Abstract:
PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accuracy. To improve individual TLD tracking robustness, we developed an optical fingerprinting method to identify the TLD-100 chips. METHODS:Seven hundred and fifty-two images were initially captured using a digital microscope camera to build a feature library for both facets of 376 TLD-100 chips. A median intensity thresholding method was used to segment images into foreground and background. The affine transformation was used to register the segmented images to the same position. The fingerprint of each image was calculated from its registered image. All fingerprints were then recorded in an Elasticsearch® search database. The TLD fingerprint match was tested three times when the library was established and repeated once 20 months later. All chips were irradiated at 0, 1, 4, and 8 Gy on a calibrated clinical MV linac to establish the individual calibration curve. RESULTS:The true positive rate of identifying TLDs based on their optical fingerprints was 100% at initialization of the inventory. After 20 months and multiple deployments for characterization, calibration, and dose measurement, the true positive match rate dropped to 99% with zero false-positive matches. The TLDs exhibited high self-consistency in the dose-response test with R2 between 0.988 and 1 with linear regression. CONCLUSIONS:The TLD-100 chips surface textures are unique and sufficient to support accurate identification based on the optical fingerprinting. This method provides inexpensive and robust management of the TLDs for individual calibration and dosimetry.
journal_name
Med Physjournal_title
Medical physicsauthors
Shang D,Gu W,Landers A,Woods K,Yu V,Neph R,Tenn S,Sheng Kdoi
10.1002/mp.13895subject
Has Abstractpub_date
2020-01-01 00:00:00pages
267-271issue
1eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740174
更新日期:2012-07-01 00:00:00
abstract::When a catheter is inserted through an artery, the wall shear stress increases and the secondary flow exhibits an increased number of instantaneous vortices. These effects become more evident when the annular gap between the catheter and the artery becomes more narrow. Accordingly it is suggested that these factors ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596448
更新日期:1990-09-01 00:00:00
abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598259
更新日期:1998-05-01 00:00:00
abstract::Using high-energy photon and electron beams, the response of two solid water parallel-plate chambers is evaluated against a PTW (Physicallsch-Technische Werkstatten) Farmer-type chamber. These two chambers are (1) a Memorial "Holt" chamber which was further modified by this author to take advantage of electrically con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597074
更新日期:1993-03-01 00:00:00
abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1523932
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595221
更新日期:1982-03-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12629
更新日期:2017-12-01 00:00:00
abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13123
更新日期:2018-10-01 00:00:00
abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2937652
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817482
更新日期:2013-09-01 00:00:00
abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597511
更新日期:1995-07-01 00:00:00
abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752083
更新日期:2012-10-01 00:00:00
abstract::This study evaluates the effects of respiratory motion on breast radiotherapy delivered using segmented multileaf collimator (SMLC) intensity modulation. An anthropomorphic breast phantom was constructed of polystyrene plates between which radiographic films were inserted. The phantom was mounted on a moving platform ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2405323
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14471
更新日期:2020-11-01 00:00:00
abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596971
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736218
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13952
更新日期:2020-02-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597412
更新日期:1994-10-01 00:00:00
abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734794
更新日期:2012-06-01 00:00:00
abstract::Plaque rupture with superimposed thrombosis is the main cause of the acute coronary syndromes of unstable angina, myocardial infarction, and sudden death. Endothelial disruption leading to plaque rupture may relate to mechanical fatigue associated with cyclic flexion of plaques. A novel method is proposed to assess st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1593635
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:For the past two decades, high-Z nanoparticles have been of high interest to improve the therapeutic outcomes of radiation therapy, especially for low-energy X-rays. Monte Carlo (MC) simulations have been used to evaluate the boost of dose deposition induced by Auger electrons near the nanoparticle surface, by ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14576
更新日期:2020-11-04 00:00:00
abstract:PURPOSE:The quality of tomographic images is directly affected by the system model being used in image reconstruction. An accurate system matrix is desirable for high-resolution image reconstruction, but it often leads to high computation cost. In this work the authors present a maximum a posteriori reconstruction algo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284980
更新日期:2010-02-01 00:00:00
abstract::Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then recons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2074187
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:In this work the performance of a compact multiresolution and multicontrast x-ray phase system based on edge illumination is investigated. It has been designed for small animal imaging and with a limited footprint for ease of deployment in laboratories. METHODS:The presented edge illumination system is based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14553
更新日期:2020-10-27 00:00:00
abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...
journal_title:Medical physics
pub_type: 指南,杂志文章,实务指引,评审
doi:10.1118/1.1501822
更新日期:2002-09-01 00:00:00
abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1576229
更新日期:2003-06-01 00:00:00
abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12677
更新日期:2018-01-01 00:00:00