A unified material decomposition framework for quantitative dual- and triple-energy CT imaging.

Abstract:

PURPOSE:Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and applies it, for the first time, in the concept of triple-energy CT (TECT) for enhanced material differentiation and classification as well as dual-energy CT (DECT). METHODS:We express polychromatic projection into a linear combination of line integrals of material-selective images. The material decomposition is then turned into a problem of minimizing the least-squares difference between measured and estimated CT projections. The optimization problem is solved iteratively by updating the line integrals. The proposed technique is evaluated by using several numerical phantom measurements under different scanning protocols. The triple-energy data acquisition is implemented at the scales of micro-CT and clinical CT imaging with commercial "TwinBeam" dual-source DECT configuration and a fast kV switching DECT configuration. Material decomposition and quantitative comparison with a photon counting detector and with the presence of a bow-tie filter are also performed. RESULTS:The proposed method provides quantitative material- and energy-selective images examining realistic configurations for both DECT and TECT measurements. Compared to the polychromatic kV CT images, virtual monochromatic images show superior image quality. For the mouse phantom, quantitative measurements show that the differences between gadodiamide and iodine concentrations obtained using TECT and idealized photon counting CT (PCCT) are smaller than 8 and 1 mg/mL, respectively. TECT outperforms DECT for multicontrast CT imaging and is robust with respect to spectrum estimation. For the thorax phantom, the differences between the concentrations of the contrast map and the corresponding true reference values are smaller than 7 mg/mL for all of the realistic configurations. CONCLUSIONS:A unified framework for both DECT and TECT imaging has been established for the accurate extraction of material compositions using currently available commercial DECT configurations. The novel technique is promising to provide an urgently needed solution for several CT-based diagnostic and therapy applications, especially for the diagnosis of cardiovascular and abdominal diseases where multicontrast imaging is involved.

journal_name

Med Phys

journal_title

Medical physics

authors

Zhao W,Vernekohl D,Han F,Han B,Peng H,Yang Y,Xing L,Min JK

doi

10.1002/mp.12933

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

2964-2977

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Practical cone-beam lambda tomography.

    abstract::As a potentially important technology for medical x-ray computed tomography (CT), lambda tomography (LT) is to reconstruct a gradient-like image only from local projection data. Based on our recently derived exact fan-beam LT formula, [H. Y. Gu and G. Wang, Int. J. Biomed. Imaging 2006(1), 1-9 (2006)] here we propose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2348767

    authors: Yu H,Ye Y,Wang G

    更新日期:2006-10-01 00:00:00

  • Dose buildup for obliquely incident photon beams.

    abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596055

    authors: Gerbi BJ,Meigooni AS,Khan FM

    更新日期:1987-05-01 00:00:00

  • Evaluation of edge effect due to phase contrast imaging for mammography.

    abstract::It is well-known that the edge effect produced by phase contrast imaging results in the edge enhancement of x-ray images and thereby sharpens those images. It has recently been reported that phase contrast imaging using practical x-ray tubes with small focal spots has improved image sharpness as observed in the phase ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1992087

    authors: Matsuo S,Katafuchi T,Tohyama K,Morishita J,Yamada K,Fujita H

    更新日期:2005-08-01 00:00:00

  • The line spread function and modulation transfer function of a computed tomographic scanner.

    abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594283

    authors: Judy PF

    更新日期:1976-07-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943565

    authors: Hunter CR,Klein R,Beanlands RS,deKemp RA

    更新日期:2016-04-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • Eigencolor radiochromic film dosimetry.

    abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14742

    authors: Bouchard H,Billas I,Subie A,Duane S

    更新日期:2021-02-01 00:00:00

  • MLC quality assurance techniques for IMRT applications.

    abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1564091

    authors: Bayouth JE,Wendt D,Morrill SM

    更新日期:2003-05-01 00:00:00

  • SU-E-T-567: Improve Dose Conformity with IMRT Using Shorter Source to Tumor Distance.

    abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735656

    authors: Yang W,Sandler H,Fraass B

    更新日期:2012-06-01 00:00:00

  • Unequal weighting of given doses in opposed fields in treatment of cancer of the tonsillar region using 60Co, 4-, 8-, 15-, 24-MVp photons.

    abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594276

    authors: Wollin M,Gilbert HA,Kagan AR

    更新日期:1976-03-01 00:00:00

  • Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921997

    authors: Miller BW,Frost SH,Frayo SL,Kenoyer AL,Santos E,Jones JC,Green DJ,Hamlin DK,Wilbur DS,Fisher DR,Orozco JJ,Press OW,Pagel JM,Sandmaier BM

