Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles.

Abstract:

PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. The feasibility of a multipinhole, parallel, and converging collimator was investigated in a Monte Carlo study. METHODS:A cylindrical water phantom with 2 cm in diameter and 3 cm in height containing 0.5-2 mm diameter vials with 0.4%-1.6% AuNP concentrations was modelled by FLUKA. A 15 and 81 keV monoenergetic x-ray sheet beam of 0.4 mm in width was used to image the phantom with L-shell and K-shell XFCT, respectively, with a dose of 30 mGy. The collimator thickness for L-shell and K-shell data acquisition was 3.3 and 5.1 mm, respectively. The XFCT images resulting from three collimator geometries were generated using the maximum likelihood expectation maximization (MLEM) iterative reconstruction method. With a resolution of 0.4 mm they were corrected for x-ray attenuation. The sheet beam XFCT images were compared against pencil beam geometry images that were generated using 55 translations. To assess image quality, the contrast-to-noise ratio (CNR) was evaluated for each vial. The Rose criterion was used to determine the lowest AuNP concentration detectable for each image. RESULTS:Among the three collimator geometry types, the sheet beam L-shell and K-shell parallel collimator XFCT images yielded AuNP sensitivity limits at 0.09% and 0.08%, respectively, for a 2 mm diameter vial. The AuNP sensitivity limits of the pencil beam XFCT images were 0.07% and 0.01% for L-shell and K-shell XFCT, respectively. The L-shell parallel collimator AuNP imaging sensitivity approached that of the pencil beam geometry with a 55-fold reduction in imaging time. The AuNP sensitivity limits for the 1 mm diameter vial for the L-shell and K-shell parallel collimator XFCT images were 0.19% and 0.16%, respectively, and those of the pencil beam XFCT images were 0.08% and 0.01% for L-shell and K-shell XFCT, respectively. The remaining two collimator geometries resulted in a lower CNR and poorer image quality. For a 2 mm diameter vial, the AuNP sensitivity limits for the L-shell and K-shell multipinhole collimator XFCT images were 0.23% and 0.52%, respectively, while for the L-shell and K-shell converging collimator XFCT images the AuNP sensitivity limits were 0.38% and 0.13%, respectively. CONCLUSION:This work demonstrates the feasibility of sheet beam L-shell XFCT imaging for small animal studies using parallel-oriented lead collimators which can detect AuNP concentrations approaching the level of pencil beam images with reduced imaging time.

journal_name

Med Phys

journal_title

Medical physics

authors

Dunning CAS,Bazalova-Carter M

doi

10.1002/mp.12893

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

2572-2582

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Three-dimensional ultrasound system for guided breast brachytherapy.

    abstract::Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3243865

    authors: De Jean P,Beaulieu L,Fenster A

    更新日期:2009-11-01 00:00:00

  • On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.

    abstract::The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using ...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.1690712

    authors: Chan GH,Nath R,Williamson JF,American Association of Physicists in Medicine.

    更新日期:2004-05-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Image resolution of a microchannel plate x-ray image intensifier.

    abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594463

    authors: Gould RG

    更新日期:1978-01-01 00:00:00

  • Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

    abstract:PURPOSE:The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides exce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914860

    authors: Yang Y,Wang KK,Eslami S,Iordachita II,Patterson MS,Wong JW

    更新日期:2015-04-01 00:00:00

  • Wavelength dependence of the precision of noninvasive optical measurement of oxy-, deoxy-, and total-hemoglobin concentration.

    abstract::The precision of noninvasive optical measurement of the concentration changes in oxy-, deoxy-, and total-hemoglobin depends on wavelength. For estimating the precision, we calculated the noise level of the concentration changes as the uncertainty in measurements using several wavelength pairs of light. Seven laser dio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373401

    authors: Yamashita Y,Maki A,Koizumi H

    更新日期:2001-06-01 00:00:00

  • Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.

    abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14326

    authors: Son J,Shin D,Kim T,Park S,Rah JE

    更新日期:2020-09-01 00:00:00

  • A randomization approach to handling data scaling in nuclear medicine.

    abstract:PURPOSE:In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431573

    authors: Bai C,Conwell R,Kindem J

    更新日期:2010-06-01 00:00:00

  • 115In as a probe for the characterization of therapy bremsstrahlung beams and the detection of photoneutrons.

