive regularization.

    abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2161404

    authors: Wei J,Sandison GA,Chvetsov AV

    更新日期:2006-02-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00