Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy.

Abstract:

PURPOSE:To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. METHODS:The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine the steps that need focus for improving the patient-specific QA. The patient-specific range QA plans were selected according to seven treatment site groups, a total of 1437 cases. The process capability index, Cpm was used to guide the tolerance design of patient site-specific range. RESULTS:For prostate field, our results suggested that the patient range measurements were capable at the current tolerance level of ±1 mm in clinical proton plans. For other site-specific ranges, we analyzed that the tolerance tends to be overdesigned to insufficient process capability calculated by the patient-specific QA data. The customized tolerances were calculated for treatment sites. Control charts were constructed to simulate the patient QA time before and after the new tolerances were implemented. It is found that the total simulation QA time was decreased on average of approximately 20% after establishing new site-specific range tolerances. We simulated the financial impact of this project. The QA failure for whole process in proton therapy would lead up to approximately 30% increase in total cost. CONCLUSION:DMAIC framework can be used to provide an effective QA by setting customized tolerances. When tolerance design is customized, the quality is reasonably balanced with time and cost demands.

journal_name

Med Phys

journal_title

Medical physics

authors

Rah JE,Shin D,Manger RP,Kim TH,Oh DH,Kim DY,Kim GY

doi

10.1002/mp.12721

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

520-528

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.

    abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4705346

    authors: Chen X,Cvetkovic D,Ma CM,Chen L

    更新日期:2012-05-01 00:00:00

  • Impact of calibration methods for color medical displays on interpreting brain SPECT images.

    abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13532

    authors: Shibutani T,Onoguchi M,Yoneyama H,Nakajima K,Matsuo S,Bamba Y,Saito S

    更新日期:2019-06-01 00:00:00

  • MO-F-BRA-02: Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy.

    abstract:PURPOSE:To evaluate two deformable image registration (DIR) algorithms for the purpose of contour mapping to support image guided adaptive radiotherapy (IGART) with 4D cone beam CT (4DCBCT). METHODS:Eleven locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan- beam CT (4DFBCT) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735821

    authors: Balik S,Hugo G,Weiss E,Jan N,Roman N,Sleeman W,Fatyga M,Christensen G,Murphy M,Lu J,Keall P,Williamson J

    更新日期:2012-06-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • A method for characterizing and matching CT image quality across CT scanners from different manufacturers.

    abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12554

    authors: Winslow J,Zhang Y,Samei E

    更新日期:2017-11-01 00:00:00

  • Computer-aided detection of breast cancers using Haar-like features in automated 3D breast ultrasound.

    abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914162

    authors: Tan T,Mordang JJ,van Zelst J,Grivegnée A,Gubern-Mérida A,Melendez J,Mann RM,Zhang W,Platel B,Karssemeijer N

    更新日期:2015-04-01 00:00:00

  • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy.

    abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598930

    authors: Zavgorodni SF

    更新日期:2000-04-01 00:00:00

  • Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability.

    abstract:PURPOSE:The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. METHODS:A multisized imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923172

    authors: Solomon J,Wilson J,Samei E

    更新日期:2015-08-01 00:00:00

  • Analyzing the impact of intrafraction motion: correlation of different dose metrics with changes in target D95%.

    abstract:PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3605633

    authors: Waghorn BJ,Meeks SL,Langen KM

    更新日期:2011-08-01 00:00:00

  • DMLC tracking and gating can improve dose coverage for prostate VMAT.

    abstract:PURPOSE:To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. METHODS:A dose reconstruction method was used to retrospectively assess the dose d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892605

    authors: Colvill E,Poulsen PR,Booth JT,O'Brien RT,Ng JA,Keall PJ

    更新日期:2014-09-01 00:00:00

  • Quantum noise in detectors.

    abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595393

    authors: Rimkus D,Baily NA

    更新日期:1983-07-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Image noise and dose performance across a clinical population: Patient size adaptation as a metric of CT performance.

    abstract:PURPOSE:Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT per...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12172

    authors: Ria F,Wilson JM,Zhang Y,Samei E

    更新日期:2017-06-01 00:00:00

  • Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.

    abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3515458

    authors: Facure A,França WF

    更新日期:2010-12-01 00:00:00

  • A quality management program in intravascular brachytherapy.

    abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1524167

    authors: Chakri A,Thomadsen B

    更新日期:2002-12-01 00:00:00

  • Monte Carlo dose calculations in homogeneous media and at interfaces: a comparison between GEPTS, EGSnrc, MCNP, and measurements.

    abstract::Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1473134

    authors: Chibani O,Li XA

    更新日期:2002-05-01 00:00:00

  • Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy.

    abstract:PURPOSE:The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. METHODS:Balanced data according to the one-factor random effect model were assumed. RESULTS:Analysis-of-variance (anova)-based computation was ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4961397

    authors: Matsuo Y,Nakamura M,Mizowaki T,Hiraoka M

    更新日期:2016-09-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Current status and future perspective of flattening filter free photon beams.

    abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3554643

    authors: Georg D,Knöös T,McClean B

    更新日期:2011-03-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • Measurement of LINAC 90 degrees head leakage radiation TVL values.

    abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335489

    authors: Li Z,Mutic S,Low D

    更新日期:2006-09-01 00:00:00

  • Fourier transform infrared imaging and small angle x-ray scattering as a combined biomolecular approach to diagnosis of breast cancer.

    abstract::Fourier transform infrared (FTIR) microspectroscopic imaging and small angle x-ray scattering (SAXS) were combined to investigate the supramolecular structure of collagen from 27 tissue sections from patients undergoing mastectomy, excisional biopsy, or mammoplasty. Both techniques were correlated by matching the scat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2890391

    authors: Ooi GJ,Fox J,Siu K,Lewis R,Bambery KR,McNaughton D,Wood BR

    更新日期:2008-05-01 00:00:00

  • Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

    abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367279

    authors: Li XA

    更新日期:2001-05-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • Calibration of 192Ir high-dose-rate afterloading systems.

    abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596649

    authors: Goetsch SJ,Attix FH,Pearson DW,Thomadsen BR

    更新日期:1991-05-01 00:00:00

  • Metallic nanoparticles irradiated by low-energy protons for radiation therapy: Are there significant physical effects to enhance the dose delivery?

    abstract:PURPOSE:To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS:The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12362

    authors: Heuskin AC,Gallez B,Feron O,Martinive P,Michiels C,Lucas S

    更新日期:2017-08-01 00:00:00

  • Thermoacoustic molecular tomography with magnetic nanoparticle contrast agents for targeted tumor detection.

    abstract:PURPOSE:The primary feasibility steps of demonstrating the ability of microwave-induced thermoacoustic (TA) in phantoms have been previously reported. However, none were shown to target a diseased site in living subjects in thermoacoustic tomography (TAT) field so far. To determine the expressions of oncogenic surface ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3466696

    authors: Nie L,Ou Z,Yang S,Xing D

    更新日期:2010-08-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00