    abstract::Variation of the photoactivation rate across radiation fields of three different bremsstrahlung beams of two medical accelerators has been measured, making use of the photonuclear reactions in natural indium probes: 115In(y,y')115mIn and 115In(y,n)114mIn. The third nuclear reaction, 115In(n,y)116mIn, was used to detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598558

    authors: Krmar M,Slivka J,Bikit I,Conkić L,Rudić A

    更新日期:1999-04-01 00:00:00

  • Sensitivity of amorphous selenium to x rays from 40 kVp to 18 MV: measurements and implications for portal imaging.

    abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598219

    authors: Mah D,Rowlands JA,Rawlinson JA

    更新日期:1998-04-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Magnetic resonance spectroscopy.

    abstract::The nuclear magnetic resonance phenomenon has given rise to both magnetic resonance imaging, which yields morphologic data, and magnetic resonance spectroscopy (MRS), which yields chemical data. In humans these data are derived principally from the resonances of the hydrogen nucleus in the low molecular weight compoun...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2975225

    authors: Prost RW

    更新日期:2008-10-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R-CNN.

    abstract:PURPOSE:Automatic breast ultrasound (ABUS) imaging has become an essential tool in breast cancer diagnosis since it provides complementary information to other imaging modalities. Lesion segmentation on ABUS is a prerequisite step of breast cancer computer-aided diagnosis (CAD). This work aims to develop a deep learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14569

    authors: Lei Y,He X,Yao J,Wang T,Wang L,Li W,Curran WJ,Liu T,Xu D,Yang X

    更新日期:2020-10-30 00:00:00

  • Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and cyber-knife.

    abstract::A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1758351

    authors: Arakia F,Moribe N,Shimonobou T,Yamashita Y

    更新日期:2004-07-01 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Calculation of 131I-ortho-iodohippurate absorbed kidney dose: a literature review.

    abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594679

    authors: Flannery A,Veber J,Greenfield MA,McIntyre AB,Hamilton DR

    更新日期:1980-05-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • SU-E-I-38: Optimizing CT Slice Width Measurements.

    abstract:PURPOSE:For almost four decades bead and wire ramps have been used in the evaluation of slice width as part of QA testing for CT scanners. While each of these approaches have been recognized and accepted as reliable, in this paper we investigate the differences, advantages and limitations of these tools. Moreover, we s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734753

    authors: Marteinsdóttir M,Olafsdottir H,Fredriksson J,Andresson A,Healy A,Kristbjornsson A,Kristinsson S,Levy J,Goodenough D

    更新日期:2012-06-01 00:00:00

  • Dependence of virtual wedge factor on dose calibration and monitor units.

    abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344204

    authors: Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg TH

    更新日期:2001-02-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • In vitro in-stent restenoses evaluated by 3D ultrasound.

    abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3062944

    authors: Lécart M,Cardinal MH,Qin Z,Soulez G,Cloutier G

    更新日期:2009-02-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • Photon attenuation in computed tomography.

    abstract::The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594199

    authors: McCullough EC

    更新日期:1975-11-01 00:00:00

  • Segmentation of bone CT images and assessment of bone structure using measures of complexity.

    abstract::A nondestructive and noninvasive method for numeric characterization (quantification) of the structural composition of human bone tissue has been developed and tested. In order to quantify and to compare the structural composition of bones from 2D computed tomography (CT) images acquired at different skeletal location...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2336501

    authors: Saparin P,Thomsen JS,Kurths J,Beller G,Gowin W

    更新日期:2006-10-01 00:00:00

  • On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources.

    abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2239198

    authors: Mainegra-Hing E,Rogers DW

    更新日期:2006-09-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • First Measurements of Ionization Cluster-Size Distributions with a Compact Nanodosimeter.

    abstract:PURPOSE:A nanodosimeter is a type of detector which measures single ionizations in a small gaseous volume in order to obtain ionization cluster size probability distributions for characterization of radiation types. Working nanodosimeter detectors are usually bulky machines which require a lot of space. In this work, t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14738

    authors: Vasi F,Schneider U

    更新日期:2021-01-28 00:00:00

  • Dosimetric properties of the new 125I BrachySeed model LS-1 source.

    abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1445411

    authors: Chan GH,Prestwich WV

    更新日期:2002-02-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00