    更新日期:2015-07-01 00:00:00

  • A preclinical Talbot-Lau prototype for x-ray dark-field imaging of human-sized objects.

    abstract:PURPOSE:Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12889

    authors: Hauke C,Bartl P,Leghissa M,Ritschl L,Sutter SM,Weber T,Zeidler J,Freudenberger J,Mertelmeier T,Radicke M,Michel T,Anton G,Meinel FG,Baehr A,Auweter S,Bondesson D,Gaass T,Dinkel J,Reiser M,Hellbach K

    更新日期:2018-06-01 00:00:00

  • Influence of gold nanoparticles embedded in water on nanodosimetry for keV photon irradiation.

    abstract:PURPOSE:For the past two decades, high-Z nanoparticles have been of high interest to improve the therapeutic outcomes of radiation therapy, especially for low-energy X-rays. Monte Carlo (MC) simulations have been used to evaluate the boost of dose deposition induced by Auger electrons near the nanoparticle surface, by ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14576

    authors: Poignant F,Monini C,Testa É,Beuve M

    更新日期:2020-11-04 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • An outlook on x-ray CT research and development.

    abstract::Over the past decade, computed tomography (CT) theory, techniques and applications have undergone a rapid development. Since CT is so practical and useful, undoubtedly CT technology will continue advancing biomedical and non-biomedical applications. In this outlook article, we share our opinions on the research and de...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2836950

    authors: Wang G,Yu H,De Man B

    更新日期:2008-03-01 00:00:00

  • Comparisons of treatment optimization directly incorporating random patient setup uncertainty with a margin-based approach.

    abstract::The purpose of this study is to incorporate the dosimetric effect of random patient positioning uncertainties directly into a commercial treatment planning system's IMRT plan optimization algorithm through probabilistic treatment planning (PTP) and compare coverage of this method with margin-based planning. In this wo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3176940

    authors: Moore JA,Gordon JJ,Anscher MS,Siebers JV

    更新日期:2009-09-01 00:00:00

  • SU-E-I-16: Automated Liver Segmentation Method for CBCT Dataset by Probabilistic Atlas Construction.

    abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734730

    authors: Li D,Li H,Yin Y,Chen J

    更新日期:2012-06-01 00:00:00

  • Material-specific analysis using coherent-scatter imaging.

    abstract::Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1493216

    authors: Batchelar DL,Cunningham IA

    更新日期:2002-08-01 00:00:00

  • Application of the convolution method for calculation of output factors for therapy photon beams.

    abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596859

    authors: Ahnesjö A,Knöös T,Montelius A

    更新日期:1992-03-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Noise in stenosis measurement using digital subtraction angiography.

    abstract::This paper examines statistical errors in the measurement of arterial stenoses by digital videodensitometry. Images of vessel phantoms were acquired using digital subtraction angiographic techniques with low concentrations of an iodine contrast medium and low levels of x-ray exposure. Effects of the spatial and tempor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595652

    authors: Wright GA,Taylor KW,Rowlands JA

    更新日期:1985-11-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • Dynamic detector offsets for field of view extension in C-arm computed tomography with application to weight-bearing imaging.

    abstract:PURPOSE:In C-arm computed tomography (CT), the field of view (FOV) is often not sufficient to acquire certain anatomical structures, e.g., a full hip or thorax. Proposed methods to extend the FOV use a fixed detector displacement and a 360° scan range to double the radius of the FOV. These trajectories are designed for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4915542

    authors: Herbst M,Schebesch F,Berger M,Choi JH,Fahrig R,Hornegger J,Maier A

    更新日期:2015-05-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds.

    abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598971

    authors: Nath S,Chen Z,Yue N,Trumpore S,Peschel R

    更新日期:2000-05-01 00:00:00

  • Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM.

    abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930245

    authors: Price RG,Kadbi M,Kim J,Balter J,Chetty IJ,Glide-Hurst CK

    更新日期:2015-10-01 00:00:00

  • Intercomparison of methods for image quality characterization. I. Modulation transfer function.

    abstract::The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2188816

    authors: Samei E,Ranger NT,Dobbins JT 3rd,Chen Y

    更新日期:2006-05-01 00:00:00

  • Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    abstract:PURPOSE:X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12997

    authors: Vernekohl D,Tzoumas S,Zhao W,Xing L

    更新日期:2018-05-25 00:00:00

  • Designing an optical distance indicator for a radiation therapy accelerator.

    abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598510

    authors: Maughan RL

    更新日期:1999-02-01 00:00:00