Abstract:
PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpatient HU distribution variability. METHODS:The database consisted of 28 contrast-enhanced thoracic CT scans from different patients. For each scan, regions of interest were manually outlined within each of 13 tissues, including mesothelioma. For each tissue, the empirical percentiles in HU values were calculated along with the interpatient variability. The HU distributions of select tissues were compared across three different scanner and reconstruction filter/kernel combinations. RESULTS:The HU distributions of blood-containing tissues demonstrated substantial overlap, as did the HU distributions of pleural effusion, mesothelioma, muscle, and liver. The HU distribution of fat had the least overlap with the other tissues. Fat and muscle had the lowest interpatient HU variability and the narrowest HU distributions, while blood-containing tissues had the highest interpatient HU variability. A soft-tissue reconstruction filter/kernel yielded the narrowest HU distribution, and fat with artifact had the widest HU distribution. CONCLUSIONS:Characterization of tissues in CT scans enhances the understanding of those tissues' HU distributions. Due to their overlapping HU distributions and close spatial proximity to one another, separating pleural effusion, mesothelioma, muscle, and liver from one another is a difficult task based on HU value thresholding alone. The results illustrate the wide distributions and large variability that exist for tissues present in clinical thoracic CT scans.
journal_name
Med Physjournal_title
Medical physicsauthors
Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rddoi
10.1118/1.3537610subject
Has Abstractpub_date
2011-02-01 00:00:00pages
942-7issue
2eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR (192)Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4816673
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:Many biological objects, including neuronal dendrites, blood vasculature, airways, phylogenetic trees, produce tree structured data. Current methods of analysis either ignore the complex structure of trees or use distance-based methods which limit the scope of multivariate modeling. METHODS:We propose a branch...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12751
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:The recent introduction of digital tomosynthesis imaging into routine clinical use has enabled the acquisition of volumetric patient data within a standard radiographic examination. Tomosynthesis requires the acquisition of multiple projection views, requiring additional dose compared to a standard projection e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3250907
更新日期:2009-12-01 00:00:00
abstract::This paper investigates the effect of the waterproofing sleeve on the calibration of kilovoltage photon beams (50-300 kV). The sleeve effect correction factor, ps has been calculated using the Monte Carlo method as the ratios of the air kerma in an air cavity of a cylindrical chamber without the waterproofing sleeve t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598039
更新日期:1997-09-01 00:00:00
abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901551
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13102
更新日期:2018-07-25 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892606
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:To automatically and efficiently segment the lesion area of the colonoscopy polyp image, a polyp segmentation method has been presented. METHODS:An ensemble model of pretrained convolutional neural networks was proposed, using Unet-VGG, SegNet-VGG, and PSPNet. Firstly, the Unet-VGG is obtained by the first 10 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13865
更新日期:2019-12-01 00:00:00
abstract::A discussion of the thermodynamic aspects of a relatively new treatment method for giant cell tumors of the bone is presented in this paper. The advantages of implanting methylmethacrylate acrylic bone cement into a curetted tumor site are briefly discussed and placed in perspective relative to more prevalent surgical...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595902
更新日期:1986-03-01 00:00:00
abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4771958
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3538924
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916686
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4958960
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4821545
更新日期:2013-10-01 00:00:00
abstract::Two side-by-side energy windows, one at the photopeak and one at lower energy, are sometimes employed in quantitative SPECT studies. We measured the count-rate losses at moderately high activities of 131I for two multihead Anger cameras in such a dual-window-acquisition mode by imaging a decaying source composed of tw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598162
更新日期:1998-01-01 00:00:00
abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1576229
更新日期:2003-06-01 00:00:00
abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2992048
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:Our aim was to compare different magnet arrangements for magnetic cell delivery to human lower leg arteries and investigate the theoretical targeting efficiency under realistic flow conditions as a possible treatment after angioplasty. Additionally the potential of scaling down or translating the magnetic actua...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3593363
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4709605
更新日期:2012-06-01 00:00:00
abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598219
更新日期:1998-04-01 00:00:00
abstract:PURPOSE:To measure the calibration curves of EBT3 dosimetry films in photon and proton beams and to quantify the related uncertainties from one beam type to another. METHODS:EBT3 Gafchromic films have similar properties than EBT2 with a symmetric construction and a matte polyester substrate to prevent Newton's ring ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735176
更新日期:2012-06-01 00:00:00
abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595218
更新日期:1982-01-01 00:00:00
abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596487
更新日期:1990-05-01 00:00:00
abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740095
更新日期:2012-07-01 00:00:00
abstract::DICOM format is the de facto standard for communications between therapeutic and diagnostic modalities. A plan generated by a treatment planning system (TPS) is often exported to DICOM format. BEAMnrc/DOSXYZnrc is a widely used Monte Carlo (MC) package for beam and dose simulations in radiotherapy. It has its own defi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740186
更新日期:2012-07-01 00:00:00
abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595642
更新日期:1984-09-01 00:00:00
abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13116
更新日期:2018-10-01 00:00:00