Abstract:
PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures may lead to different conclusions regarding the clinical impact of motion. This study compares the analysis of identical dose perturbations using different dosimetric metrics. Calculated changes in target D95% are used as a reference. METHODS:A total of 3768 motion-encoded dose distributions were calculated for nine lung tumor patients. The motion-encoded dose distributions were compared to static dose distributions using three dosimetric metrics: 2D gamma, 3D gamma, and histogram analysis. Each of these metrics was used to analyze dose perturbations both globally and within the target structure. Furthermore, the failing voxels were analyzed separately according to failure mode, i.e., under vs. over-dosed voxels. Metrics were evaluated based on their agreement with changes in target D95%. Evaluations included the metrics' maximum average sensitivity and specificity (MASS) in detecting unacceptable deliveries, a coefficient correlated to ranking (tau), and the linear correlation coefficient, r. RESULTS:Of the evaluated metrics, the histogram metric restricted to the under-dosed voxels within the target agreed best with changes in target D95%. This metric achieved a MASS of 0.93, a tau of 0.69, and an r-value of 0.85. In comparison, the unrestricted 2D gamma metric achieved MASS = 0.77, tau = 0.40, and r = 0.67. Restricting the 2D gamma test both geographically and in failure mode increased the MASS to 0.85, tau to 0.70, and the r-value to 0.80. CONCLUSIONS:This study suggests that any clinical decisions based solely on an unrestricted 2D gamma metric are suboptimal. A geographic and failure mode restriction can improve results. The remaining uncertainties with non-DVH (dose volume histogram) based metrics should be kept in mind when they are used to evaluate the dosimetric impact of target motion.
journal_name
Med Physjournal_title
Medical physicsauthors
Waghorn BJ,Meeks SL,Langen KMdoi
10.1118/1.3605633subject
Has Abstractpub_date
2011-08-01 00:00:00pages
4505-11issue
8eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918581
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Squamous cell carcinoma (SCC) is commonly treated by electron beam radiotherapy (EBRT) followed by a boost via brachytherapy. Considering the limitations associated with brachytherapy, in this study, a novel boosting technique in EBRT of lip carcinoma using an internal shield as an internal dose enhancer tool (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4795756
更新日期:2013-04-01 00:00:00
abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596302
更新日期:1988-03-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4722967
更新日期:2012-07-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595221
更新日期:1982-03-01 00:00:00
abstract:PURPOSE:To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. METHODS:A dose reconstruction method was used to retrospectively assess the dose d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892605
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accura...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13895
更新日期:2020-01-01 00:00:00
abstract::Depth dose characteristics of 24-MV beams from a medical linear accelerator at various SSDs have been measured. The dose buildup, percent depth dose (PDD), and output were measured using ionization chambers and a diode detector under full scatter. Surface dose ranged from 8% to 51% depending upon the collimator settin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596673
更新日期:1991-03-01 00:00:00
abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598374
更新日期:1998-10-01 00:00:00
abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2936229
更新日期:2008-07-01 00:00:00
abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594269
更新日期:1976-01-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate three-dimensional (3D) models for the diagnosis and treatmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868455
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4725172
更新日期:2012-07-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2791034
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939255
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Over the last four decades, Ocular Proton Therapy has been successfully used to treat patients affected by intraocular lesions. For this, treatment geometry verification is routinely performed using radiographic images to align a configuration of fiducial radiopaque markers implanted on the sclera outer surface...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12841
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4842556
更新日期:2014-01-01 00:00:00
abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002412
更新日期:2008-12-01 00:00:00
abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594877
更新日期:1981-11-01 00:00:00
abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1852791
更新日期:2005-02-01 00:00:00
abstract:PURPOSE:To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. METHODS:The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3560462
更新日期:2011-04-01 00:00:00
abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597218
更新日期:1994-11-01 00:00:00
abstract::The assessment of differential left and right lung function is important for patients under consideration for lung resection procedures such as single lung transplantation. We developed an automated, knowledge-based segmentation algorithm for purposes of deriving functional information from dynamic computed tomography...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598898
更新日期:2000-03-01 00:00:00
abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596761
更新日期:1992-09-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00